radioLicenseMaxCodeRate
CAMBIUM-PTP800-MIB ·
.1.3.6.1.4.1.17713.8.24.14
Object
scalar Integer32
Certain licensing authorities, for example FCC and Industry Canada, require adaptive modulation to be bound by a minimum and maximum modulation mode as defined by the radio license. This attribute is only of significance in such regions and when adaptive modulation is enabled. For other regions, for example ETSI, minimum and maximum modulation mode are directly adjustable by the user and are not defined by the radio license. In general, a modulation mode is defined by two aspects, a modulation and a code rate. This attribute is equal to 100 times the code rate aspect of the RadioLicenseMaxModMode attribute required by the radio license. For example, if RadioLicenseMaxModMode is configured for 256QAM 0.91, this attribute will read 91.
Context
- MIB
- CAMBIUM-PTP800-MIB
- OID
.1.3.6.1.4.1.17713.8.24.14- Type
- scalar
- Access
- readonly
- Status
- current
- Parent
- radioLicense
- Groups
- 1
Net-SNMP examples
How SNMP and these commands workScalars have one instance, identified by the .0 suffix.
Read the scalar instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'CAMBIUM-PTP800-MIB' -M '/opt/observium/mibs/cambium:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CAMBIUM-PTP800-MIB::radioLicenseMaxCodeRate.0'
More examples
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'CAMBIUM-PTP800-MIB' -M '/opt/observium/mibs/cambium:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'CAMBIUM-PTP800-MIB::radioLicenseMaxCodeRate'
Syntax
Integer32
Values & Constraints
Object Constraints
range: 0-100