cadCmRemoteQuerySourceIpAddr
CADANT-REMOTE-QUERY-MIB ·
.1.3.6.1.4.1.4998.1.1.55.1.1.8
Object
scalar
INET-ADDRESS-MIBInetAddress
The source IP address of the SNMP remote queries to the CMs. This value is changed from the Poller when the ifIndex of the cadSysSourceInterfaceRemoteQuery in the CADANT-CMTS-SYSTEM-MIB is changed due to using the cli command .. configure cable modem remote-query source-interface ..
Context
- MIB
- CADANT-REMOTE-QUERY-MIB
- OID
.1.3.6.1.4.1.4998.1.1.55.1.1.8- Type
- scalar
- Access
- readonly
- Status
- current
- Parent
- cadCmRemoteQueryPoller
Syntax
INET-ADDRESS-MIBInetAddress
Values & Constraints
No enumerated values or constraints recorded.