cadEnforceRulePenaltyDuration

CADANT-CMTS-MAC-MIB · .1.3.6.1.4.1.4998.1.1.20.2.30.2.1.6

Object

column r/w minutes Integer32
The duration of time (in minutes) that a monitored service flow is 
held in the penalty box after it has been found to be a Heavy User. 
Being placed in the penalty box implies that the service flow has 
had its Priority, Tmax, Tpeak, and Max Burst parameters within its 
QoS Parameter Set overridden by the corresponding values from the
Enforce Service Class Name. Values must be divisible by 30. 
The penalty duration must be an integer multiple of the sampling interval.

Context

MIB
CADANT-CMTS-MAC-MIB
OID
.1.3.6.1.4.1.4998.1.1.20.2.30.2.1.6
Type
column
Access
readwrite
Status
current
Units
minutes
Parent
cadEnforceRuleEntry
Table
cadEnforceRuleTable
Siblings
7

Syntax

minutes Integer32

Values & Constraints

Object Constraints
range: 30-10080

Related Objects

Sibling Objects