cadIfMacDomainRegRspToOverride
CADANT-CMTS-LAYER2CMTS-MIB ·
.1.3.6.1.4.1.4998.1.1.20.1.4.2.1.28
Object
column r/w
secondsUnsigned32
This attribute provides an ability to override the default value of the T6 timer in the CM. When this attribute is not set to its default value, then the CMTS will place it into the MDD and the CM MUST use this value in place of the default value for the T6 timer.
Context
- MIB
- CADANT-CMTS-LAYER2CMTS-MIB
- OID
.1.3.6.1.4.1.4998.1.1.20.1.4.2.1.28- Type
- column
- Access
- readwrite
- Status
- current
- Units
- seconds
- Parent
- cadIfMacDomainEntry
Net-SNMP examples
How SNMP and these commands workWalk the column to discover its indexed instances, or supply every index to read one instance.
Walk the column
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CADANT-CMTS-LAYER2CMTS-MIB' -M '/opt/observium/mibs/arris:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CADANT-CMTS-LAYER2CMTS-MIB::cadIfMacDomainRegRspToOverride'
More examples
Read one indexed instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'CADANT-CMTS-LAYER2CMTS-MIB' -M '/opt/observium/mibs/arris:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CADANT-CMTS-LAYER2CMTS-MIB::cadIfMacDomainRegRspToOverride.<cadIfMacDomainIfIndex>'
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'CADANT-CMTS-LAYER2CMTS-MIB' -M '/opt/observium/mibs/arris:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'CADANT-CMTS-LAYER2CMTS-MIB::cadIfMacDomainRegRspToOverride'
Syntax
secondsUnsigned32
Values & Constraints
Object Constraints
range: 1-255