cerSpareModeFaultId
CADANT-CMTS-EQUIPMENT-MIB ·
.1.3.6.1.4.1.4998.1.1.10.1.11.1.1.2
Object
column
Enumeration
The fault group associated with the override behavior.
When an event occurs that would normally trigger a card
reset and a sparing event and that event is in the configured
fault group, the mode configured in the cerCard table is
overriden.
pingFault - Communications failure with active controller
initTimeout - Timeout during card initialization
ersmFault - Card ERSM failure
swException - Software exception failure
bcm3142Err - Upstream CAM PHY device fatal fault condition
dulFailure - Upstream CAM periodic packet loop detected uncorrectable fault
dataplaneFailrue - Fatal errors originating in dataplane processor
dsUnderPower - Downstream CAM detected power on a connector is below operational threshold
dsOverPower - Downstream CAM detected power on a connector is above operational threshold
sbecOverflow - Excessive number of single bit ECC errors
deviceFatal - General device fatal error. For example in internal datapaths or pci controller.
fpgaFatalError - Fatal CRC errors detected in FPGA device
clockLost - Loss of clock or loss of clock lock
pwrSensorHighFault - Detected voltage is above operational threshold
pwrSensorLowFault - Detected voltage is below operational threshold
fpgaBufferPoolFault - Number of available buffers in MAC fpga is below threshold
dataplaneLinkFault - Card has lost dataplane connectivity
monitoredTaskFailure - Monitored software task has failed
Context
- MIB
- CADANT-CMTS-EQUIPMENT-MIB
- OID
.1.3.6.1.4.1.4998.1.1.10.1.11.1.1.2- Type
- column
- Access
- noaccess
- Status
- current
- Parent
- cerSpareModeExtEntry
- Table
- cerSpareModeExtTable
- Siblings
- 3
Syntax
Enumeration
Values & Constraints
Enumerated Values
0 | none |
1 | pingFault |
2 | initTimeout |
3 | ersmFault |
4 | swException |
5 | bcm3142Err |
6 | dulFailure |
7 | dataplaneFailure |
8 | dsUnderPower |
9 | dsOverPower |
10 | sbecOverflow |
11 | deviceFatal |
12 | fpgaFatalError |
13 | clockLost |
14 | pwrSensorHighFault |
15 | pwrSensorLowFault |
16 | fpgaBufferPoolFault |
17 | dataplaneLinkFault |
18 | monitoredTaskFailure |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| cerSpareModeCardId The cardId of the spare group leader for this override. | column | CADANT-TCCardId | .1.3.6.1.4.1.4998.1.1.10.1.11.1.1.1 |
| cerSpareModeMode The sparing mode that should be enforced when an error in the
configured catagory occurs that results in a sparing event. | column | Enumeration | .1.3.6.1.4.1.4998.1.1.10.1.11.1.1.3 |
| cerSpareModeRowStatus The only set actions supported on this table are
createAndGo(4) and destroy(6). | column | SNMPv2-TCRowStatus | .1.3.6.1.4.1.4998.1.1.10.1.11.1.1.4 |