cerCardSpareGroupMode
CADANT-CMTS-EQUIPMENT-MIB ·
.1.3.6.1.4.1.4998.1.1.10.1.4.12.1.25
Object
column
r/w
Enumeration
The admin mode of the spare group leader for this sparing group. This value will be set to the invalid card id for all cards not associated with a sparing group.
Context
- MIB
- CADANT-CMTS-EQUIPMENT-MIB
- OID
.1.3.6.1.4.1.4998.1.1.10.1.4.12.1.25- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- cerCardEntry
- Table
- cerCardTable
- Siblings
- 23
Syntax
Enumeration
Values & Constraints
Enumerated Values
0 | invalid |
1 | manual |
2 | auto |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| cerCardAdminState This is the administrative state of this card. | column | CADANT-TCAdminState | .1.3.6.1.4.1.4998.1.1.10.1.4.12.1.12 |
| cerCardPrState This is the primary state of this card. | column | CADANT-TCPrimaryState | .1.3.6.1.4.1.4998.1.1.10.1.4.12.1.13 |
| cerCardSecState This is the secondary state of this card. | column | CADANT-TCSecondaryState | .1.3.6.1.4.1.4998.1.1.10.1.4.12.1.14 |
| cerCardDplxStatus This is the duplexing status of this card. | column | CADANT-TCDuplexStatus | .1.3.6.1.4.1.4998.1.1.10.1.4.12.1.15 |
| cerCardAction Write-only action performed on this card. | column | CADANT-TCEqActionType | .1.3.6.1.4.1.4998.1.1.10.1.4.12.1.17 |
| cerCardTrapInh If a bit is set, the corresponding state change trap
will not be sent. | column | Bits | .1.3.6.1.4.1.4998.1.1.10.1.4.12.1.18 |
| cerCardNumPorts Number of ports this card contains. | column | Integer32 | .1.3.6.1.4.1.4998.1.1.10.1.4.12.1.19 |
| cerCardId The unique id of this card within the shelf. The
convention of cardId is as follows:
- Indices from 1 to 50 [1 - 50] are reserved for Circuit Packs.
In this case, the cardId is… | column | CADANT-TCCardId | .1.3.6.1.4.1.4998.1.1.10.1.4.12.1.2 |
| cerCardDetected CardType dectected automatically by the CMTS. | column | CADANT-TCCerCardType | .1.3.6.1.4.1.4998.1.1.10.1.4.12.1.20 |
| cerCardSubDetected CardSubType dectected automatically by the CMTS. | column | CADANT-TCCerCardSubType | .1.3.6.1.4.1.4998.1.1.10.1.4.12.1.21 |
| cerCardFwUpdateStatus Set to TRUE if a firmware update is in progress or has been done,
else set to FALSE. | column | SNMPv2-TCTruthValue | .1.3.6.1.4.1.4998.1.1.10.1.4.12.1.23 |
| cerCardSpareGroupId The cardId of the spare group leader for this sparing group.
This value will be set to the invalid card id for all cards not
associated with a sparing group. | column | CADANT-TCCardId | .1.3.6.1.4.1.4998.1.1.10.1.4.12.1.24 |
| cerCardUpTime The value of sysUpTime when the primary state for this card
made a transition from OOS to IS. | column | SNMPv2-SMITimeTicks | .1.3.6.1.4.1.4998.1.1.10.1.4.12.1.26 |
| cerCardTemperature The current relative temperature of the card. (1=coolest, 10=hottest) | column | Integer32 | .1.3.6.1.4.1.4998.1.1.10.1.4.12.1.29 |
| cerCardName This is the name of the card, if it has one. | column | OctetString | .1.3.6.1.4.1.4998.1.1.10.1.4.12.1.3 |
| cerCardType The type of card, if any. For example Ecard, Fcard, Dcard or Ucard
If the slot is empty, the value would be 'empty'. | column | CADANT-TCCerCardType | .1.3.6.1.4.1.4998.1.1.10.1.4.12.1.4 |
| cerCardPicDetected The type of PIC detected in this slot. | column | CADANT-TCCerPicType | .1.3.6.1.4.1.4998.1.1.10.1.4.12.1.40 |
| cerCardLastResetReason The reason for the latest card recovery. | column | OctetString | .1.3.6.1.4.1.4998.1.1.10.1.4.12.1.43 |
| cerCardTemperatureHighWarn The relative temperature of the card at which warnings are generated. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.4998.1.1.10.1.4.12.1.44 |
| cerCardTemperatureHighError The relative temperature of the card at which recoveries are initiated. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.4998.1.1.10.1.4.12.1.45 |
| cerCardAnnex The annex of the downstream channels associated with the card. | column | Enumeration | .1.3.6.1.4.1.4998.1.1.10.1.4.12.1.46 |
| cerCardNumRfConnectors Number of RF ports this card contains. | column | Integer32 | .1.3.6.1.4.1.4998.1.1.10.1.4.12.1.47 |
| cerCardSubType The cardType alone may not be specific enough to fully describe the
type of card that is in this slot. For example, a card type of Dcard
might have a more specific type of 1D8U w… | column | CADANT-TCCerCardSubType | .1.3.6.1.4.1.4998.1.1.10.1.4.12.1.5 |