xcvrAutoEnableTimer

BTI-7000-MIB · .1.3.6.1.4.1.18070.2.2.1.4.2.1.16

Object

Specifies the auto-enable timer for the targeted optical
transceiver. This value only applies if the xcvrAdminStatus
object is set to autoEnabled. Otherwise, the value returned is
000-00.

Context

MIB
BTI-7000-MIB
OID
.1.3.6.1.4.1.18070.2.2.1.4.2.1.16
Type
column
Access
readwrite
Status
current
Parent
xcvrEntry

Walk the column to discover its indexed instances, or supply every index to read one instance.

Walk the column
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'BTI-7000-MIB' -M '/opt/observium/mibs/bti:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'BTI-7000-MIB::xcvrAutoEnableTimer'
More examples
Read one indexed instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'BTI-7000-MIB' -M '/opt/observium/mibs/bti:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'BTI-7000-MIB::xcvrAutoEnableTimer.<index>'
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'BTI-7000-MIB' -M '/opt/observium/mibs/bti:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'BTI-7000-MIB::xcvrAutoEnableTimer'

Syntax

Values & Constraints

Type Constraints
range: 0..7