stmnBERTh

BTI-7000-MIB · .1.3.6.1.4.1.18070.2.2.1.4.7.1.12

Object

column r/w BTI-TC-MIBBERType
The Bit Error Rate threshold above which the Signal Degrade
condition is raised.

Context

MIB
BTI-7000-MIB
OID
.1.3.6.1.4.1.18070.2.2.1.4.7.1.12
Type
column
Access
readwrite
Status
current
Parent
stmnEntry

Walk the column to discover its indexed instances, or supply every index to read one instance.

Walk the column
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'BTI-7000-MIB' -M '/opt/observium/mibs/bti:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'BTI-7000-MIB::stmnBERTh'
More examples
Read one indexed instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'BTI-7000-MIB' -M '/opt/observium/mibs/bti:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'BTI-7000-MIB::stmnBERTh.<index>'
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'BTI-7000-MIB' -M '/opt/observium/mibs/bti:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'BTI-7000-MIB::stmnBERTh'

Syntax

Source
BTI-TC-MIBBERType
Base type
Enumeration

Values & Constraints

Object Constraints
range: 1-1 range: 11-11 range: 21-21 range: 31-31
Type Values
1none
2tenExpMinus9
3tenExpMinus8
4tenExpMinus7
5tenExpMinus6
6tenExpMinus5
7tenExpMinus4
8tenExpMinus3
9tenExpMinus10
10tenExpMinus11
11tenExpMinus12