ospfIfRtrDeadInterval

BTI-7000-MIB · .1.3.6.1.4.1.18070.2.2.1.13.3.1.13

Object

column r/w secondsInteger32
The number of seconds that a router's Hello packets have
not been seen before its neighbors declare the router down.
This should be some multiple of the Hello interval.  This
value must be the same for all routers attached to a common
network.

Context

MIB
BTI-7000-MIB
OID
.1.3.6.1.4.1.18070.2.2.1.13.3.1.13
Type
column
Access
readwrite
Status
current
Units
seconds
Parent
ospfIfEntry

Walk the column to discover its indexed instances, or supply every index to read one instance.

Walk the column
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'BTI-7000-MIB' -M '/opt/observium/mibs/bti:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'BTI-7000-MIB::ospfIfRtrDeadInterval'
More examples
Read one indexed instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'BTI-7000-MIB' -M '/opt/observium/mibs/bti:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'BTI-7000-MIB::ospfIfRtrDeadInterval.<ospfNbrIpAddr>.<ospfNbrAddressLessIndex>'
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'BTI-7000-MIB' -M '/opt/observium/mibs/bti:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'BTI-7000-MIB::ospfIfRtrDeadInterval'

Syntax

secondsInteger32

Values & Constraints

Object Constraints
range: 1-24