oaAmplifierConditioningCond

BTI-7000-MIB · .1.3.6.1.4.1.18070.2.2.2.2.6.0.25

Object

notification
There is an amplifier conditioning problem. When an amplifier
is initially plugged in, thermo-electric coolers (TEC) work to
control the pump laser temperature to between 16 degrees and
34 degrees Celsius. Until the pump laser temperature is within
range, the amplifier conditioning problem is present. If the
amplifier conditioning problem persists for more than 30
minutes, the condition is cleared and either a laser
temperature low threshold or a laser temperature high
threshold alarm is raised.