aniBsuWirelessPtPConfVerifyAllSu

BSUWIRELESSIF-MIB · .1.3.6.1.4.1.4325.3.2.10.12

Object

This flag is used to verify if the current set of BSU
wireless parameters, that is, 
aniBsuWirelessPtPConfChannelWidth,
aniBsuWirelessPtPConfTargetFrequency,
aniBsuWirelessPtPConfBsuId
are correctly configured on all the SUs connected.
The values are compared against all the SUs connected to this BSU.
          
Sending a Get request on this object causes the agent to verify
the above set of parameters. If these set of values are 
incorrect, an error string is returned indicating that some
values are not in sync. If the current set of values are
correct, then the string 'No error' is displayed.
          
This object might require upto 10 seconds to respond if multiple SUs 
are connected. Therefore, to ensure that it does not timeout before
getting the complete results, the SNMP Manager tool should increase
it's timeout value for this object to more than 10 seconds.

Context

MIB
BSUWIRELESSIF-MIB
OID
.1.3.6.1.4.1.4325.3.2.10.12
Type
scalar
Access
readonly
Status
current
Parent
aniBsuWirelessPtPConfGroup

Scalars have one instance, identified by the .0 suffix.

Read the scalar instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'BSUWIRELESSIF-MIB' -M '/opt/observium/mibs/aperto:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'BSUWIRELESSIF-MIB::aniBsuWirelessPtPConfVerifyAllSu.0'
More examples
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'BSUWIRELESSIF-MIB' -M '/opt/observium/mibs/aperto:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'BSUWIRELESSIF-MIB::aniBsuWirelessPtPConfVerifyAllSu'

Syntax

Source
SNMPv2-TCDisplayString
Base type
OctetString
Display format
255a
Type Description
Represents textual information taken from the NVT ASCII
          
character set, as defined in pages 4, 10-11 of RFC 854.
          
To summarize RFC 854, the NVT ASCII repertoire specifies:
          
  - the use of character codes 0-127 (decimal)
          
  - the graphics characters (32-126) are interpreted as
    US ASCII
          
  - NUL, LF, CR, BEL, BS, HT, VT and FF have the special
    meanings specified in RFC 854
          
  - the other 25 codes have no standard interpretation
          
  - the sequence 'CR LF' means newline
          
  - the sequence 'CR NUL' means carriage-return
          
  - an 'LF' not preceded by a 'CR' means moving to the
    same column on the next line.
          
  - the sequence 'CR x' for any x other than LF or NUL is
    illegal.  (Note that this also means that a string may
    end with either 'CR LF' or 'CR NUL', but not with CR.)
          
Any object defined using this syntax may not exceed 255
characters in length.

Values & Constraints

Type Constraints
range: 0..255