cmDsCalZeroIFCoefs

BRCM-CM-ENGINEERING-MIB · .1.3.6.1.4.1.4413.2.99.1.1.3.2.2.4

Object

scalar r/w SNMPv2-TCTruthValue
Setting this object to true(1) will result in all writable objects in
the cmDsCalIFCoefTable being set to zero.  Sets to false(2) will be
accepted, but will not result in any action being taken.  Reading
this object always returns false(2).

Context

MIB
BRCM-CM-ENGINEERING-MIB
OID
.1.3.6.1.4.1.4413.2.99.1.1.3.2.2.4
Type
scalar
Access
readwrite
Status
current
Parent
cmEngrDownstreamCalibration

Syntax

SNMPv2-TCTruthValue

Values & Constraints

Object Constraints
range: 0-100