BRCM-CM-ENGINEERING-MIB Table View
Table-centric layout grouping table, row, and column objects.
Tables
7
Rows
7
Columns
37
cmDsCalTunerCoefTable
table.1.3.6.1.4.1.4413.2.99.1.1.3.2.2.3
·
1 row entry
·
4 columns
Uses the broadcom variant from
Command help
/opt/observium/mibs/broadcom.
Walk cmDsCalTunerCoefTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'BRCM-CM-ENGINEERING-MIB' -M '/opt/observium/mibs/broadcom:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'BRCM-CM-ENGINEERING-MIB::cmDsCalTunerCoefTable'
A list of tuner coeffiencents to be used when calculating downstream power for this device.
An entry defining a tuner coefficient for a given frequency at the
given index for this device.
given index for this device.
| Column | Syntax | OID |
|---|---|---|
| cmDsCalTunerCoefIndexIdentifies the instance of this tuner coefficient. | Integer32 Constraints: range: 1-128 | .1.3.6.1.4.1.4413.2.99.1.1.3.2.2.3.1.1 |
| cmDsCalTunerCoefFrequencyThe downstream frequency at which this instance of cmDsCalTunerCoefValue applies. This read-only object is provided here for convenience. Value is identical to the value of the read-write object cmDsCalOffsetFrequenc… | hertzSNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.4413.2.99.1.1.3.2.2.3.1.2 |
| cmDsCalTunerCoefValueThe value of this tuner coefficient multiplied by one million. For example, a tuner coefficient value of 0.218369 would be represented as 218369. This gives a Since tuner coefficients must range in value between zero … | millionthUnsigned32r/w Constraints: range: 0-1000000 | .1.3.6.1.4.1.4413.2.99.1.1.3.2.2.3.1.3 |
| cmDsCalTunerCoefCopyFromSetting this object to the value of the first element of an index of a row in this table will cause all coefficients for this frequency to be copied from the corresponding location in the frequency pointed to by the in… | SNMPv2-SMIInteger32r/w Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.4413.2.99.1.1.3.2.2.3.1.4 |
cmDsCalIFCoefTable
table.1.3.6.1.4.1.4413.2.99.1.1.3.2.2.6
·
1 row entry
·
4 columns
Uses the broadcom variant from
Command help
/opt/observium/mibs/broadcom.
Walk cmDsCalIFCoefTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'BRCM-CM-ENGINEERING-MIB' -M '/opt/observium/mibs/broadcom:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'BRCM-CM-ENGINEERING-MIB::cmDsCalIFCoefTable'
A list of intermediate frequency coeffiencents to be used when calculating downstream power for this device.
An entry defining an IF coefficient for a given frequency at the
given index for this device.
given index for this device.
| Column | Syntax | OID |
|---|---|---|
| cmDsCalIFCoefIndexIdentifies the instance of this IF coefficient. | Integer32 Constraints: range: 1-128 | .1.3.6.1.4.1.4413.2.99.1.1.3.2.2.6.1.1 |
| cmDsCalIFCoefFrequencyThe downstream frequency at which this instance of cmDsCalIFCoefValue applies. This read-only object is provided here for convenience. Value is identical to the value of the read-write object cmDsCalOffsetFrequency w… | hertzSNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.4413.2.99.1.1.3.2.2.6.1.2 |
| cmDsCalIFCoefValueThe value of this IF coefficient multiplied by one hundred thousand. For example, an IF coefficent value of -2662.94 would be represented as -266294000. This gives an effective range of IF coefficent values ranging fro… | hundred-thousandthSNMPv2-SMIInteger32r/w Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.4413.2.99.1.1.3.2.2.6.1.3 |
| cmDsCalIFCoefCopyFromSetting this object to the value of the first element of an index of a row in this table will cause all coefficients for this frequency to be copied from the corresponding location in the frequency pointed to by the in… | SNMPv2-SMIInteger32r/w Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.4413.2.99.1.1.3.2.2.6.1.4 |
cmDsCalFineCoefTable
table.1.3.6.1.4.1.4413.2.99.1.1.3.2.2.9
·
1 row entry
·
4 columns
Uses the broadcom variant from
Command help
/opt/observium/mibs/broadcom.
Walk cmDsCalFineCoefTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'BRCM-CM-ENGINEERING-MIB' -M '/opt/observium/mibs/broadcom:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'BRCM-CM-ENGINEERING-MIB::cmDsCalFineCoefTable'
A list of Fine coeffiencents to be used when calculating downstream power for this device.
An entry defining a Fine coefficient for a given frequency at the
given index for this device.
given index for this device.
| Column | Syntax | OID |
|---|---|---|
| cmDsCalFineCoefIndexIdentifies the instance of this Fine coefficient. | Integer32 Constraints: range: 1-128 | .1.3.6.1.4.1.4413.2.99.1.1.3.2.2.9.1.1 |
| cmDsCalFineCoefFrequencyThe downstream frequency at which this instance of cmDsCalFineCoefValue applies. This read-only object is provided here for convenience. Value is identical to the value of the read-write object cmDsCalOffsetFrequency… | hertzSNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.4413.2.99.1.1.3.2.2.9.1.2 |
| cmDsCalFineCoefValueThe value of this fine coefficient multiplied by one million. For example, a fine coefficent value of 36.5494 would be represented as 36549400. This gives an effective range of fine coefficent values ranging from -2147… | millionthSNMPv2-SMIInteger32r/w Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.4413.2.99.1.1.3.2.2.9.1.3 |
| cmDsCalFineCoefCopyFromSetting this object to the value of the first element of an index of a row in this table will cause all coefficients for this frequency to be copied from the corresponding location in the frequency pointed to by the in… | SNMPv2-SMIInteger32r/w Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.4413.2.99.1.1.3.2.2.9.1.4 |
cmDsCalEqCoefTable
table.1.3.6.1.4.1.4413.2.99.1.1.3.2.2.12
·
1 row entry
·
4 columns
Uses the broadcom variant from
Command help
/opt/observium/mibs/broadcom.
Walk cmDsCalEqCoefTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'BRCM-CM-ENGINEERING-MIB' -M '/opt/observium/mibs/broadcom:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'BRCM-CM-ENGINEERING-MIB::cmDsCalEqCoefTable'
A list of equalizer coeffiencents to be used when calculating downstream power for this device.
An entry defining a equalizer coefficient for a given frequency at the
given index for this device.
given index for this device.
| Column | Syntax | OID |
|---|---|---|
| cmDsCalEqCoefIndexIdentifies the instance of this equalizer coefficient. | Integer32 Constraints: range: 1-128 | .1.3.6.1.4.1.4413.2.99.1.1.3.2.2.12.1.1 |
| cmDsCalEqCoefFrequencyThe downstream frequency at which this instance of cmDsCalEqCoefValue applies. This read-only object is provided here for convenience. Value is identical to the value of the read-write object cmDsCalOffsetFrequency w… | hertzSNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.4413.2.99.1.1.3.2.2.12.1.2 |
| cmDsCalEqCoefValueThe value of this equalizer coefficient multiplied by one hundred thousand. For example, an equalizer coefficent value of 4287.95 would be represented as 428795000. This gives an effective range of equalizer coeffic… | hundred-thousandthSNMPv2-SMIInteger32r/w Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.4413.2.99.1.1.3.2.2.12.1.3 |
| cmDsCalEqCoefCopyFromSetting this object to the value of the first element of an index of a row in this table will cause all coefficients for this frequency to be copied from the corresponding location in the frequency pointed to by the in… | SNMPv2-SMIInteger32r/w Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.4413.2.99.1.1.3.2.2.12.1.4 |
cmDsCalTunerTable
table.1.3.6.1.4.1.4413.2.99.1.1.3.2.2.32
·
1 row entry
·
5 columns
Uses the broadcom variant from
Command help
/opt/observium/mibs/broadcom.
Walk cmDsCalTunerTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'BRCM-CM-ENGINEERING-MIB' -M '/opt/observium/mibs/broadcom:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'BRCM-CM-ENGINEERING-MIB::cmDsCalTunerTable'
A table used to control all tuners present on this device.
An entry used to control an individual tuner.
Indexes
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
| cmDsCalTunerIndexIdentifies the instance of this tuner. | Integer32 Constraints: range: 1-8 | .1.3.6.1.4.1.4413.2.99.1.1.3.2.2.32.1.1 | ||||
| cmDsCalTunerTypeIdentifies the type of this tuner. | Enumeration | .1.3.6.1.4.1.4413.2.99.1.1.3.2.2.32.1.2 | ||||
| cmDsCalTunerNumChannelsIdentifies the maximum number of downstream channels which may be tuned by this tuner in this application. Note that the value of this object depends on the annex mode, because in Annex A each channel is 8MHz in widt… | Integer32 Constraints: range: 1-5 | .1.3.6.1.4.1.4413.2.99.1.1.3.2.2.32.1.3 | ||||
| cmDsCalTunerFrequencyThe center frequency to which this tuner will tune when cmDsCalTunerTuneNow is set to true(1). Note that a read of this object does NOT necessarily indicate that the CM is currently tuned to the indicated frequency,… | hertzInteger32r/w Constraints: range: 0-1000000000 | .1.3.6.1.4.1.4413.2.99.1.1.3.2.2.32.1.4 | ||||
| cmDsCalTunerTuneNowWhen this object is set to true(1), the tuner will tune to the frequency specified by cmDsCalTunerFrequency. Sets to false(2) will be rejected with an inconsistentValue error. taken. When read, this object returns tru… | SNMPv2-TCTruthValuer/w Type Values:
Description: Represents a boolean value. | .1.3.6.1.4.1.4413.2.99.1.1.3.2.2.32.1.5 |
cmDsCalPhyTable
table.1.3.6.1.4.1.4413.2.99.1.1.3.2.2.33
·
1 row entry
·
12 columns
Uses the broadcom variant from
Command help
/opt/observium/mibs/broadcom.
Walk cmDsCalPhyTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'BRCM-CM-ENGINEERING-MIB' -M '/opt/observium/mibs/broadcom:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'BRCM-CM-ENGINEERING-MIB::cmDsCalPhyTable'
A table which allows control over each individual downstream phy block present on the device.
An entry allowing control over an individual downstream phy block.
Indexes
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
| cmDsCalPhyIndexIdentifies the instance of this phy block. | Integer32 Constraints: range: 1-12 | .1.3.6.1.4.1.4413.2.99.1.1.3.2.2.33.1.1 | ||||
| cmDsCalPhyTunerControls which tuner from the cmDsCalTunerTable this phy is mapped to. | Integer32r/w Constraints: range: 1-8 | .1.3.6.1.4.1.4413.2.99.1.1.3.2.2.33.1.2 | ||||
| cmDsCalPhyTunerChannelControls which channel of the tuner identified by cmDsCalPhyTuner is mapped to this phy. Values are defined as offsets from the center channel of the tuner, which is represented by a value of 0 for this object. Note… | Integer32r/w Constraints: range: -8-8 | .1.3.6.1.4.1.4413.2.99.1.1.3.2.2.33.1.3 | ||||
| cmDsCalPhyModulationThe modulation type that the CM will attempt to lock under when cmDsCalPhyLockNow is set to true. Note that a read of this object does NOT necessarily indicate that the CM is currently locked under the indicated modul… | Enumerationr/w | .1.3.6.1.4.1.4413.2.99.1.1.3.2.2.33.1.4 | ||||
| cmDsCalPhyLockNowWhen this object is set to true(1), the CM will attempt to lock the downstream phy according to the parameters specified by the values of cmDsCalTunerCenterFrequency, cmDsCalPhyTuner, cmDsCalPhyTunerChannel, and cmDsCa… | SNMPv2-TCTruthValuer/w Type Values:
Description: Represents a boolean value. | .1.3.6.1.4.1.4413.2.99.1.1.3.2.2.33.1.5 | ||||
| cmDsCalPhyQamLockedIndicates whether the last set of cmDsCalPhyLockNow to true resulted in the phy acheiving QAM lock. The value of this object is reset whenever cmDsCalPhyLockNow is set to true, and its value will always indicate the… | SNMPv2-TCTruthValue Type Values:
Description: Represents a boolean value. | .1.3.6.1.4.1.4413.2.99.1.1.3.2.2.33.1.6 | ||||
| cmDsCalPhyFecLockedIndicates whether the last set of cmDsCalPhyLockNow to true resulted in the phy acheiving FEC lock. The value of this object is reset whenever cmDsCalPhyLockNow is set to true, and its value will always indicate the… | SNMPv2-TCTruthValue Type Values:
Description: Represents a boolean value. | .1.3.6.1.4.1.4413.2.99.1.1.3.2.2.33.1.7 | ||||
| cmDsCalPhySignalNoiseSignal/Noise ratio as perceived for this phy. | TenthdBDOCS-IF-MIBTenthdB | .1.3.6.1.4.1.4413.2.99.1.1.3.2.2.33.1.8 | ||||
| cmDsCalPhyPowerThe received power level for this phy. | dBmVDOCS-IF-MIBTenthdBmV | .1.3.6.1.4.1.4413.2.99.1.1.3.2.2.33.1.9 | ||||
| cmDsCalPhyFrequencyReports the frequency to which this phy is locked. The value of this object will reflect the frequency as calculated according to the settings of cmDsCalPhyTuner and cmDsCalPhyTuner, and does not include the frequenc… | hertzSNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.4413.2.99.1.1.3.2.2.33.1.10 | ||||
| cmDsCalPhyFrequencyErrorReports the frequency error for this phy. The actual frequency to which the phy is locked will be the sum of the value of this object and cmDsCalPhyFrequency. If cmDsCalPhyLockNow has not been set to true(1) then th… | hertzSNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.4413.2.99.1.1.3.2.2.33.1.11 | ||||
| cmDsCalPhySymbolRateReports the downstream symbol rate for this phy. If cmDsCalPhyLockNow has not been set to true(1) then this object will report a value of 0. | symbols per secondSNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.4413.2.99.1.1.3.2.2.33.1.12 |
cmUsCalControlTable
table.1.3.6.1.4.1.4413.2.99.1.1.3.2.3.5
·
1 row entry
·
4 columns
Uses the broadcom variant from
Command help
/opt/observium/mibs/broadcom.
Walk cmUsCalControlTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'BRCM-CM-ENGINEERING-MIB' -M '/opt/observium/mibs/broadcom:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'BRCM-CM-ENGINEERING-MIB::cmUsCalControlTable'
A list of control values to be used when calculating upstream power for this device.
An entry defining the control values for a given power at the given
index for this device.
index for this device.
Indexes
| Column | Syntax | OID |
|---|---|---|
| cmUsCalControlIndexIdentifies the instance of this pair of control values. | Integer32 Constraints: range: 1-128 | .1.3.6.1.4.1.4413.2.99.1.1.3.2.3.5.1.1 |
| cmUsCalControlPowerIndicates the upstream power level which is expected when the amp gain and DAC attenuation are programmed as indicated in this entry. This value is read-only, its value depends on the values set in cmUsCalControlStartP… | hundredth dBmVInteger32 Constraints: range: 0-255 | .1.3.6.1.4.1.4413.2.99.1.1.3.2.3.5.1.2 |
| cmUsCalControlAmpGainControls and reflects the amplifier gain setting used to produce an output power equal to the value of this entry's instance of cmUsCalControlPower. | Unsigned32r/w Constraints: range: 0-255 | .1.3.6.1.4.1.4413.2.99.1.1.3.2.3.5.1.3 |
| cmUsCalControlDacAttenControls and reflects the DAC attenuation setting used to produce an output power equal to the value of this entry's instance of cmUsCalControlPower. | Unsigned32r/w Constraints: range: 0-255 | .1.3.6.1.4.1.4413.2.99.1.1.3.2.3.5.1.4 |