battChargerInputVoltage
BRCM-BATTERY-MGMT-MIB ·
.1.3.6.1.4.1.4413.2.2.2.1.10.2.3
Object
scalar millivoltsSNMPv2-SMIUnsigned32
The most recently measured input voltage to the battery charger. Typically, if operating on battery power, this value will approach zero. If operating on utility power, this value will approach the value of the power supplied to the device.
Context
- MIB
- BRCM-BATTERY-MGMT-MIB
- OID
.1.3.6.1.4.1.4413.2.2.2.1.10.2.3- Type
- scalar
- Access
- readonly
- Status
- current
- Units
- millivolts
- Parent
- batteryCharger
Net-SNMP examples
How SNMP and these commands workScalars have one instance, identified by the .0 suffix.
Read the scalar instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'BRCM-BATTERY-MGMT-MIB' -M '/opt/observium/mibs/broadcom:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'BRCM-BATTERY-MGMT-MIB::battChargerInputVoltage.0'
More examples
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'BRCM-BATTERY-MGMT-MIB' -M '/opt/observium/mibs/broadcom:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'BRCM-BATTERY-MGMT-MIB::battChargerInputVoltage'
Syntax
millivoltsSNMPv2-SMIUnsigned32
- Source
- SNMPv2-SMIUnsigned32
- Base type
Unsigned32
Values & Constraints
Type Constraints
range: 0..4294967295