xoiIfBrkSeqVar

BIANCA-BRICK-X25-MIB · .1.3.6.1.4.1.272.4.6.15.1.25

Object

column mandatory r/w Integer32
This object indicates the additional number of startbits to detect
a break sequence send from V.110 terminal over an S2M interface.
The default number of startbits is 22, you can vary this value 
in range from 12 to 32, configuring here -10 to 10.

Context

MIB
BIANCA-BRICK-X25-MIB
OID
.1.3.6.1.4.1.272.4.6.15.1.25
Type
column
Access
readwrite
Status
mandatory
Parent
x25OverIsdnIfEntry

Walk the column to discover its indexed instances, or supply every index to read one instance.

Walk the column
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'BIANCA-BRICK-X25-MIB' -M '/opt/observium/mibs/bintec:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'BIANCA-BRICK-X25-MIB::xoiIfBrkSeqVar'
More examples
Read one indexed instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'BIANCA-BRICK-X25-MIB' -M '/opt/observium/mibs/bintec:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'BIANCA-BRICK-X25-MIB::xoiIfBrkSeqVar.<xoiIfIndex>'
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'BIANCA-BRICK-X25-MIB' -M '/opt/observium/mibs/bintec:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'BIANCA-BRICK-X25-MIB::xoiIfBrkSeqVar'

Syntax

Integer32

Values & Constraints

Object Constraints
range: -10-10