imaGroupErrorIntervalLinkUp

BIANCA-BRICK-IMA-MIB · .0.1.1.28

Object

column r/w Integer32
This indicates the duration of the measure interval in
seconds for the ATM header error counter. That is used 
for calculating an average, which is then compared with the 
imaGroupErrorsLinkUp value.

Context

MIB
BIANCA-BRICK-IMA-MIB
OID
.0.1.1.28
Type
column
Access
readwrite
Status
current
Parent
imaGroupEntry

Walk the column to discover its indexed instances, or supply every index to read one instance.

Walk the column
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'BIANCA-BRICK-IMA-MIB' -M '/opt/observium/mibs/bintec:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'BIANCA-BRICK-IMA-MIB::imaGroupErrorIntervalLinkUp'
More examples
Read one indexed instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'BIANCA-BRICK-IMA-MIB' -M '/opt/observium/mibs/bintec:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'BIANCA-BRICK-IMA-MIB::imaGroupErrorIntervalLinkUp.<imaGroupIndex>'
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'BIANCA-BRICK-IMA-MIB' -M '/opt/observium/mibs/bintec:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'BIANCA-BRICK-IMA-MIB::imaGroupErrorIntervalLinkUp'

Syntax

Integer32

Values & Constraints

Object Constraints
range: 15-3600