BIANCA-BRICK-IMA-MIB Table View
Table-centric layout grouping table, row, and column objects.
Tables
1
Rows
1
Columns
14
imaGroupTable
table.0.1
·
1 row entry
·
14 columns
Uses the bintec variant from
Command help
/opt/observium/mibs/bintec.
Walk imaGroupTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'BIANCA-BRICK-IMA-MIB' -M '/opt/observium/mibs/bintec:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'BIANCA-BRICK-IMA-MIB::imaGroupTable'
The IMA Group Configuration table.
An entry in the IMA Group table.
Indexes
| Column | Syntax | OID | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| imaGroupIndexA unique value for the IMA Group. | Integer32 Constraints: range: 1-2147483647 | .0.1.1.1 | ||||||||
| imaGroupSymmetrySymmetry of the IMA group. | ImaGroupSymmetryr/w Type Values:
| .0.1.1.7 | ||||||||
| imaGroupMinNumTxLinksMinimum number of transmit links required to be Active for the IMA group to be in the Operational state. | Integer32r/w Constraints: range: 1-32 | .0.1.1.8 | ||||||||
| imaGroupMinNumRxLinksMinimum number of receive links required to be Active for the IMA group to be in the Operational state. | Integer32r/w Constraints: range: 1-32 | .0.1.1.9 | ||||||||
| imaGroupTxFrameLengthThe frame length to be used by the IMA group in the transmit direction. Can only be set when the IMA group is startup. | ImaFrameLengthr/w Type Values:
| .0.1.1.17 | ||||||||
| imaGroupDiffDelayMaxThe maximum number of milliseconds of differential delay among the links that will be tolerated on this interface. | MilliSecondsr/w | .0.1.1.19 | ||||||||
| imaGroupAlphaValueThis indicates the 'alpha' value used to specify the number of consecutive invalid ICP cells to be detected before moving to the IMA Hunt state from the IMA Sync state. | Integer32r/w Constraints: range: 1-2 | .0.1.1.22 | ||||||||
| imaGroupBetaValueThis indicates the 'beta' value used to specify the number of consecutive errored ICP cells to be detected before moving to the IMA Hunt state from the IMA Sync state. | Integer32r/w Constraints: range: 1-5 | .0.1.1.23 | ||||||||
| imaGroupGammaValueThis indicates the 'gamma' value used to specify the number of consecutive valid ICP cells to be detected before moving to the IMA Sync state from the IMA PreSync state. | Integer32r/w Constraints: range: 1-5 | .0.1.1.24 | ||||||||
| imaGroupErrorsLinkDownThis indicates the threshold of the number of ATM header errors per 100000 ATM cells, at which a link is inhibited. The number is compared with average value of received ATM header errors in the last time. The length … | Integer32r/w Constraints: range: 0-100000 | .0.1.1.25 | ||||||||
| imaGroupErrorIntervalLinkDownThis indicates the duration of the measure interval in seconds for the ATM header error counter. That is used for calculating an average, which is then compared with the imaGroupErrorsLinkDown value. | Integer32r/w Constraints: range: 15-3600 | .0.1.1.26 | ||||||||
| imaGroupErrorsLinkUpThis indicates the threshold of the number of ATM header errors per 100000 ATM cells, at which a link is enabled again. The number is compared with average value of received ATM header errors in the last time. The len… | Integer32r/w Constraints: range: 0-100000 | .0.1.1.27 | ||||||||
| imaGroupErrorIntervalLinkUpThis indicates the duration of the measure interval in seconds for the ATM header error counter. That is used for calculating an average, which is then compared with the imaGroupErrorsLinkUp value. | Integer32r/w Constraints: range: 15-3600 | .0.1.1.28 | ||||||||
| imaGroupMinLinkDownTimeThis indicates the minimum waiting time in seconds before a link can be enabled again, after it has been inhibited. | Integer32r/w Constraints: range: 0-3600 | .0.1.1.29 |