automationConfigId
AUTOMATION-SYSTEM-MIB ·
.1.3.6.1.4.1.4329.6.3.2.1.3.5
Object
scalar OctetString
Signature of all configuration parameter values. The special value of all bytes 0x00 denotes the situation of a temporarily not available signature, what might happen during a configuration download while the signature is under construction. If the ConfigId cannot be built, no matter what reason (e.g. incompatibilities between parameter layout and build algorithm, out of resources, ...), get requestes must be responded with error 'noSuchInstance'.
Context
- MIB
- AUTOMATION-SYSTEM-MIB
- OID
.1.3.6.1.4.1.4329.6.3.2.1.3.5- Type
- scalar
- Access
- readonly
- Status
- current
- Parent
- automationSystemGeneric
- Groups
- 1
Net-SNMP examples
How SNMP and these commands workScalars have one instance, identified by the .0 suffix.
Read the scalar instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'AUTOMATION-SYSTEM-MIB' -M '/opt/observium/mibs/siemens:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'AUTOMATION-SYSTEM-MIB::automationConfigId.0'
More examples
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'AUTOMATION-SYSTEM-MIB' -M '/opt/observium/mibs/siemens:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'AUTOMATION-SYSTEM-MIB::automationConfigId'
Syntax
OctetString
Values & Constraints
Object Constraints
range: 64-64
Conformance
Member of