AUTOMATION-SYSTEM-MIB

        
Definition of generic management objects 
which describe a general I IA product.
    
Source file
AUTOMATION-SYSTEM-MIB
Last revised
Identity
automationSystemMIB
Base OID
1.3.6.1.4.1.4329.6.3.2
Imported Objects
AUTOMATION-SMI automationMgmt
AUTOMATION-TC AutomationFunctionStringTC AutomationLocationStringTC AutomationOrderNumberTC AutomationSerialNumberTC AutomationTriggerTC AutomationVersionNumberTC
SNMPv2-CONF MODULE-COMPLIANCE (no object page) NOTIFICATION-GROUP (no object page) OBJECT-GROUP (no object page)
SNMPv2-SMI Counter32 Integer32 IpAddress MODULE-IDENTITY (no object page) NOTIFICATION-TYPE (no object page) OBJECT-TYPE (no object page) Unsigned32
SNMPv2-TC DateAndTime DisplayString
Net-SNMP examples using the siemens MIB directory Show commands

These commands use the standard Observium installation path and load the selected MIB variant before the RFC and Net-SNMP directories.

Translate the module identity
/usr/bin/snmptranslate -Pud -Ir -On -m 'AUTOMATION-SYSTEM-MIB' -M '/opt/observium/mibs/siemens:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'AUTOMATION-SYSTEM-MIB::automationSystemMIB'
Walk the MIB subtree
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'AUTOMATION-SYSTEM-MIB' -M '/opt/observium/mibs/siemens:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'AUTOMATION-SYSTEM-MIB::automationSystemMIB'
How SNMP, Net-SNMP, MIB paths, and variants work
Objects (40)
.1.3.6.1.4.1.4329.6.3.2
.1.3.6.1.4.1.4329.6.3.2.1
.1.3.6.1.4.1.4329.6.3.2.1.1
Unsigned32
.1.3.6.1.4.1.4329.6.3.2.1.1.1
.1.3.6.1.4.1.4329.6.3.2.1.1.10
.1.3.6.1.4.1.4329.6.3.2.1.1.11
.1.3.6.1.4.1.4329.6.3.2.1.1.12
Integer32
.1.3.6.1.4.1.4329.6.3.2.1.1.13
Integer32
.1.3.6.1.4.1.4329.6.3.2.1.1.14
.1.3.6.1.4.1.4329.6.3.2.1.1.15
.1.3.6.1.4.1.4329.6.3.2.1.1.16
.1.3.6.1.4.1.4329.6.3.2.1.1.2
.1.3.6.1.4.1.4329.6.3.2.1.1.3
.1.3.6.1.4.1.4329.6.3.2.1.1.4
.1.3.6.1.4.1.4329.6.3.2.1.1.5
.1.3.6.1.4.1.4329.6.3.2.1.1.6
.1.3.6.1.4.1.4329.6.3.2.1.1.7
.1.3.6.1.4.1.4329.6.3.2.1.1.8
.1.3.6.1.4.1.4329.6.3.2.1.1.9
.1.3.6.1.4.1.4329.6.3.2.1.2
Enumeration
.1.3.6.1.4.1.4329.6.3.2.1.2.1
Enumeration
.1.3.6.1.4.1.4329.6.3.2.1.2.2
.1.3.6.1.4.1.4329.6.3.2.1.3
Enumeration
.1.3.6.1.4.1.4329.6.3.2.1.3.1
.1.3.6.1.4.1.4329.6.3.2.1.3.3
.1.3.6.1.4.1.4329.6.3.2.1.3.4
OctetString
.1.3.6.1.4.1.4329.6.3.2.1.3.5
.1.3.6.1.4.1.4329.6.3.2.1.3.6
.1.3.6.1.4.1.4329.6.3.2.1.3.7
.1.3.6.1.4.1.4329.6.3.2.1.4
automationSystemIpAddress deprecated r/w
.1.3.6.1.4.1.4329.6.3.2.1.4.1
.1.3.6.1.4.1.4329.6.3.2.1.4.2
automationSystemIpGateway deprecated r/w
.1.3.6.1.4.1.4329.6.3.2.1.4.3
automationSystemOutbandIp deprecated r/w
.1.3.6.1.4.1.4329.6.3.2.1.4.4
.1.3.6.1.4.1.4329.6.3.2.1.4.5
.1.3.6.1.4.1.4329.6.3.2.2
.1.3.6.1.4.1.4329.6.3.2.2.0
.1.3.6.1.4.1.4329.6.3.2.3
.1.3.6.1.4.1.4329.6.3.2.3.1
.1.3.6.1.4.1.4329.6.3.2.3.2
Dependencies (6) 5 direct · 1 transitive Show tree and compile order Hide dependency details

Each imported module is resolved in the importing module's source directory first, then through the normal default-variant rules.

Dependency tree
Dependency-first compile order
  1. SNMPv2-SMIrfc
  2. SIEMENS-SMIsiemens
  3. AUTOMATION-SMIsiemens
  4. SNMPv2-TCrfc
  5. AUTOMATION-TCsiemens
  6. SNMPv2-CONFrfc
  7. AUTOMATION-SYSTEM-MIBsiemensselected
Conformance Groups (14)
This group collects the named parameters
according to the referenced guideline.
.1.3.6.1.4.1.4329.6.3.2.3.1.1
This group collects the named parameters
according to the referenced guideline.
.1.3.6.1.4.1.4329.6.3.2.3.1.2
This group collects the named parameters
according to the referenced guideline.
The revision date is only available if
the system supports an absolute time,
therefore this group must be only
supported if the absolute time is
available.
.1.3.6.1.4.1.4329.6.3.2.3.1.3
Generic status information.
.1.3.6.1.4.1.4329.6.3.2.3.1.4
Allows restart via SNMP.
.1.3.6.1.4.1.4329.6.3.2.3.1.5
Allows reset of all counters.
.1.3.6.1.4.1.4329.6.3.2.3.1.6
IP configuration of the agent.
.1.3.6.1.4.1.4329.6.3.2.3.1.7
Configuration of the outband port.
.1.3.6.1.4.1.4329.6.3.2.3.1.8
Notifications about status changes.
.1.3.6.1.4.1.4329.6.3.2.3.1.9
Notifications about configuration changes.
.1.3.6.1.4.1.4329.6.3.2.3.1.10
This group collects the named parameters
according to the geographical coordinates.
.1.3.6.1.4.1.4329.6.3.2.3.1.11
This group collects the named parameters
according to the geographical coordinates
and the location dependent time shift.
.1.3.6.1.4.1.4329.6.3.2.3.1.12
This group collects the named parameters
for the suppport of a config signature.
.1.3.6.1.4.1.4329.6.3.2.3.1.13
This group collects the named parameters
for a firmware download.
.1.3.6.1.4.1.4329.6.3.2.3.1.14
Compliance Statements (3)

OID .1.3.6.1.4.1.4329.6.3.2.3.2.1
Minimum implementation requirements for all
Industry Automation Division systems
with SNMP support.
Required groups
mandatory automationIM0Group
optional automationIM1Group Required if the system provides I&M 1.
optional automationIM2Group Required if the system provides I&M 2.
optional automationStatusGroup Required if the system provides a
collective status information.
optional automationResetCounterGroup Required for systems which provide a
reset of all their counters.

OID .1.3.6.1.4.1.4329.6.3.2.3.2.2
Extended requirements for
Industry Automation Division systems.
Required groups
mandatory automationIM0Group
optional automationIM1Group Required if the system provides I&M 1.
optional automationIM2Group Required if the system provides I&M 2.
optional automationIpGroup Required if the system allows configuring of
the IP parameters via SNMP and no other MIBs
are implemented which support management of
this parameters.
optional automationOutbandGroup Required if the system provides an outband
port and management of this port is allowed
via SNMP and no other MIBs are implemented
which support management of the outband
port.
optional automationRemoteRestartGroup Required if restart of the system via
SNMP allowed.
optional automationStatusGroup Required if the system provides a
collective status information.
optional automationResetCounterGroup Required for systems which provide a
reset of all their counters.
optional automationConfigurationEvents Required for systems which provide
notifications.
optional automationStatusEvents Required for systems which provide
notifications.
optional automationGeoLocation Required for systems which provide
geographical coordinates.
optional automationGeoLocationTimeShift Required for systems which provide
geographical coordinates and time shift.

OID .1.3.6.1.4.1.4329.6.3.2.3.2.3
Extended requirements for
Industry Automation Division systems.
Required groups
mandatory automationIM0Group
optional automationIM1Group Required if the system provides I&M 1.
optional automationIM2Group Required if the system provides I&M 2.
optional automationRemoteRestartGroup Required if restart of the system via
SNMP allowed.
optional automationStatusGroup Required if the system provides a
collective status information.
optional automationResetCounterGroup Required for systems which provide a
reset of all their counters.
optional automationConfigurationEvents Required for systems which provide
notifications.
optional automationStatusEvents Required for systems which provide
notifications.
optional automationGeoLocation Required for systems which provide
geographical coordinates.
optional automationGeoLocationTimeShift Required for systems which provide
geographical coordinates and time shift.
optional automationConfigIdGroup Required for systems which provide
configuration signatures.
optional automationSwDownloadGroup Required for systems which support
firmware download.
Notifications / Traps (2)
NameOIDDescription
.1.3.6.1.4.1.4329.6.3.2.2.0.1
The system triggers this event in case the
value of automationOperState changed.
.1.3.6.1.4.1.4329.6.3.2.2.0.2
The system triggers this event in case the
configuration changed (e. g. the hardware
configuration, a firmware update or IP
parameter).