fanAndPsMainPSUStatus
AT-SYSINFO-MIB ·
.1.3.6.1.4.1.207.8.4.4.3.1.2
Object
scalar
Enumeration
The status of the main Power Supply. on means that the power supply is present and fully operational. off means that the power supply is totally off (and obviously only applies to systems with a redundant power supply). faulty means that the main power supply is delivering power but that a component of the power supply is faulty. This applies to systems like SwitchBlade which have 3 power supplies but do not provide individual power supply monitoring. Also, in the case of SwitchBlade, power supply status includes the status of the fans in the power supply.
Context
- MIB
- AT-SYSINFO-MIB
- OID
.1.3.6.1.4.1.207.8.4.4.3.1.2- Type
- scalar
- Access
- readonly
- Status
- current
- Parent
- fanAndPs
- Siblings
- 12
Syntax
Enumeration
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| fanAndPsTrap | node | - | .1.3.6.1.4.1.207.8.4.4.3.1.0 |
| fanAndPsRpsConnectionStatus The status of the Redundant Power Supply (RPS) connection,
ie, whether an RPS is actually connected or not, regardless
of whether the RPS is on or not. notSupported means that an
… | scalar | Enumeration | .1.3.6.1.4.1.207.8.4.4.3.1.1 |
| fanAndPsMainMonitoringStatus The current status of main power supply monitoring. The
monitoring of the main power supply and its fan is always
enabled by those systems that support it. Systems which do
not su… | scalar | Enumeration | .1.3.6.1.4.1.207.8.4.4.3.1.10 |
| fanAndPsPsuStatusTable The table of AT8948 fanAndPsPsuStatusTable. Each entry in the table
represents the status of one of the power supplies in AT8948 system.
Each power supply has its own board ID. | table | - | .1.3.6.1.4.1.207.8.4.4.3.1.11 |
| fanAndPsAccelFanStatus The status of the accelerator card fans. Non-supported means this
device does not support monitoring of the accelerator card fans. | scalar | Enumeration | .1.3.6.1.4.1.207.8.4.4.3.1.12 |
| fanAndPsRedundantPSUStatus The status of the redundant Power Supply. notSupported means
this device does not support redundant power supplies, on
means that the redundant power supply is connected and able
… | scalar | Enumeration | .1.3.6.1.4.1.207.8.4.4.3.1.3 |
| fanAndPsRpsMonitoringStatus The current status of redundant power supply monitoring. The
monitoring of the redundant power supply and its fan must be
enabled by command or by setting this variable to on. The… | scalar | Enumeration | .1.3.6.1.4.1.207.8.4.4.3.1.4 |
| fanAndPsMainFanStatus The status of the main Power Supply fan. notSupported means that this
device does not support monitoring on the main power supply fan, or that
there is no main power supply fan. T… | scalar | Enumeration | .1.3.6.1.4.1.207.8.4.4.3.1.5 |
| fanAndPsRedundantFanStatus The status of the redundant Power Supply Fan. notSupported means
this device does not support redundant power supplies, ok
means that the redundant power supply fan is running, no… | scalar | Enumeration | .1.3.6.1.4.1.207.8.4.4.3.1.6 |
| fanAndPsTemperatureStatus The status of temperature in this device. ok means that the
device is not capable of monitoring temperature or that the
temperature is OK, notOk means that the temperature is bein… | scalar | Enumeration | .1.3.6.1.4.1.207.8.4.4.3.1.7 |
| fanAndPsFanTrayPresent The status of the presence of the fan tray in this system. Systems
which do not support a fan tray return the value notSupported. Upon
removal of the fan tray there is a short per… | scalar | Enumeration | .1.3.6.1.4.1.207.8.4.4.3.1.8 |
| fanAndPsFanTrayStatus The status of the fan tray in this system. Systems which do not support
a fan tray return the value notSupported. The value ok is returned if all fans
in the fan tray are running … | scalar | Enumeration | .1.3.6.1.4.1.207.8.4.4.3.1.9 |