asamSystemArpPollingInterval

ASAM-SYSTEM-MIB · .1.3.6.1.4.1.637.61.1.9.59

Object

scalar r/w Integer32
The value of the object asamSystemArpPollingInterval specifies ARP polling interval. The range of the value is from 120s to 1096s.The default polling interval is 120s.
ALCATEL NOTE:
          ACCESS:      RW            USAGE:       MAND
          PERSIST:     YES           INSRVMOD:    NO
          RANGE:       120..1096     DEFVALUE:    120
          UNITS:       NA            SPARSE:      NA
          DESCR:       NA

Context

MIB
ASAM-SYSTEM-MIB
OID
.1.3.6.1.4.1.637.61.1.9.59
Type
scalar
Access
readwrite
Status
current
Parent
asamSystemMIB

Scalars have one instance, identified by the .0 suffix.

Read the scalar instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'ASAM-SYSTEM-MIB' -M '/opt/observium/mibs/alcatel:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ASAM-SYSTEM-MIB::asamSystemArpPollingInterval.0'
More examples
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'ASAM-SYSTEM-MIB' -M '/opt/observium/mibs/alcatel:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'ASAM-SYSTEM-MIB::asamSystemArpPollingInterval'