arrisMtaDevPwrSupplySecondsOnBattery2
ARRIS-MTA-DEVICE-MIB ·
.1.3.6.1.4.1.4115.1.3.3.1.3.5.12
Object
scalar
SNMPv2-SMIInteger32
Same as arrisMtaDevPwrSupplySecondsOnBattery but for 2nd battery.
Context
- MIB
- ARRIS-MTA-DEVICE-MIB
- OID
.1.3.6.1.4.1.4115.1.3.3.1.3.5.12- Type
- scalar
- Access
- readonly
- Status
- current
- Parent
- arrisMtaDevPwrSupplyStats
- Siblings
- 12
Syntax
SNMPv2-SMIInteger32
- Source
- SNMPv2-SMIInteger32
- Base type
Integer32
Values & Constraints
Type Constraints
range: -2147483648..2147483647
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| arrisMtaDevPwrSupplyBatRatedMinutes An estimate of the rated run-time on the battery based upon the unit's
typical idle power and the rated capacity of the battery when fully charged. | scalar | minutes SNMPv2-SMIInteger32 | .1.3.6.1.4.1.4115.1.3.3.1.3.5.10 |
| arrisMtaDevPwrSupplyBatAvailableMinutes An estimate of the available run-time on the battery based upon the unit's
typical idle power and the tested capacity of the battery when fully charged. | scalar | minutes SNMPv2-SMIInteger32 | .1.3.6.1.4.1.4115.1.3.3.1.3.5.11 |
| arrisMtaDevPwrSupplyBatRatedMinutes2 Same as arrisMtaDevPwrSupplyBatRatedMinutes but for 2nd battery. | scalar | minutes SNMPv2-SMIInteger32 | .1.3.6.1.4.1.4115.1.3.3.1.3.5.13 |
| arrisMtaDevPwrSupplyBatAvailableMinutes2 Same as arrisMtaDevPwrSupplyBatAvailableMinutes but for 2nd battery. | scalar | minutes SNMPv2-SMIInteger32 | .1.3.6.1.4.1.4115.1.3.3.1.3.5.14 |
| arrisMtaDevPwrSupplyTelemetryValues Power Supply Telemetry Values. Fields are delimited by semicolons. | scalar | SNMP-FRAMEWORK-MIBSnmpAdminString | .1.3.6.1.4.1.4115.1.3.3.1.3.5.15 |
| arrisMtaDevBatteryStatusTable The Power Supply Telemetry table ...There will be one row in this
table for each battery pack in the device | table | - | .1.3.6.1.4.1.4115.1.3.3.1.3.5.3 |
| arrisMtaDevPwrSupplyBatteryTestTime The present value of the Test Timer Scheduler expressed in days. If the value
read is 0xFF (255), the timer has been paused. | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.4115.1.3.3.1.3.5.4 |
| arrisMtaDevPwrSupplyRatedBatCapacity The rated capacity of the battery that is currently installed. The value is
expressed in units of energy (10 watt*minutes/count), rather than charge
(amp*hours). | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.4115.1.3.3.1.3.5.5 |
| arrisMtaDevPwrSupplyTestedBatCapacity The measured battery capacity expressed in 10 watt*minutes/count as determined
by the last battery test cycle. | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.4115.1.3.3.1.3.5.6 |
| arrisMtaDevPwrSupplyBatStateOfCharge The present battery state of charge expressed in 10 watt*minutes/count.
This value is approximate and is re-calibrated following a battery test cycle. | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.4115.1.3.3.1.3.5.7 |
| arrisMtaDevPwrSupplyReadBatteryPwr The present load power expressed in 50mW/count and is an eight-second
moving average. This is the power being removed or applied to the battery.
Power is being removed while AC is… | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.4115.1.3.3.1.3.5.8 |
| arrisMtaDevPwrSupplySecondsOnBattery The present value of time expired since AC Failed and running on the battery. | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.4115.1.3.3.1.3.5.9 |