arrisMtaDevPwrSupplyReplaceBatThresh

ARRIS-MTA-DEVICE-MIB · .1.3.6.1.4.1.4115.1.3.3.1.3.3.5

Object

scalar r/w SNMPv2-SMIInteger32
Sets the minimum acceptable battery charge needed to achieve the desired End of
Life holdup time based on typical Idle Power.  If the Tested Battery Capacity
minus the Charge Hysteresis loss (20%) is less than this value, the Replace
Battery alarm will be raised.  The variable is expressed in 10 watt*minutes/count.
The initial default value provides 1 hour of holdup time. (Only available on MODEL 5 and MODEL 6 modems. Not supported on TM508/512)