arrisMtaDevPwrSupplyReadBatteryPwr
ARRIS-MTA-DEVICE-MIB ·
.1.3.6.1.4.1.4115.1.3.3.1.3.5.8
Object
scalar
SNMPv2-SMIInteger32
The present load power expressed in 50mW/count and is an eight-second moving average. This is the power being removed or applied to the battery. Power is being removed while AC is not present or during the battery test. Power is being applied if battery is being charged.
Context
- MIB
- ARRIS-MTA-DEVICE-MIB
- OID
.1.3.6.1.4.1.4115.1.3.3.1.3.5.8- Type
- scalar
- Access
- readonly
- Status
- current
- Parent
- arrisMtaDevPwrSupplyStats
- Siblings
- 12
Syntax
SNMPv2-SMIInteger32
- Source
- SNMPv2-SMIInteger32
- Base type
Integer32
Values & Constraints
Type Constraints
range: -2147483648..2147483647
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| arrisMtaDevPwrSupplyBatRatedMinutes An estimate of the rated run-time on the battery based upon the unit's
typical idle power and the rated capacity of the battery when fully charged. | scalar | minutes SNMPv2-SMIInteger32 | .1.3.6.1.4.1.4115.1.3.3.1.3.5.10 |
| arrisMtaDevPwrSupplyBatAvailableMinutes An estimate of the available run-time on the battery based upon the unit's
typical idle power and the tested capacity of the battery when fully charged. | scalar | minutes SNMPv2-SMIInteger32 | .1.3.6.1.4.1.4115.1.3.3.1.3.5.11 |
| arrisMtaDevPwrSupplySecondsOnBattery2 Same as arrisMtaDevPwrSupplySecondsOnBattery but for 2nd battery. | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.4115.1.3.3.1.3.5.12 |
| arrisMtaDevPwrSupplyBatRatedMinutes2 Same as arrisMtaDevPwrSupplyBatRatedMinutes but for 2nd battery. | scalar | minutes SNMPv2-SMIInteger32 | .1.3.6.1.4.1.4115.1.3.3.1.3.5.13 |
| arrisMtaDevPwrSupplyBatAvailableMinutes2 Same as arrisMtaDevPwrSupplyBatAvailableMinutes but for 2nd battery. | scalar | minutes SNMPv2-SMIInteger32 | .1.3.6.1.4.1.4115.1.3.3.1.3.5.14 |
| arrisMtaDevPwrSupplyTelemetryValues Power Supply Telemetry Values. Fields are delimited by semicolons. | scalar | SNMP-FRAMEWORK-MIBSnmpAdminString | .1.3.6.1.4.1.4115.1.3.3.1.3.5.15 |
| arrisMtaDevBatteryStatusTable The Power Supply Telemetry table ...There will be one row in this
table for each battery pack in the device | table | - | .1.3.6.1.4.1.4115.1.3.3.1.3.5.3 |
| arrisMtaDevPwrSupplyBatteryTestTime The present value of the Test Timer Scheduler expressed in days. If the value
read is 0xFF (255), the timer has been paused. | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.4115.1.3.3.1.3.5.4 |
| arrisMtaDevPwrSupplyRatedBatCapacity The rated capacity of the battery that is currently installed. The value is
expressed in units of energy (10 watt*minutes/count), rather than charge
(amp*hours). | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.4115.1.3.3.1.3.5.5 |
| arrisMtaDevPwrSupplyTestedBatCapacity The measured battery capacity expressed in 10 watt*minutes/count as determined
by the last battery test cycle. | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.4115.1.3.3.1.3.5.6 |
| arrisMtaDevPwrSupplyBatStateOfCharge The present battery state of charge expressed in 10 watt*minutes/count.
This value is approximate and is re-calibrated following a battery test cycle. | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.4115.1.3.3.1.3.5.7 |
| arrisMtaDevPwrSupplySecondsOnBattery The present value of time expired since AC Failed and running on the battery. | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.4115.1.3.3.1.3.5.9 |