arrisMtaDevPwrSupplyFullChargeTime
ARRIS-MTA-DEVICE-MIB ·
.1.3.6.1.4.1.4115.1.3.3.1.3.4.2
Object
Causes the battery to be charged to 100% of its rated voltage and be maintained at that level according the number of days set by the data. After the time has elapsed, the battery charge level will be returned to the value specified by arrisMtaDevPwrSupplyChargeState. Range of reported values: 0-16 days. Values that can be written range from 1-16 days. If 1 is written the full charge level will be maintained for 1 day. After that the full charge state will be aborted and the battery charge will return to the set charge level or a test will resume if one is pending. (This MIB is only effective on TM5xx and TM6xx HW models)
Context
- MIB
- ARRIS-MTA-DEVICE-MIB
- OID
.1.3.6.1.4.1.4115.1.3.3.1.3.4.2- Type
- scalar
- Access
- readwrite
- Status
- current
- Parent
- arrisMtaDevPwrSupplyTimers
- Siblings
- 1
Syntax
SNMPv2-SMIInteger32
- Source
- SNMPv2-SMIInteger32
- Base type
Integer32
Values & Constraints
Type Constraints
range: -2147483648..2147483647
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| arrisMtaDevPwrSupplyDataShutdownTime Indicates the timeout period, in seconds, that the device will terminate
data services. The timer will start upon loss of AC power and operation
of battery backup begins. Afte… | scalar | seconds SNMPv2-SMIInteger32 | .1.3.6.1.4.1.4115.1.3.3.1.3.4.1 |