arrisMtaDevPwrSupplyFullChargeTime

ARRIS-MTA-DEVICE-MIB · .1.3.6.1.4.1.4115.1.3.3.1.3.4.2

Object

scalar r/w Integer32
Causes the battery to be charged to 100% of its rated voltage and be maintained
at that level according the number of days set by the data.  After the time has
elapsed, the battery charge level will be returned to the value specified by
arrisMtaDevPwrSupplyChargeState.  Range of reported values: 0-16 days.
Values that can be written range from 1-16 days.  If 1 is written the full charge
level will be maintained for 1 day.  After that the full charge state will be
aborted and the battery charge will return to the set charge level or a test
will resume if one is pending.  (This MIB is only effective on TM5xx and TM6xx HW models)

Context

MIB
ARRIS-MTA-DEVICE-MIB
OID
.1.3.6.1.4.1.4115.1.3.3.1.3.4.2
Type
scalar
Access
readwrite
Status
current
Parent
arrisMtaDevPwrSupplyTimers

Syntax

Integer32

Values & Constraints

No enumerated values or constraints recorded.