arrisMtaDevPwrSupplyConfigRunTime

ARRIS-MTA-DEVICE-MIB · .1.3.6.1.4.1.4115.1.3.3.1.3.3.9

Object

scalar r/w minutes SNMPv2-SMIInteger32
An estimate of the available run-time on the battery based upon the unit's
typical idle power and the programmed battery charge setting.  The available
battery back up time may be adjusted using this value.  By programming the
run-time to a lower value, the total service life of the battery is extended.
Increasing the run-time in turn decreases the total service life of the battery.
Setting this value greater than arrisMtaDevPwrSupplyBatAvailableMinutes will not
provide a run-time greater than arrisMtaDevPwrSupplyBatAvailableMinutes.  This
value can only be set to multiples of 5 minutes.

Context

MIB
ARRIS-MTA-DEVICE-MIB
OID
.1.3.6.1.4.1.4115.1.3.3.1.3.3.9
Type
scalar
Access
readwrite
Status
current
Units
minutes
Parent
arrisMtaDevPwrSupplyControl
Siblings
17

Syntax

minutes SNMPv2-SMIInteger32
Source
SNMPv2-SMIInteger32
Base type
Integer32

Values & Constraints

Type Constraints
range: -2147483648..2147483647

Related Objects