arrisMtaDevPwrSupplyBatteryTest
ARRIS-MTA-DEVICE-MIB ·
.1.3.6.1.4.1.4115.1.3.3.1.3.3.8
Object
scalar
r/w
Enumeration
This MIB cannot be set on TM402 devices.
This feature controls the scheduling of the battery test.
TestScheduled: When written, causes the battery test scheduler to resume at its
current value. When read, means that the battery test will run when the scheduled
time expires.
DisableAutoTesting: When written, freezes the battery test scheduler at its
current value. When read, means that the battery test will never run - with one
exception. If a battery is removed and replaced, the test will run immediately.
Once the test completes, the pause status will still be in effect. Therefore,
the battery test will not run a second time.
TestInProgress: When written, causes the battery test cycle to start immediately
and the test scheduler to be reset to its default value of 180 days. This command
is ignored if there is a test in progress. When read, means test in progress.
TestPending: If a battery test is in progress and either: AC power is lost; or a
full charge is requested - the battery test is paused and the status is reported
as pending. This is a read-only value.
Context
- MIB
- ARRIS-MTA-DEVICE-MIB
- OID
.1.3.6.1.4.1.4115.1.3.3.1.3.3.8- Type
- scalar
- Access
- readwrite
- Status
- current
- Parent
- arrisMtaDevPwrSupplyControl
- Siblings
- 17
Syntax
Enumeration
Values & Constraints
Enumerated Values
0 | testScheduled |
1 | disableAutoTesting |
2 | testInProgress |
3 | testPending |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| arrisMtaDevPwrSupplyEnableDataShutdown | scalar | Enumeration | .1.3.6.1.4.1.4115.1.3.3.1.3.3.1 |
| arrisMtaDevPwrSupplyConfigReplaceBatTime Determines the replace battery threshold in terms of run-time minutes. If a battery's
capacity has degraded to a point where it can no longer provide more than x minutes of
run-t… | scalar | minutes SNMPv2-SMIInteger32 | .1.3.6.1.4.1.4115.1.3.3.1.3.3.10 |
| arrisMtaDevPwrSupplyConfigReplaceBatTime2 Same as arrisMtaDevPwrSupplyConfigReplaceBatTime but for 2nd battery. | scalar | minutes SNMPv2-SMIInteger32 | .1.3.6.1.4.1.4115.1.3.3.1.3.3.11 |
| arrisMtaDevPwrSupplyOverTempAlarmControl Determines whether an Over Temperature Alarm is issued when the temperature
specified in arrisMtaDevPwrSupplyOverTempAlarmThreshold is reached. Also
determines whether the batter… | scalar | Enumeration | .1.3.6.1.4.1.4115.1.3.3.1.3.3.12 |
| arrisMtaDevPwrSupplyOverTempAlarmThreshold Determines temperature threshold for Over Temperature Alarm. Minimum
temperature is 50C. Maximum is 70C. | scalar | degrees-C SNMPv2-SMIInteger32 | .1.3.6.1.4.1.4115.1.3.3.1.3.3.13 |
| arrisMtaDevPwrSupplyTemperature The current temperature in degrees C. This is only available
when arrisMtaDevPwrSupplyOverTempAlarmControl is enabled. | scalar | SNMP-FRAMEWORK-MIBSnmpAdminString | .1.3.6.1.4.1.4115.1.3.3.1.3.3.14 |
| arrisMtaDevPwrSupplyHiTempBatteryShutdownControl Determines whether the battery will be turned off when the temperature
reaches 75C and above. | scalar | Enumeration | .1.3.6.1.4.1.4115.1.3.3.1.3.3.15 |
| arrisMtaDevPwrSupplyHighestTemperature The highest recorded battery charger temperature in degrees C. This is only available
when arrisMtaDevPwrSupplyOverTempAlarmControl is enabled. | scalar | SNMP-FRAMEWORK-MIBSnmpAdminString | .1.3.6.1.4.1.4115.1.3.3.1.3.3.16 |
| arrisMtaDevPwrSupplyHighestTemperatureTime Displays the time and date when the highest temperature was recorded. | scalar | SNMP-FRAMEWORK-MIBSnmpAdminString | .1.3.6.1.4.1.4115.1.3.3.1.3.3.17 |
| arrisMtaDevPwrSupplyHighestTemperatureClear Setting this MIB Clears arrisMtaDevPwrSupplyHighestTemperature and
arrisMtaDevPwrSupplyHighestTemperatureTime. These MIBs will be assigned
new values in a maximum of 4 seconds w… | scalar | Enumeration | .1.3.6.1.4.1.4115.1.3.3.1.3.3.18 |
| arrisMtaDevPwrSupplyControlChargerReset This MIB object will reset the battery charger when set to true(1).
Warning: Resetting the battery charger in an AC Fail condition will immediately
shutdown the unit. This MI… | scalar | SNMPv2-TCTruthValue | .1.3.6.1.4.1.4115.1.3.3.1.3.3.19 |
| arrisMtaDevPwrSupplyEnableWifiShutdown This MIB allows WTMx52 modems to shut down its wireless signal for power saving when modem switches to battery power.
If set this MIB to true, when AC fail and MTA is on Battery … | scalar | Enumeration | .1.3.6.1.4.1.4115.1.3.3.1.3.3.2 |
| arrisMtaDevPwrSupplyLowBatteryThresh Sets the low battery threshold, which is used to detect a low battery condition.
The variable is expressed in 10 watt*minutes/count. The initial default value
is equivalent to 1 … | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.4115.1.3.3.1.3.3.3 |
| arrisMtaDevPwrSupplyTypicalIdlePwr The typical Idle power expressed in 50 mw/count. A typical value is
loaded upon power up. It is used in conjunction with the Tested Battery Capacity,
Low Battery Threshold and th… | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.4115.1.3.3.1.3.3.4 |
| arrisMtaDevPwrSupplyReplaceBatThresh Sets the minimum acceptable battery charge needed to achieve the desired End of
Life holdup time based on typical Idle Power. If the Tested Battery Capacity
minus the Charge Hyst… | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.4115.1.3.3.1.3.3.5 |
| arrisMtaDevPwrSupplyChargeState Causes the battery to be charged to the level that is specified by the data.
The value of charge is expressed in 10 watt*minutes/count. In order for the
battery to be charged to … | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.4115.1.3.3.1.3.3.6 |
| arrisMtaDevPwrSupplyConfigRunTime An estimate of the available run-time on the battery based upon the unit's
typical idle power and the programmed battery charge setting. The available
battery back up time may be… | scalar | minutes SNMPv2-SMIInteger32 | .1.3.6.1.4.1.4115.1.3.3.1.3.3.9 |