arrisMtaDevProvisionedCodecArray
ARRIS-MTA-DEVICE-MIB ·
.1.3.6.1.4.1.4115.1.3.3.1.2.3.51
Object
This is the list of codecs offered in the SDP as well as codecs returned in capabilities
for an AUEP response.
This MIB is only used with NCS signaling.
These are entered as a string separated by semi-colon ';' or comma ',' for example
'PCMU;PCMA;G726-32;telephone-event'.
This object should only be changed by the configuration file.
The default string will be NULL. A NULL string will result in consistent operation to previous
FW releases where all supported codecs are listed.
Context
- MIB
- ARRIS-MTA-DEVICE-MIB
- OID
.1.3.6.1.4.1.4115.1.3.3.1.2.3.51- Type
- scalar
- Access
- readwrite
- Status
- current
- Parent
- arrisMtaDevOperationalSetup
Net-SNMP examples
How SNMP and these commands workScalars have one instance, identified by the .0 suffix.
Read the scalar instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'ARRIS-MTA-DEVICE-MIB' -M '/opt/observium/mibs/arris:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ARRIS-MTA-DEVICE-MIB::arrisMtaDevProvisionedCodecArray.0'
More examples
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'ARRIS-MTA-DEVICE-MIB' -M '/opt/observium/mibs/arris:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'ARRIS-MTA-DEVICE-MIB::arrisMtaDevProvisionedCodecArray'
Syntax
- Source
- SNMPv2-TCDisplayString
- Base type
OctetString- Display format
255a
Type Description
Represents textual information taken from the NVT ASCII
character set, as defined in pages 4, 10-11 of RFC 854.
To summarize RFC 854, the NVT ASCII repertoire specifies:
- the use of character codes 0-127 (decimal)
- the graphics characters (32-126) are interpreted as
US ASCII
- NUL, LF, CR, BEL, BS, HT, VT and FF have the special
meanings specified in RFC 854
- the other 25 codes have no standard interpretation
- the sequence 'CR LF' means newline
- the sequence 'CR NUL' means carriage-return
- an 'LF' not preceded by a 'CR' means moving to the
same column on the next line.
- the sequence 'CR x' for any x other than LF or NUL is
illegal. (Note that this also means that a string may
end with either 'CR LF' or 'CR NUL', but not with CR.)
Any object defined using this syntax may not exceed 255
characters in length.
Values & Constraints
Type Constraints
range: 0..255