arrisMtaDevLoopVoltagePolicy
ARRIS-MTA-DEVICE-MIB ·
.1.3.6.1.4.1.4115.1.3.3.1.2.3.11.2
Object
scalar
r/w
Enumeration
1. Maintain loop idle voltage at all times. 2. Apply loop idle voltage at all times except when no RF QAM carrier is detected. The intent of this policy option is to maintain idle voltage for all normal operation but to remove it if RF conditions appear to match a malicious cable cut (such may happen if a burglar is trying to disable the alarm system). 3. Apply loop idle voltage only when the MTA device is In-service (MTA IP address is received and valid config file has been received) and during manually initiated resets (either reset button or SNMP). If this policy criterion is selected, then the EMTA MUST maintain loop idle voltage if a reset command is received (via SNMP or reset button or as part of a management initiated software upgrade). Once the MTA has come back in- service, any subsequent MTA out-of-service condition MUST result in removal of loop idle voltage (except for another manually initiated reset). As a failsafe, if the MTA has not come in-service within a provisionable time, then loop idle voltage MUST be removed. 4. Apply loop idle voltage whenever the MTA device is in-service. 5. This MIB is only writable via configuration file.
Context
- MIB
- ARRIS-MTA-DEVICE-MIB
- OID
.1.3.6.1.4.1.4115.1.3.3.1.2.3.11.2- Type
- scalar
- Access
- readwrite
- Status
- current
- Parent
- arrisMtaDevLoopVoltageMgmt
- Siblings
- 3
Syntax
Enumeration
Values & Constraints
Enumerated Values
1 | always-voltage-present |
2 | rf-carrier-voltage-present |
3 | in-service-voltage-present |
4 | default-operation |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| arrisMtaDevLoopVoltageKey When correct key is entered, Loop Voltage Mgmt. policy can be set.
This MIB is only writable via configuration file. | scalar | SNMP-FRAMEWORK-MIBSnmpAdminString | .1.3.6.1.4.1.4115.1.3.3.1.2.3.11.1 |
| arrisMtaDevLoopVoltageResetTimeout Specifies the time after which to remove loop voltage if the MTA has not come
in-service. Acceptable range is 8-1800 seconds. Stored value must be divisible
by 8 (any remainder w… | scalar | seconds SNMPv2-SMIInteger32 | .1.3.6.1.4.1.4115.1.3.3.1.2.3.11.3 |
| arrisMtaDevLoopVoltageMaintTimeout Specifies the time that loop voltage will be supplied regardless of RF condition.
See arrisMtaDevLoopVoltagePolicy for more detailed information.
This MIB is only writable via co… | scalar | minutes SNMPv2-SMIInteger32 | .1.3.6.1.4.1.4115.1.3.3.1.2.3.11.4 |