arrisCmDoc30SetupTODSyncTimeout
ARRIS-CM-DOC30-DEVICE-MIB ·
.1.3.6.1.4.1.4115.1.3.4.1.3.22
Object
This value determines the interval between the TOD sync operations. Range is 0-4320 hours, where 0 disables the sync completely. This value sets the interval starting from the setting of the new value. Hence a setting of 10 causes the TOD server to sync every 10 hours from the time the value was set Feature is disable by default
Context
- MIB
- ARRIS-CM-DOC30-DEVICE-MIB
- OID
.1.3.6.1.4.1.4115.1.3.4.1.3.22- Type
- scalar
- Access
- readwrite
- Status
- current
- Parent
- arrisCmDoc30Setup
Net-SNMP examples
How SNMP and these commands workScalars have one instance, identified by the .0 suffix.
Read the scalar instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'ARRIS-CM-DOC30-DEVICE-MIB' -M '/opt/observium/mibs/arris:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ARRIS-CM-DOC30-DEVICE-MIB::arrisCmDoc30SetupTODSyncTimeout.0'
More examples
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'ARRIS-CM-DOC30-DEVICE-MIB' -M '/opt/observium/mibs/arris:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'ARRIS-CM-DOC30-DEVICE-MIB::arrisCmDoc30SetupTODSyncTimeout'
Syntax
- Source
- SNMPv2-SMIGauge32
- Base type
Unsigned32
Values & Constraints
Type Constraints