arrisCmDoc30SetupExtendedUpstreamTransmitPowerValue
ARRIS-CM-DOC30-DEVICE-MIB ·
.1.3.6.1.4.1.4115.1.3.4.1.3.32
Object
scalar
r/w
Integer32
When enabled, extended upstream transmit power capabilities will be reported in REG-REQ-MP
message. Setting to 0 disables this functionality. Setting to nonzero controls what Pmax
the modem advertises in 0.25dB steps. The default value is hardware-specific.
It is not recommended to change from default values. Exceeding the capabilities of the upstream
amplifier may introduce distortions and spurs which may decrease SNR of this upstream channel and
adjacent upstream channels. Please refer to the Firmware Guide and take care when setting this value.
Context
- MIB
- ARRIS-CM-DOC30-DEVICE-MIB
- OID
.1.3.6.1.4.1.4115.1.3.4.1.3.32- Type
- scalar
- Access
- readwrite
- Status
- current
- Parent
- arrisCmDoc30Setup
Syntax
Integer32
Values & Constraints
Object Constraints
range: 0-0
range: 205-244