issAclTrcFlag
ARICENT-ISS-ACL-MIB ·
.1.3.6.1.4.1.29601.2.21.8.1
Object
scalar
r/w
Unsigned32
This object is used to enable trace statements in Acl module.
A four byte integer is used for enabling the trace level.
Each bit in the four byte integer represents a particular
trace level.
The mapping between the bit positions & the trace level is
as follows:
0 - Init and Shutdown traces
1 - Management traces
2 - Data Path traces
3 - Control Plane traces
5 - Traces related to all resources except buffers
6 - Buffer allocation/release traces
7 - All Failure traces
None of the bit is set the Disable the Trace,value(0).
The remaining bits are unused. Combination of levels are
also allowed.
For example if the bits 0 and 1 are set, then the trace
statement related to Init-Shutdown and management
will be printed.
The user has to enter the corresponding integer value for the
bits set. For example if bits 0 and 1 are to be set ,then user
has to give the value 3.
Context
- MIB
- ARICENT-ISS-ACL-MIB
- OID
.1.3.6.1.4.1.29601.2.21.8.1- Type
- scalar
- Access
- readwrite
- Status
- current
- Parent
- issAclTrc
Syntax
Unsigned32
Values & Constraints
Object Constraints
range: 0-255