aluSapEthLoopbackDuration
ALU-SERVICE-MIB ·
.1.3.6.1.4.1.6527.6.1.2.2.6.14.1.2
Object
column
r/w
Unsigned32
aluSapEthLoopbackDuration is used to specify the time duration, in seconds, to set the sap
into a testhead loopback mode. Setting aluSapEthLoopbackDuration to a non-zero value must be accompanied by
setting aluSapEthLoopback to 'true' for the same sap. When this timer expires,
it will be reset to the default value 0 by the system.
Set aluSapEthLoopbackDuration to 0 to keep the loopback mode until modified by the operator.
Context
- MIB
- ALU-SERVICE-MIB
- OID
.1.3.6.1.4.1.6527.6.1.2.2.6.14.1.2- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- aluSapEthLoopbackEntry
Syntax
Unsigned32
Values & Constraints
Object Constraints
range: 0-0