aluRS232InvertClock

ALU-PORT-MIB · .1.3.6.1.4.1.6527.6.1.2.2.2.4.5.1.36

Object

column r/w TIMETRA-TC-MIBTmnxEnabledDisabled
The value of aluRS232InvertClock specifies whether to invert the
clock edge that the interface samples for received data (if local
gender is DCE) or transmitted data (if local gender is DTE).
              
Inverting the clock may correct issues such as those related to phase
shift. For example, data changes state near the interface's sampling
clock edge. Contributors to phase shift variance include, but are not
limited to: cable length and interface rate.
              
'enabled' not supported on SAR-H and SAR-Hc systems.
'enabled' not supported on sdiv1 and sdiv2.
'enabled' not allowed while aluRS232DeviceMode is asynchronous.

Context

MIB
ALU-PORT-MIB
OID
.1.3.6.1.4.1.6527.6.1.2.2.2.4.5.1.36
Type
column
Access
readwrite
Status
current
Parent
aluRS232Entry

Syntax

TIMETRA-TC-MIBTmnxEnabledDisabled

Values & Constraints

No enumerated values or constraints recorded.