aluRS232ControlLeadRdlRi
ALU-PORT-MIB ·
.1.3.6.1.4.1.6527.6.1.2.2.2.4.5.1.18
Object
column
r/w
AluRS232ControlLead
aluRS232ControlLeadRdlRi is used to configure the RDL/RI input lead
to an ASSUMED value.
For RS-232:
if local gender is DCE, lead indicates Remote Digital Loopback
if local gender is DTE, lead indicates Ring Indicator
For V.35 and X.21:
lead is undefined
For RS-530, RdlRi represents LlTm:
if local gender is DCE, lead indicates Local Loopback
if local gender is DTE, lead indicates Test Mode
Valid values are 'high' and 'low'.
This object is not supported on the SAR-H and SAR-Hc systems.
Context
- MIB
- ALU-PORT-MIB
- OID
.1.3.6.1.4.1.6527.6.1.2.2.2.4.5.1.18- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- aluRS232Entry
Syntax
AluRS232ControlLead
Values & Constraints
No enumerated values or constraints recorded.