aluMwRadioRemoteRxMainPower
ALU-MICROWAVE-MIB ·
.1.3.6.1.4.1.6527.6.1.2.2.7.1.3.1.4
Object
column Integer32
This object represents the remote received power level. In case of space diversity configuration with combiner function in base band it is used to represent the power at the input of the remote main receiver. It is a negative integer with associated measure unit expressed in decade of dBm.
Context
- MIB
- ALU-MICROWAVE-MIB
- OID
.1.3.6.1.4.1.6527.6.1.2.2.7.1.3.1.4- Type
- column
- Access
- readonly
- Status
- current
- Parent
- aluMwRadioPowerMeasuresEntry
- Groups
- 1
Net-SNMP examples
How SNMP and these commands workWalk the column to discover its indexed instances, or supply every index to read one instance.
Walk the column
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'ALU-MICROWAVE-MIB' -M '/opt/observium/mibs/nokia:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ALU-MICROWAVE-MIB::aluMwRadioRemoteRxMainPower'
More examples
Read one indexed instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'ALU-MICROWAVE-MIB' -M '/opt/observium/mibs/nokia:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ALU-MICROWAVE-MIB::aluMwRadioRemoteRxMainPower.<tmnxChassisIndex>.<aluMwRadioPortID>'
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'ALU-MICROWAVE-MIB' -M '/opt/observium/mibs/nokia:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'ALU-MICROWAVE-MIB::aluMwRadioRemoteRxMainPower'
Syntax
Integer32
Values & Constraints
Object Constraints
range: -1000-0
Conformance
Member of