adTa5kEquipmentRedundancySwitchToProtect
ADTRAN-TA5K-REDUNDANCY-MIB ·
.1.3.6.1.4.1.664.5.67.1.1.3.0.13
Object
notification
This alarm indicates that the 'working' module has failed and the 'protect' module is now active. This alarm is only generated when revertive mode is enabled. The 'working' module is always the left-most module (odd slot). The 'protect' module is always the right-most module (even slot).
Context
- MIB
- ADTRAN-TA5K-REDUNDANCY-MIB
- OID
.1.3.6.1.4.1.664.5.67.1.1.3.0.13- Type
- notification
- Status
- current
- Parent
- adTa5kRedundancyAlarms
Net-SNMP examples
How SNMP and these commands workNotifications are emitted by an agent; they cannot be read with snmpget or walked.
Inspect the notification definition
/usr/bin/snmptranslate -Pud -Ir -Td -m 'ADTRAN-TA5K-REDUNDANCY-MIB' -M '/opt/observium/mibs/adtran:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'ADTRAN-TA5K-REDUNDANCY-MIB::adTa5kEquipmentRedundancySwitchToProtect'
More examples
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'ADTRAN-TA5K-REDUNDANCY-MIB' -M '/opt/observium/mibs/adtran:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'ADTRAN-TA5K-REDUNDANCY-MIB::adTa5kEquipmentRedundancySwitchToProtect'
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.