systemParameter
ACE202-MIB ·
.1.3.6.1.4.1.164.6.2.18
Object
scalar
r/w
Integer32
This parameter can be used for different purposes:
- TELNET session time-out in seconds.
- Ace20: when trying to create row in a table that already
has row with the same values, if set of values has to be unique
in table, this attribute is set to the index of the existing row.
- Optimux-T3: when CH interfaces are RJ-45, user can select via this
object, the interface type for each Group of channels: T1 or E1:
The selection will be a sum of the following Bits.
'0' = T1
'1' = E1
Bit Group Value for each Bit having '1'
1 1 (CH-1..CH-8) 1
2 2 (CH-9..CH-12) 2
3 3 (CH-13..CH-20) 4
4 4 (CH-21..CH-28) 8
Examples:
15 = all Groups are selected to be E1
6 = Group 2 and Group 3 are selected to be E1
(Group 1 and Group 4 are T1).
- FCD-A, FCD-M: user can select via this object the configuration
used for Get values of MSDSL parameters that don't have
configuration index.
1 =active configuration
255=temporary configuration.
Set of this object should be done before Getting the MSDSL
RW parameters.
- Ace2002: This parameter indicates the number of intervals that
were successfully uploaded upon statistics collection session.
- FCD-IP, WR, FCD-IPD, LA-240:
This parameter indicates whether Telnet Access is enabled/disabled:
Values:
2 - Telnet Access is Disabled.
3 - Telnet Access is Enabled.
Context
- MIB
- ACE202-MIB
- OID
.1.3.6.1.4.1.164.6.2.18- Type
- scalar
- Access
- readwrite
- Status
- current
- Parent
- agnt
Syntax
Integer32
Values & Constraints
No enumerated values or constraints recorded.