prtTestCmdAndStatus
ACE2002-MIB ·
.1.3.6.1.4.1.164.6.2.15.4.1.1.2
Object
column
r/w
Integer32
Setting this object to a value as detailed further on
(except 0) will initiate a test on the specific port.
The test/s requested will be set according to the respective
bit. The value of this object will be a sum of (2**n), where n is
the Bit:
TEST BIT VALUE
----------- --- ------
reserved 0 1
PayloadLoop=RLB 1 (=Remote Loopback) 2
LineLoop=DIG 2 (=Digital) 4
OtherLoop 3 8
InwardLoop=LLB 4 (=Local Loopback) 16
BERT 5 32
LC 6 64
ToneInjection 7 128
Inband 8 256
e.g : If the requested value is 20 -> 010100 ->
Bits 2 & 4 are set -> the requested tests are :
LineLoopback=DIG
InwardLoopback=LLB
Not all tests combinations are valid.
For valid test combination, see each product's specification.
For LRS52, only single test is allowed simultaneously
The terminology and order of the first tests (except BERT)
is according to the one used for Test Status of DS1 and DS3 standards.
The notations : RLB, LLB, DIG are the most used in RAD's products, but they
can be different. For exact definition see product's spec.
Setting this object to stop (value=0 ; all bits are 0),
will stop all the user requested tests running on the
selected port.
When no test is running on the port, the Get value (test status)
will be 0.
PayloadLoop=RLB
The received signal at this interface is looped
through the device. Typically the received signal
is looped back for retransmission after it has
passed through the device's framing function.
LineLoop=DIG
The received signal at this interface does not
go through the device (minimum penetration) but
is looped back out.
OtherLoop
Loopbacks that are not defined here.
InwardLoop=LLB
The sent signal at this interface is looped back
through the device.
LC
This loop is applicable only for HSSI interface, towards the router .
ToneInjection
This loop is applicable for analog voice (like FXS).
Context
- MIB
- ACE2002-MIB
- OID
.1.3.6.1.4.1.164.6.2.15.4.1.1.2- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- prtTestEntry
Syntax
Integer32
Values & Constraints
No enumerated values or constraints recorded.