acdDesc
ACD-DESC-MIB ·
.1.3.6.1.4.1.22420.1.1
Object
node
No description available.
Context
- MIB
- ACD-DESC-MIB
- OID
.1.3.6.1.4.1.22420.1.1- Type
- node
- Status
- current
- Children
- 18
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Child Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| acdDescNotifications | node | - | .1.3.6.1.4.1.22420.1.1.0 |
| acdDescCommercialName This string is to describe the type of device. | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.22420.1.1.1 |
| acdDescConnectorTable Table of all connectors info | table | - | .1.3.6.1.4.1.22420.1.1.10 |
| acdDescPwrTable Table of all Power Supplies | table | - | .1.3.6.1.4.1.22420.1.1.11 |
| acdDescTsTable Table of all Teperature Sensors. | table | - | .1.3.6.1.4.1.22420.1.1.12 |
| acdDescMIBObjects | node | - | .1.3.6.1.4.1.22420.1.1.15 |
| acdDescMacBaseAddr This is the Base of the EtherNID MAC addresses. | scalar | SNMPv2-TCMacAddress | .1.3.6.1.4.1.22420.1.1.2 |
| acdDescCpuUsageCurrent Indicates the current percentage of CPU usage. | scalar | percent Unsigned32 | .1.3.6.1.4.1.22420.1.1.20 |
| acdDescCpuUsageAverage15 Indicates the average percentage of CPU usage over the last 15 seconds.
This object range from (0..100). | scalar | percent Unsigned32 | .1.3.6.1.4.1.22420.1.1.21 |
| acdDescCpuUsageAverage30 Indicates the average percentage of CPU usage over the last 30 seconds.
This object range from (0..100). | scalar | percent Unsigned32 | .1.3.6.1.4.1.22420.1.1.22 |
| acdDescCpuUsageAverage60 Indicates the average percentage of CPU usage over the last 60 seconds.
This object range from (0..100). | scalar | percent Unsigned32 | .1.3.6.1.4.1.22420.1.1.23 |
| acdDescCpuUsageAverage900 Indicates the average percentage of CPU usage over the last 900
seconds. This object range from (0..100). | scalar | percent Unsigned32 | .1.3.6.1.4.1.22420.1.1.24 |
| acdDescUptime Number of seconds elapsed since boot. | scalar | Unsigned32 | .1.3.6.1.4.1.22420.1.1.25 |
| acdDescIdentifier Identifies the EtherNID on your network. | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.22420.1.1.3 |
| acdDescFirmwareVersion Indicates the version of the firmware currently loaded. | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.22420.1.1.4 |
| acdDescHardwareVersion Indicates the assembly ID of the hardware. | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.22420.1.1.5 |
| acdDescSerialNumber Indicates the serial number. | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.22420.1.1.6 |
| acdDescHardwareOptions Indicates the Hardware options. | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.22420.1.1.7 |