ACD-DESC-MIB Table View

Table-centric layout grouping table, row, and column objects.

Tables
3
Rows
3
Columns
15
.1.3.6.1.4.1.22420.1.1.10 · 1 row entry · 4 columns
Table of all connectors info
acdDescConnectorEntry entry .1.3.6.1.4.1.22420.1.1.10.1
This is the product connector definition.
Indexes
acdDescConnectorID
Column Syntax OID
acdDescConnectorID
Unique value for each connector. Starting to one from left to right.
Unsigned32
Constraints:
range: 1-4294967295
.1.3.6.1.4.1.22420.1.1.10.1.1
acdDescConnectorName
Identifies the connector on the silkscreen.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.22420.1.1.10.1.2
acdDescConnectorType
Describe the connector type, for instance an RJ-45 or an SFP.
Enumeration
Enumerated Values:
1other
2rj45
3rj45S
4db9
5bnc
6fAUI
7mAUI
8fiberSC
9fiberMIC
10fiberST
11telco
12mtrj
13hssdc
14fiberLC
.1.3.6.1.4.1.22420.1.1.10.1.3
acdDescConnectorPoESupport
This is to indicate if the port support PoE or not.
SNMPv2-TCTruthValue
Textual Convention: SNMPv2-TCTruthValue Enumeration
Type Values:
1true
2false
.1.3.6.1.4.1.22420.1.1.10.1.4
.1.3.6.1.4.1.22420.1.1.11 · 1 row entry · 4 columns
Table of all Power Supplies
acdDescPwrEntry entry .1.3.6.1.4.1.22420.1.1.11.1
This is the product available power supplies information.
Indexes
acdDescPwrID
Column Syntax OID
acdDescPwrID
Unique value for each power supply.
Unsigned32
Constraints:
range: 1-4294967295
.1.3.6.1.4.1.22420.1.1.11.1.1
acdDescPwrName
Identifies the power supply.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.22420.1.1.11.1.2
acdDescPwrType
Describe the Power Supply type.
Enumeration
Enumerated Values:
1pwrplus5volts
2pwrminus48volts
.1.3.6.1.4.1.22420.1.1.11.1.3
acdDescPwrPresent
This is to indicate if the power supply is present or not.
SNMPv2-TCTruthValue
Textual Convention: SNMPv2-TCTruthValue Enumeration
Type Values:
1true
2false
.1.3.6.1.4.1.22420.1.1.11.1.4
.1.3.6.1.4.1.22420.1.1.12 · 1 row entry · 7 columns
Table of all Teperature Sensors.
acdDescTsEntry entry .1.3.6.1.4.1.22420.1.1.12.1
This is the product available Temperature sensor information.
Indexes
acdDescTsID
Column Syntax OID
acdDescTsID
Unique value for each Temperature Sensor.
Unsigned32
Constraints:
range: 1-4294967295
.1.3.6.1.4.1.22420.1.1.12.1.1
acdDescTsCurrentTemp
Current temperature in Celsius around the temperature sensor.
On LT and LT-S units this value is truncated and does not
include the decimals.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.22420.1.1.12.1.2
acdDescTsFirstThres
Temperature value in Celsius to declare this threshold crossed.
On LT and LT-S units this value is truncated and does not
include the decimals.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.22420.1.1.12.1.3
acdDescTsFisrtThresPass
This is to indicate if the temperature cross the first threshold.
SNMPv2-TCTruthValue
Textual Convention: SNMPv2-TCTruthValue Enumeration
Type Values:
1true
2false
.1.3.6.1.4.1.22420.1.1.12.1.4
acdDescTsSecondThres
Temperature value in Celsius to declare this second threshold crossed.
On LT and LT-S units this value is truncated and does not
include the decimals.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.22420.1.1.12.1.5
acdDescTsSecondThresPass
This is to indicate if the temperature cross the second threshold.
SNMPv2-TCTruthValue
Textual Convention: SNMPv2-TCTruthValue Enumeration
Type Values:
1true
2false
.1.3.6.1.4.1.22420.1.1.12.1.6
acdDescTsLabel
Label of the temperature sensor.
OctetString
Constraints:
range: 1-63
.1.3.6.1.4.1.22420.1.1.12.1.7