ACD-DESC-MIB Table View
Table-centric layout grouping table, row, and column objects.
Tables
3
Rows
3
Columns
15
acdDescConnectorTable
table.1.3.6.1.4.1.22420.1.1.10
·
1 row entry
·
4 columns
Uses the accedian variant from
Command help
/opt/observium/mibs/accedian.
Walk acdDescConnectorTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'ACD-DESC-MIB' -M '/opt/observium/mibs/accedian:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ACD-DESC-MIB::acdDescConnectorTable'
Table of all connectors info
This is the product connector definition.
Indexes
| Column | Syntax | OID | ||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Unique value for each connector. Starting to one from left to right.
|
Unsigned32 Constraints: range: 1-4294967295 |
.1.3.6.1.4.1.22420.1.1.10.1.1 |
||||||||||||||||||||||||||||
|
Identifies the connector on the silkscreen.
|
SNMPv2-TCDisplayString Type Constraints: range: 0..255Description: Represents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of c… |
.1.3.6.1.4.1.22420.1.1.10.1.2 |
||||||||||||||||||||||||||||
|
Describe the connector type, for instance an RJ-45 or an SFP.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.22420.1.1.10.1.3 |
||||||||||||||||||||||||||||
|
This is to indicate if the port support PoE or not.
|
SNMPv2-TCTruthValue Type Values:
Description: Represents a boolean value. |
.1.3.6.1.4.1.22420.1.1.10.1.4 |
acdDescPwrTable
table.1.3.6.1.4.1.22420.1.1.11
·
1 row entry
·
4 columns
Uses the accedian variant from
Command help
/opt/observium/mibs/accedian.
Walk acdDescPwrTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'ACD-DESC-MIB' -M '/opt/observium/mibs/accedian:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ACD-DESC-MIB::acdDescPwrTable'
Table of all Power Supplies
This is the product available power supplies information.
Indexes
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
Unique value for each power supply.
|
Unsigned32 Constraints: range: 1-4294967295 |
.1.3.6.1.4.1.22420.1.1.11.1.1 |
||||
|
Identifies the power supply.
|
SNMPv2-TCDisplayString Type Constraints: range: 0..255Description: Represents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of c… |
.1.3.6.1.4.1.22420.1.1.11.1.2 |
||||
|
Describe the Power Supply type.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.22420.1.1.11.1.3 |
||||
|
This is to indicate if the power supply is present or not.
|
SNMPv2-TCTruthValue Type Values:
Description: Represents a boolean value. |
.1.3.6.1.4.1.22420.1.1.11.1.4 |
acdDescTsTable
table.1.3.6.1.4.1.22420.1.1.12
·
1 row entry
·
7 columns
Uses the accedian variant from
Command help
/opt/observium/mibs/accedian.
Walk acdDescTsTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'ACD-DESC-MIB' -M '/opt/observium/mibs/accedian:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ACD-DESC-MIB::acdDescTsTable'
Table of all Teperature Sensors.
This is the product available Temperature sensor information.
Indexes
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
Unique value for each Temperature Sensor.
|
Unsigned32 Constraints: range: 1-4294967295 |
.1.3.6.1.4.1.22420.1.1.12.1.1 |
||||
|
Current temperature in Celsius around the temperature sensor.
On LT and LT-S units this value is truncated and does not include the decimals. |
SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.22420.1.1.12.1.2 |
||||
|
Temperature value in Celsius to declare this threshold crossed.
On LT and LT-S units this value is truncated and does not include the decimals. |
SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.22420.1.1.12.1.3 |
||||
|
This is to indicate if the temperature cross the first threshold.
|
SNMPv2-TCTruthValue Type Values:
Description: Represents a boolean value. |
.1.3.6.1.4.1.22420.1.1.12.1.4 |
||||
|
Temperature value in Celsius to declare this second threshold crossed.
On LT and LT-S units this value is truncated and does not include the decimals. |
SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.22420.1.1.12.1.5 |
||||
|
This is to indicate if the temperature cross the second threshold.
|
SNMPv2-TCTruthValue Type Values:
Description: Represents a boolean value. |
.1.3.6.1.4.1.22420.1.1.12.1.6 |
||||
|
Label of the temperature sensor.
|
OctetString Constraints: range: 1-63 |
.1.3.6.1.4.1.22420.1.1.12.1.7 |