a3ComSysBridgePortReceiveMulticastLimitMultiplier

A3COM-SWITCHING-SYSTEMS-MIB · .1.3.6.1.4.1.43.29.4.10.3.1.29

Object

column mandatory Integer32
This variable determines the minimum setting for the multicast
limit threshold.  For example if this value equals 1000, and the
a3ComSysBridgePortReceiveMulticastLimit variable equals 2 then
no more than 2000 multicast frames per second will be forwarded 
by this port.

Context

MIB
A3COM-SWITCHING-SYSTEMS-MIB
OID
.1.3.6.1.4.1.43.29.4.10.3.1.29
Type
column
Access
readonly
Status
mandatory
Parent
a3ComSysBridgePortEntry

Walk the column to discover its indexed instances, or supply every index to read one instance.

Walk the column
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'A3COM-SWITCHING-SYSTEMS-MIB' -M '/opt/observium/mibs/a3com:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'A3COM-SWITCHING-SYSTEMS-MIB::a3ComSysBridgePortReceiveMulticastLimitMultiplier'
More examples
Read one indexed instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'A3COM-SWITCHING-SYSTEMS-MIB' -M '/opt/observium/mibs/a3com:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'A3COM-SWITCHING-SYSTEMS-MIB::a3ComSysBridgePortReceiveMulticastLimitMultiplier.<a3ComSysBridgePortBridgeIndex>.<a3ComSysBridgePortIndex>'
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'A3COM-SWITCHING-SYSTEMS-MIB' -M '/opt/observium/mibs/a3com:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'A3COM-SWITCHING-SYSTEMS-MIB::a3ComSysBridgePortReceiveMulticastLimitMultiplier'

Syntax

Source
SNMPv2-SMIInteger32
Base type
Integer32

Values & Constraints

Type Constraints
range: -2147483648..2147483647