a3ComFddiSMTHoldState
A3COM-SWITCHING-SYSTEMS-FDDI-MIB ·
.1.3.6.1.4.1.43.29.10.1.1.1.4
Object
column
mandatory
Enumeration
This variable indicates the current state of the Hold function. The value 'not-holding' is the default and initial value. The value must be set to 'not-holding' as part of Active-Actions and when the conditions causing 'holding-prm' or 'holding-sec' are no longer true. The value 'holding-prm' must be set when the condition (notTR-Flag & not RE-Flag & (PC-LS=QLS | LEM-Fail TNE>NS-Max | (not LS-Flag & TPC > T-Out))) is satisfied in state PC8:ACTIVE for the A Port. The value 'holding-sec' must be set when the condition (notTR-Flag & not RE-Flag & (PC-LS=QLS | LEM-Fail TNE>NS-Max | (not LS-Flag & TPC > T-Out))) is satisfied in state PC8:ACTIVE for the B Port.
Context
- MIB
- A3COM-SWITCHING-SYSTEMS-FDDI-MIB
- OID
.1.3.6.1.4.1.43.29.10.1.1.1.4- Type
- column
- Access
- readonly
- Status
- mandatory
- Parent
- a3ComFddiSMTEntry
Syntax
Enumeration
Values & Constraints
Enumerated Values
1 | not-implemented |
2 | not-holding |
3 | holding-prm |
4 | holding-sec |