h3cPOEThresholdACMimimum

A3COM-HUAWEI-POWER-ETH-EXT-MIB · .1.3.6.1.4.1.43.45.1.10.2.14.8.1.1

Object

scalar r/w OctetString
Input threshold AC minimum.
It is a read-write node.
The value of this node is 'OCTET STRING',
it is used to describe a float value.
So this string should fit the following rule:
1. This string should be terminated by '\0';
2. Every characters should be number or radix point;
3. The radix point should occur only once, and it should not
be the first or the last character of the string.
The value of this node should be smaller than 264.0V and larger than 90.0V.
And it should be smaller than the h3cPOEThresholdACMaximum.

Context

MIB
A3COM-HUAWEI-POWER-ETH-EXT-MIB
OID
.1.3.6.1.4.1.43.45.1.10.2.14.8.1.1
Type
scalar
Access
readwrite
Status
current
Parent
h3cPOEThresholdLimitObjs
Siblings
3

Syntax

OctetString

Values & Constraints

Object Constraints
range: 1-10

Related Objects

Sibling Objects