NBS-ODSYS-MIB Table View

Table-centric layout grouping table, row, and column objects.

Tables
4
Rows
4
Columns
63
.1.3.6.1.4.1.629.228.2.1 · 1 row entry · 4 columns
Uses the mrv variant from /opt/observium/mibs/mrv.
Command help
Walk nbsOdsysChasTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'NBS-ODSYS-MIB' -M '/opt/observium/mibs/mrv:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'NBS-ODSYS-MIB::nbsOdsysChasTable'
nbsOdsysChasEntry row .1.3.6.1.4.1.629.228.2.1.1
Information about a particular OptiDriver chassis.
Column Syntax OID
The nbsCmmcChassisIndex of this chassis
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.629.228.2.1.1.1
The maximum number of control cards that can be installed in this chassis
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.629.228.2.1.1.10
The number of power supply bays/slots in this chassis
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.629.228.2.1.1.20
The number of fan tray bays/slots in this chassis
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.629.228.2.1.1.30
.1.3.6.1.4.1.629.228.3.1 · 1 row entry · 11 columns
Uses the mrv variant from /opt/observium/mibs/mrv.
Command help
Walk nbsOdsysCcTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'NBS-ODSYS-MIB' -M '/opt/observium/mibs/mrv:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'NBS-ODSYS-MIB::nbsOdsysCcTable'
Information about OptiDriver chassis control/fpga cards
nbsOdsysCcEntry row .1.3.6.1.4.1.629.228.3.1.1
Status information for a particular control card slot/bay.
When a control card is present, it will also have entries
in nbsPartHardTable, nbsPartFirmTable, and nbsPartProgTable.

The events nbsOdsysTrapCcFai…
Column Syntax OID
The nbsCmmcChassisIndex of this control card's chassis
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.629.228.3.1.1.1
The control card slot/bay #
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.629.228.3.1.1.2
The nbsPartHardIfIndex of this Cc daughtercard's chassis
IF-MIBInterfaceIndex
Type Constraints:
range: 1..2147483647
Description:
A unique value, greater than zero, for each interface or
interface sub-layer in the managed system. It is
recommended that values are assigned contiguously starting
from 1. The value for each interface sub-layer must …
.1.3.6.1.4.1.629.228.3.1.1.10
The nbsPartHardPartIndex of this Cc daughtercard
NBS-MIBNbsTcPartIndex .1.3.6.1.4.1.629.228.3.1.1.11
Indicates the current temperature reading,
in degrees celsius
NBS-MIBNbsTcTemperature
Type Constraints:
range: -2147483648..1000
.1.3.6.1.4.1.629.228.3.1.1.30
Indicates level of current temperature reading with respect
to the CcTherm threshold objects below
NBS-MIBNbsTcStatusLevel
Type Values:
1notSupported
2statusLowError
3statusLowWarning
4statusGood
5statusHighWarning
6statusHighError
.1.3.6.1.4.1.629.228.3.1.1.40
Indicates the minimum functional operating temperature,
in degrees celsius
NBS-MIBNbsTcTemperature
Type Constraints:
range: -2147483648..1000
.1.3.6.1.4.1.629.228.3.1.1.41
Indicates the minimum safe operating temperature,
in degrees celsius
NBS-MIBNbsTcTemperature
Type Constraints:
range: -2147483648..1000
.1.3.6.1.4.1.629.228.3.1.1.42
Indicates the maximum safe operating temperature,
in degrees celsius
NBS-MIBNbsTcTemperature
Type Constraints:
range: -2147483648..1000
.1.3.6.1.4.1.629.228.3.1.1.43
Indicates the maximum functional operating temperature,
in degrees celsius
NBS-MIBNbsTcTemperature
Type Constraints:
range: -2147483648..1000
.1.3.6.1.4.1.629.228.3.1.1.44
Operational status of this daughtercard
NBS-MIBNbsTcStatusSimple
Type Values:
1notSupported
2bad
3good
4notInstalled
.1.3.6.1.4.1.629.228.3.1.1.50
.1.3.6.1.4.1.629.228.4.1 · 1 row entry · 12 columns
Uses the mrv variant from /opt/observium/mibs/mrv.
Command help
Walk nbsOdsysFtTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'NBS-ODSYS-MIB' -M '/opt/observium/mibs/mrv:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'NBS-ODSYS-MIB::nbsOdsysFtTable'
nbsOdsysFtEntry row .1.3.6.1.4.1.629.228.4.1.1
A particular chassis cooling assembly slot/bay.

Each installed fan tray also has entries in nbsPartHardTable.

The events nbsCmmcTrapFanFailure, nbsCmmcTrapFanRestored,
nbsCmmcTrapFanRemoved and…
Column Syntax OID
nbsCmmcChassisIndex of this fan tray's chassis
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.629.228.4.1.1.1
Fan tray bay/slot number, unique within this chassis
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.629.228.4.1.1.2
The value notSupported(1) indicates the fan tray is absent.
NBS-MIBNbsTcStatusSimple
Type Values:
1notSupported
2bad
3good
4notInstalled
.1.3.6.1.4.1.629.228.4.1.1.3
The nbsPartHardIfIndex of this fan tray's chassis
IF-MIBInterfaceIndex
Type Constraints:
range: 1..2147483647
Description:
A unique value, greater than zero, for each interface or
interface sub-layer in the managed system. It is
recommended that values are assigned contiguously starting
from 1. The value for each interface sub-layer must …
.1.3.6.1.4.1.629.228.4.1.1.10
The nbsPartHardPartIndex of this fan tray
NBS-MIBNbsTcPartIndex .1.3.6.1.4.1.629.228.4.1.1.11
The number of fans in this tray
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.629.228.4.1.1.20
Indicates the current temperature reading,
in degrees celsius
NBS-MIBNbsTcTemperature
Type Constraints:
range: -2147483648..1000
.1.3.6.1.4.1.629.228.4.1.1.30
Indicates level of current temperature reading with respect
to the FtTherm threshold objects below
NBS-MIBNbsTcStatusLevel
Type Values:
1notSupported
2statusLowError
3statusLowWarning
4statusGood
5statusHighWarning
6statusHighError
.1.3.6.1.4.1.629.228.4.1.1.40
Indicates the minimum functional operating temperature,
in degrees celsius
NBS-MIBNbsTcTemperature
Type Constraints:
range: -2147483648..1000
.1.3.6.1.4.1.629.228.4.1.1.41
Indicates the minimum safe operating temperature,
in degrees celsius
NBS-MIBNbsTcTemperature
Type Constraints:
range: -2147483648..1000
.1.3.6.1.4.1.629.228.4.1.1.42
Indicates the maximum safe operating temperature,
in degrees celsius
NBS-MIBNbsTcTemperature
Type Constraints:
range: -2147483648..1000
.1.3.6.1.4.1.629.228.4.1.1.43
Indicates the maximum functional operating temperature,
in degrees celsius
NBS-MIBNbsTcTemperature
Type Constraints:
range: -2147483648..1000
.1.3.6.1.4.1.629.228.4.1.1.44
.1.3.6.1.4.1.629.228.5.2 · 1 row entry · 36 columns
Uses the mrv variant from /opt/observium/mibs/mrv.
Command help
Walk nbsOdsysPsTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'NBS-ODSYS-MIB' -M '/opt/observium/mibs/mrv:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'NBS-ODSYS-MIB::nbsOdsysPsTable'
Information about OptiDriver chassis' power supplies
nbsOdsysPsEntry row .1.3.6.1.4.1.629.228.5.2.1
A particular power supply slot/bay.

Each installed power supply also has entries in
nbsPartHardTable.

The events nbsCmmcTrapPowerSupplyFailure,
nbsCmmcTrapPowerSupplyRestored, nbsCmmcTrapPowerS…
Column Syntax OID
The nbsCmmcChassisIndex of this power supply's chassis
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.629.228.5.2.1.1
Number of this power supply slot/bay
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.629.228.5.2.1.2
The value notSupported(1) indicates power supply is absent.
NBS-MIBNbsTcStatusSimple
Type Values:
1notSupported
2bad
3good
4notInstalled
.1.3.6.1.4.1.629.228.5.2.1.3
The nbsPartHardIfIndex of this power supply's chassis
IF-MIBInterfaceIndex
Type Constraints:
range: 1..2147483647
Description:
A unique value, greater than zero, for each interface or
interface sub-layer in the managed system. It is
recommended that values are assigned contiguously starting
from 1. The value for each interface sub-layer must …
.1.3.6.1.4.1.629.228.5.2.1.10
The nbsPartHardPartIndex of this power supply
NBS-MIBNbsTcPartIndex .1.3.6.1.4.1.629.228.5.2.1.11
Indicates how many internal fans this power supply has.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.629.228.5.2.1.30
Indicates the current temperature reading,
in degrees celsius
NBS-MIBNbsTcTemperature
Type Constraints:
range: -2147483648..1000
.1.3.6.1.4.1.629.228.5.2.1.40
Indicates level of current temperature reading with respect
to the PsTherm threshold objects below
NBS-MIBNbsTcStatusLevel
Type Values:
1notSupported
2statusLowError
3statusLowWarning
4statusGood
5statusHighWarning
6statusHighError
.1.3.6.1.4.1.629.228.5.2.1.41
Indicates the minimum functional operating temperature,
in degrees celsius
NBS-MIBNbsTcTemperature
Type Constraints:
range: -2147483648..1000
.1.3.6.1.4.1.629.228.5.2.1.42
Indicates the minimum safe operating temperature,
in degrees celsius
NBS-MIBNbsTcTemperature
Type Constraints:
range: -2147483648..1000
.1.3.6.1.4.1.629.228.5.2.1.43
Indicates the maximum safe operating temperature,
in degrees celsius
NBS-MIBNbsTcTemperature
Type Constraints:
range: -2147483648..1000
.1.3.6.1.4.1.629.228.5.2.1.44
Indicates the maximum functional operating temperature,
in degrees celsius
NBS-MIBNbsTcTemperature
Type Constraints:
range: -2147483648..1000
.1.3.6.1.4.1.629.228.5.2.1.45
Indicates the input voltage reading, in millivolts
NBS-MIBNbsTcMilliVolt
Type Constraints:
range: -1..1000000
.1.3.6.1.4.1.629.228.5.2.1.50
Indicates level of input voltage reading with respect
to the PsVIn threshold objects below
NBS-MIBNbsTcStatusLevel
Type Values:
1notSupported
2statusLowError
3statusLowWarning
4statusGood
5statusHighWarning
6statusHighError
.1.3.6.1.4.1.629.228.5.2.1.51
Indicates the minimum functional input voltage, in millivolts
NBS-MIBNbsTcMilliVolt
Type Constraints:
range: -1..1000000
.1.3.6.1.4.1.629.228.5.2.1.52
Indicates the minimum safe input voltage, in millivolts
NBS-MIBNbsTcMilliVolt
Type Constraints:
range: -1..1000000
.1.3.6.1.4.1.629.228.5.2.1.53
Indicates the maximum safe input voltage, in millivolts
NBS-MIBNbsTcMilliVolt
Type Constraints:
range: -1..1000000
.1.3.6.1.4.1.629.228.5.2.1.54
Indicates the maximum functional input voltage, in millivolts
NBS-MIBNbsTcMilliVolt
Type Constraints:
range: -1..1000000
.1.3.6.1.4.1.629.228.5.2.1.55
Indicates the output voltage reading, in millivolts
NBS-MIBNbsTcMilliVolt
Type Constraints:
range: -1..1000000
.1.3.6.1.4.1.629.228.5.2.1.60
Indicates level of output voltage reading with respect
to the PsVOut threshold objects below
NBS-MIBNbsTcStatusLevel
Type Values:
1notSupported
2statusLowError
3statusLowWarning
4statusGood
5statusHighWarning
6statusHighError
.1.3.6.1.4.1.629.228.5.2.1.61
Indicates the minimum functional output voltage, in millivolts
NBS-MIBNbsTcMilliVolt
Type Constraints:
range: -1..1000000
.1.3.6.1.4.1.629.228.5.2.1.62
Indicates the minimum safe output voltage, in millivolts
NBS-MIBNbsTcMilliVolt
Type Constraints:
range: -1..1000000
.1.3.6.1.4.1.629.228.5.2.1.63
Indicates the maximum safe output voltage, in millivolts
NBS-MIBNbsTcMilliVolt
Type Constraints:
range: -1..1000000
.1.3.6.1.4.1.629.228.5.2.1.64
Indicates the maximum functional output voltage, in millivolts
NBS-MIBNbsTcMilliVolt
Type Constraints:
range: -1..1000000
.1.3.6.1.4.1.629.228.5.2.1.65
Indicates the input current reading, in milliamps
NBS-MIBNbsTcMilliAmp
Type Constraints:
range: -1..1000000
.1.3.6.1.4.1.629.228.5.2.1.70
Indicates level of input current reading with respect
to the PsIIn threshold objects below
NBS-MIBNbsTcStatusLevel
Type Values:
1notSupported
2statusLowError
3statusLowWarning
4statusGood
5statusHighWarning
6statusHighError
.1.3.6.1.4.1.629.228.5.2.1.71
Indicates the minimum functional input current, in milliamps
NBS-MIBNbsTcMilliAmp
Type Constraints:
range: -1..1000000
.1.3.6.1.4.1.629.228.5.2.1.72
Indicates the minimum safe input current, in milliamps
NBS-MIBNbsTcMilliAmp
Type Constraints:
range: -1..1000000
.1.3.6.1.4.1.629.228.5.2.1.73
Indicates the maximum safe input current, in milliamps
NBS-MIBNbsTcMilliAmp
Type Constraints:
range: -1..1000000
.1.3.6.1.4.1.629.228.5.2.1.74
Indicates the maximum functional input current, in milliamps
NBS-MIBNbsTcMilliAmp
Type Constraints:
range: -1..1000000
.1.3.6.1.4.1.629.228.5.2.1.75
Indicates the output current, in milliamps
NBS-MIBNbsTcMilliAmp
Type Constraints:
range: -1..1000000
.1.3.6.1.4.1.629.228.5.2.1.80
Indicates level of output current reading with respect
to the PsIOut threshold objects below
NBS-MIBNbsTcStatusLevel
Type Values:
1notSupported
2statusLowError
3statusLowWarning
4statusGood
5statusHighWarning
6statusHighError
.1.3.6.1.4.1.629.228.5.2.1.81
Indicates the minimum functional output current, in milliamps
NBS-MIBNbsTcMilliAmp
Type Constraints:
range: -1..1000000
.1.3.6.1.4.1.629.228.5.2.1.82
Indicates the minimum safe output current, in milliamps
NBS-MIBNbsTcMilliAmp
Type Constraints:
range: -1..1000000
.1.3.6.1.4.1.629.228.5.2.1.83
Indicates the maximum safe output current, in milliamps
NBS-MIBNbsTcMilliAmp
Type Constraints:
range: -1..1000000
.1.3.6.1.4.1.629.228.5.2.1.84
Indicates the maximum functional output current, in milliamps
NBS-MIBNbsTcMilliAmp
Type Constraints:
range: -1..1000000
.1.3.6.1.4.1.629.228.5.2.1.85