NBS-ODSYS-MIB
Monitored by Observium For managing Opti-Driver systems.
Observium actively monitors this MIB
Observium uses this MIB in discovery or polling workflows on applicable devices.
Sensors
Explore Observium network monitoring
- Source file
NBS-ODSYS-MIB- Last revised
- Identity
nbsOdsysMib- Base OID
1.3.6.1.4.1.629.228
Imported Objects
| IF-MIB | InterfaceIndex |
| NBS-MIB | nbs NbsTcMilliAmp NbsTcMilliVolt NbsTcPartIndex NbsTcStatusLevel NbsTcStatusSimple NbsTcTemperature |
| SNMPv2-SMI | MODULE-IDENTITY (no object page) NOTIFICATION-TYPE (no object page) OBJECT-IDENTITY (no object page) OBJECT-TYPE (no object page) |
Net-SNMP examples using the mrv MIB directory Show commands
These commands use the standard Observium installation path and load the selected MIB variant before the RFC and Net-SNMP directories.
Translate the module identity
/usr/bin/snmptranslate -Pud -Ir -On -m 'NBS-ODSYS-MIB' -M '/opt/observium/mibs/mrv:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'NBS-ODSYS-MIB::nbsOdsysMib'
Walk the MIB subtree
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'NBS-ODSYS-MIB' -M '/opt/observium/mibs/mrv:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'NBS-ODSYS-MIB::nbsOdsysMib'
Objects (78)
5 directly used by Observium
Showing 78 of 78 objects
Object legend
Object type
Icons distinguish tables, entry rows, columns, scalars, and structural nodes.
SNMPv2-TCTruthValue
Syntax
Blue badges identify the value syntax. Connected badges read as defining module and convention.
IF-MIBifIndex
Table index
Green identifies an index object; yellow names its module when the index is defined elsewhere.
r/w
deprecated
obsolete
Access and status
r/w means read-write. Grey labels mark definitions retained for compatibility.
OBS ✓
Observium use
The indicator appears only when Observium directly references that object.
ifOperStatus
.1.3.6.1.2.1…
Names and OIDs
Object names link to their detail pages. Hover or focus a linked name or badge for available definition details.
.1.3.6.1.4.1.629.228 |
||
.1.3.6.1.4.1.629.228.100 |
||
.1.3.6.1.4.1.629.228.100.0 |
||
.1.3.6.1.4.1.629.228.2 |
||
.1.3.6.1.4.1.629.228.2.1 |
||
.1.3.6.1.4.1.629.228.2.1.1 |
||
.1.3.6.1.4.1.629.228.2.1.1.1 |
||
.1.3.6.1.4.1.629.228.2.1.1.10 |
||
.1.3.6.1.4.1.629.228.2.1.1.20 |
||
.1.3.6.1.4.1.629.228.2.1.1.30 |
||
.1.3.6.1.4.1.629.228.3 |
||
.1.3.6.1.4.1.629.228.3.1 |
||
.1.3.6.1.4.1.629.228.3.1.1 |
||
.1.3.6.1.4.1.629.228.3.1.1.1 |
||
.1.3.6.1.4.1.629.228.3.1.1.10 |
||
.1.3.6.1.4.1.629.228.3.1.1.11 |
||
.1.3.6.1.4.1.629.228.3.1.1.2 |
||
.1.3.6.1.4.1.629.228.3.1.1.30 |
||
.1.3.6.1.4.1.629.228.3.1.1.40 |
||
.1.3.6.1.4.1.629.228.3.1.1.41 |
||
.1.3.6.1.4.1.629.228.3.1.1.42 |
||
.1.3.6.1.4.1.629.228.3.1.1.43 |
||
.1.3.6.1.4.1.629.228.3.1.1.44 |
||
.1.3.6.1.4.1.629.228.3.1.1.50 |
||
.1.3.6.1.4.1.629.228.4 |
||
.1.3.6.1.4.1.629.228.4.1 |
||
.1.3.6.1.4.1.629.228.4.1.1 |
||
.1.3.6.1.4.1.629.228.4.1.1.1 |
||
.1.3.6.1.4.1.629.228.4.1.1.10 |
||
.1.3.6.1.4.1.629.228.4.1.1.11 |
||
.1.3.6.1.4.1.629.228.4.1.1.2 |
||
.1.3.6.1.4.1.629.228.4.1.1.20 |
||
.1.3.6.1.4.1.629.228.4.1.1.3 |
||
.1.3.6.1.4.1.629.228.4.1.1.30 |
||
.1.3.6.1.4.1.629.228.4.1.1.40 |
||
.1.3.6.1.4.1.629.228.4.1.1.41 |
||
.1.3.6.1.4.1.629.228.4.1.1.42 |
||
.1.3.6.1.4.1.629.228.4.1.1.43 |
||
.1.3.6.1.4.1.629.228.4.1.1.44 |
||
.1.3.6.1.4.1.629.228.5 |
||
.1.3.6.1.4.1.629.228.5.2 |
||
.1.3.6.1.4.1.629.228.5.2.1 |
||
.1.3.6.1.4.1.629.228.5.2.1.1 |
||
.1.3.6.1.4.1.629.228.5.2.1.10 |
||
.1.3.6.1.4.1.629.228.5.2.1.11 |
||
.1.3.6.1.4.1.629.228.5.2.1.2 |
||
.1.3.6.1.4.1.629.228.5.2.1.3 |
||
.1.3.6.1.4.1.629.228.5.2.1.30 |
||
|
|
.1.3.6.1.4.1.629.228.5.2.1.40 |
|
.1.3.6.1.4.1.629.228.5.2.1.41 |
||
.1.3.6.1.4.1.629.228.5.2.1.42 |
||
.1.3.6.1.4.1.629.228.5.2.1.43 |
||
.1.3.6.1.4.1.629.228.5.2.1.44 |
||
.1.3.6.1.4.1.629.228.5.2.1.45 |
||
|
|
.1.3.6.1.4.1.629.228.5.2.1.50 |
|
.1.3.6.1.4.1.629.228.5.2.1.51 |
||
.1.3.6.1.4.1.629.228.5.2.1.52 |
||
.1.3.6.1.4.1.629.228.5.2.1.53 |
||
.1.3.6.1.4.1.629.228.5.2.1.54 |
||
.1.3.6.1.4.1.629.228.5.2.1.55 |
||
|
|
.1.3.6.1.4.1.629.228.5.2.1.60 |
|
.1.3.6.1.4.1.629.228.5.2.1.61 |
||
.1.3.6.1.4.1.629.228.5.2.1.62 |
||
.1.3.6.1.4.1.629.228.5.2.1.63 |
||
.1.3.6.1.4.1.629.228.5.2.1.64 |
||
.1.3.6.1.4.1.629.228.5.2.1.65 |
||
|
|
.1.3.6.1.4.1.629.228.5.2.1.70 |
|
.1.3.6.1.4.1.629.228.5.2.1.71 |
||
.1.3.6.1.4.1.629.228.5.2.1.72 |
||
.1.3.6.1.4.1.629.228.5.2.1.73 |
||
.1.3.6.1.4.1.629.228.5.2.1.74 |
||
.1.3.6.1.4.1.629.228.5.2.1.75 |
||
|
|
.1.3.6.1.4.1.629.228.5.2.1.80 |
|
.1.3.6.1.4.1.629.228.5.2.1.81 |
||
.1.3.6.1.4.1.629.228.5.2.1.82 |
||
.1.3.6.1.4.1.629.228.5.2.1.83 |
||
.1.3.6.1.4.1.629.228.5.2.1.84 |
||
.1.3.6.1.4.1.629.228.5.2.1.85 |
Dependencies (7) 3 direct · 4 transitive Show tree and compile order Hide dependency details
Each imported module is resolved in the importing module's source directory first, then through the normal default-variant rules.
Dependency tree
Dependency-first compile order
- SNMPv2-SMIrfc
- SNMPv2-TCrfc
- IANAifType-MIBrfc
- SNMPv2-CONFrfc
- SNMPv2-MIBrfc
- IF-MIBrfc
- NBS-MIBmrv
- NBS-ODSYS-MIBmrvselected
Notifications / Traps (18)
| Name | OID | Description |
|---|---|---|
.1.3.6.1.4.1.629.228.100.0.131 |
Triggered when nbsOdsysCcOperationalStatus transitions to
bad (2) |
|
.1.3.6.1.4.1.629.228.100.0.132 |
Triggered when nbsOdsysCcOperationalStatus transitions to
good (3) |
|
.1.3.6.1.4.1.629.228.100.0.133 |
Triggered when control card is removed from chassis
|
|
.1.3.6.1.4.1.629.228.100.0.134 |
Triggered when control card is inserted into chassis
|
|
.1.3.6.1.4.1.629.228.100.0.30 |
Sent when nbsOdsysCcThermLevel changes to anything but
statusGood (4) |
|
.1.3.6.1.4.1.629.228.100.0.31 |
Sent when nbsOdsysCcThermLevel changes to statusGood (4)
|
|
.1.3.6.1.4.1.629.228.100.0.40 |
Sent when fan tray's nbsOdsysFtThermLevel changes to
anything but statusGood (4) |
|
.1.3.6.1.4.1.629.228.100.0.41 |
Sent when fan tray's nbsOdsysFtThermLevel changes to
statusGood (4) |
|
.1.3.6.1.4.1.629.228.100.0.50 |
Sent when power supply's nbsOdsysPsThermLevel changes to
anything but statusGood (4) |
|
.1.3.6.1.4.1.629.228.100.0.51 |
Sent when power supply's nbsOdsysPsThermLevel changes to
statusGood (4) |
|
.1.3.6.1.4.1.629.228.100.0.60 |
Sent when power supply's nbsOdsysPsVInLevel changes to
anything but statusGood (4) |
|
.1.3.6.1.4.1.629.228.100.0.61 |
Sent when power supply's nbsOdsysPsVInLevel changes to
statusGood (4) |
|
.1.3.6.1.4.1.629.228.100.0.70 |
Sent when power supply's nbsOdsysPsVOutLevel changes to
anything but statusGood (4) |
|
.1.3.6.1.4.1.629.228.100.0.71 |
Sent when power supply's nbsOdsysPsVOutLevel changes to
statusGood (4) |
|
.1.3.6.1.4.1.629.228.100.0.80 |
Sent when power supply's nbsOdsysPsIInLevel changes to
anything but statusGood (4) |
|
.1.3.6.1.4.1.629.228.100.0.81 |
Sent when power supply's nbsOdsysPsIInLevel changes to
statusGood (4) |
|
.1.3.6.1.4.1.629.228.100.0.90 |
Sent when power supply's nbsOdsysPsIOutLevel changes to
anything but statusGood (4) |
|
.1.3.6.1.4.1.629.228.100.0.91 |
Sent when power supply's nbsOdsysPsIOutLevel changes to
statusGood (4) |