NBS-ODSYS-MIB

Monitored by Observium
        For managing Opti-Driver systems.
    
Observium actively monitors this MIB
Observium uses this MIB in discovery or polling workflows on applicable devices.
Sensors
Explore Observium network monitoring
Source file
NBS-ODSYS-MIB
Last revised
Identity
nbsOdsysMib
Base OID
1.3.6.1.4.1.629.228
Imported Objects
IF-MIB InterfaceIndex
NBS-MIB nbs NbsTcMilliAmp NbsTcMilliVolt NbsTcPartIndex NbsTcStatusLevel NbsTcStatusSimple NbsTcTemperature
SNMPv2-SMI MODULE-IDENTITY (no object page) NOTIFICATION-TYPE (no object page) OBJECT-IDENTITY (no object page) OBJECT-TYPE (no object page)
Net-SNMP examples using the mrv MIB directory Show commands

These commands use the standard Observium installation path and load the selected MIB variant before the RFC and Net-SNMP directories.

Translate the module identity
/usr/bin/snmptranslate -Pud -Ir -On -m 'NBS-ODSYS-MIB' -M '/opt/observium/mibs/mrv:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'NBS-ODSYS-MIB::nbsOdsysMib'
Walk the MIB subtree
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'NBS-ODSYS-MIB' -M '/opt/observium/mibs/mrv:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'NBS-ODSYS-MIB::nbsOdsysMib'
How SNMP, Net-SNMP, MIB paths, and variants work
Objects (78)
5 directly used by Observium
.1.3.6.1.4.1.629.228
.1.3.6.1.4.1.629.228.100
.1.3.6.1.4.1.629.228.100.0
.1.3.6.1.4.1.629.228.2
.1.3.6.1.4.1.629.228.2.1
.1.3.6.1.4.1.629.228.2.1.1
.1.3.6.1.4.1.629.228.2.1.1.1
.1.3.6.1.4.1.629.228.2.1.1.10
.1.3.6.1.4.1.629.228.2.1.1.20
.1.3.6.1.4.1.629.228.2.1.1.30
.1.3.6.1.4.1.629.228.3
.1.3.6.1.4.1.629.228.3.1
.1.3.6.1.4.1.629.228.3.1.1
.1.3.6.1.4.1.629.228.3.1.1.1
.1.3.6.1.4.1.629.228.3.1.1.10
.1.3.6.1.4.1.629.228.3.1.1.11
.1.3.6.1.4.1.629.228.3.1.1.2
.1.3.6.1.4.1.629.228.3.1.1.30
.1.3.6.1.4.1.629.228.3.1.1.40
.1.3.6.1.4.1.629.228.3.1.1.41
.1.3.6.1.4.1.629.228.3.1.1.42
.1.3.6.1.4.1.629.228.3.1.1.43
.1.3.6.1.4.1.629.228.3.1.1.44
.1.3.6.1.4.1.629.228.3.1.1.50
.1.3.6.1.4.1.629.228.4
.1.3.6.1.4.1.629.228.4.1
.1.3.6.1.4.1.629.228.4.1.1
.1.3.6.1.4.1.629.228.4.1.1.1
.1.3.6.1.4.1.629.228.4.1.1.10
.1.3.6.1.4.1.629.228.4.1.1.11
.1.3.6.1.4.1.629.228.4.1.1.2
.1.3.6.1.4.1.629.228.4.1.1.20
.1.3.6.1.4.1.629.228.4.1.1.3
.1.3.6.1.4.1.629.228.4.1.1.30
.1.3.6.1.4.1.629.228.4.1.1.40
.1.3.6.1.4.1.629.228.4.1.1.41
.1.3.6.1.4.1.629.228.4.1.1.42
.1.3.6.1.4.1.629.228.4.1.1.43
.1.3.6.1.4.1.629.228.4.1.1.44
.1.3.6.1.4.1.629.228.5
.1.3.6.1.4.1.629.228.5.2
.1.3.6.1.4.1.629.228.5.2.1
.1.3.6.1.4.1.629.228.5.2.1.1
.1.3.6.1.4.1.629.228.5.2.1.10
.1.3.6.1.4.1.629.228.5.2.1.11
.1.3.6.1.4.1.629.228.5.2.1.2
.1.3.6.1.4.1.629.228.5.2.1.3
.1.3.6.1.4.1.629.228.5.2.1.30
.1.3.6.1.4.1.629.228.5.2.1.40
.1.3.6.1.4.1.629.228.5.2.1.41
.1.3.6.1.4.1.629.228.5.2.1.42
.1.3.6.1.4.1.629.228.5.2.1.43
.1.3.6.1.4.1.629.228.5.2.1.44
.1.3.6.1.4.1.629.228.5.2.1.45
.1.3.6.1.4.1.629.228.5.2.1.50
.1.3.6.1.4.1.629.228.5.2.1.51
.1.3.6.1.4.1.629.228.5.2.1.52
.1.3.6.1.4.1.629.228.5.2.1.53
.1.3.6.1.4.1.629.228.5.2.1.54
.1.3.6.1.4.1.629.228.5.2.1.55
.1.3.6.1.4.1.629.228.5.2.1.60
.1.3.6.1.4.1.629.228.5.2.1.61
.1.3.6.1.4.1.629.228.5.2.1.62
.1.3.6.1.4.1.629.228.5.2.1.63
.1.3.6.1.4.1.629.228.5.2.1.64
.1.3.6.1.4.1.629.228.5.2.1.65
.1.3.6.1.4.1.629.228.5.2.1.70
.1.3.6.1.4.1.629.228.5.2.1.71
.1.3.6.1.4.1.629.228.5.2.1.72
.1.3.6.1.4.1.629.228.5.2.1.73
.1.3.6.1.4.1.629.228.5.2.1.74
.1.3.6.1.4.1.629.228.5.2.1.75
.1.3.6.1.4.1.629.228.5.2.1.80
.1.3.6.1.4.1.629.228.5.2.1.81
.1.3.6.1.4.1.629.228.5.2.1.82
.1.3.6.1.4.1.629.228.5.2.1.83
.1.3.6.1.4.1.629.228.5.2.1.84
.1.3.6.1.4.1.629.228.5.2.1.85
Dependencies (7) 3 direct · 4 transitive Show tree and compile order Hide dependency details

Each imported module is resolved in the importing module's source directory first, then through the normal default-variant rules.

Dependency tree
Dependency-first compile order
  1. SNMPv2-SMIrfc
  2. SNMPv2-TCrfc
  3. IANAifType-MIBrfc
  4. SNMPv2-CONFrfc
  5. SNMPv2-MIBrfc
  6. IF-MIBrfc
  7. NBS-MIBmrv
  8. NBS-ODSYS-MIBmrvselected
Notifications / Traps (18)
NameOIDDescription
.1.3.6.1.4.1.629.228.100.0.131
Triggered when nbsOdsysCcOperationalStatus transitions to
bad (2)
.1.3.6.1.4.1.629.228.100.0.132
Triggered when nbsOdsysCcOperationalStatus transitions to
good (3)
.1.3.6.1.4.1.629.228.100.0.133
Triggered when control card is removed from chassis
.1.3.6.1.4.1.629.228.100.0.134
Triggered when control card is inserted into chassis
.1.3.6.1.4.1.629.228.100.0.30
Sent when nbsOdsysCcThermLevel changes to anything but
statusGood (4)
.1.3.6.1.4.1.629.228.100.0.31
Sent when nbsOdsysCcThermLevel changes to statusGood (4)
.1.3.6.1.4.1.629.228.100.0.40
Sent when fan tray's nbsOdsysFtThermLevel changes to
anything but statusGood (4)
.1.3.6.1.4.1.629.228.100.0.41
Sent when fan tray's nbsOdsysFtThermLevel changes to
statusGood (4)
.1.3.6.1.4.1.629.228.100.0.50
Sent when power supply's nbsOdsysPsThermLevel changes to
anything but statusGood (4)
.1.3.6.1.4.1.629.228.100.0.51
Sent when power supply's nbsOdsysPsThermLevel changes to
statusGood (4)
.1.3.6.1.4.1.629.228.100.0.60
Sent when power supply's nbsOdsysPsVInLevel changes to
anything but statusGood (4)
.1.3.6.1.4.1.629.228.100.0.61
Sent when power supply's nbsOdsysPsVInLevel changes to
statusGood (4)
.1.3.6.1.4.1.629.228.100.0.70
Sent when power supply's nbsOdsysPsVOutLevel changes to
anything but statusGood (4)
.1.3.6.1.4.1.629.228.100.0.71
Sent when power supply's nbsOdsysPsVOutLevel changes to
statusGood (4)
.1.3.6.1.4.1.629.228.100.0.80
Sent when power supply's nbsOdsysPsIInLevel changes to
anything but statusGood (4)
.1.3.6.1.4.1.629.228.100.0.81
Sent when power supply's nbsOdsysPsIInLevel changes to
statusGood (4)
.1.3.6.1.4.1.629.228.100.0.90
Sent when power supply's nbsOdsysPsIOutLevel changes to
anything but statusGood (4)
.1.3.6.1.4.1.629.228.100.0.91
Sent when power supply's nbsOdsysPsIOutLevel changes to
statusGood (4)