G6-HARDWARE-MIB Table View
Table-centric layout grouping table, row, and column objects.
Tables
10
Rows
10
Columns
84
cableTestConfigTable
table.1.3.6.1.4.1.3181.10.6.1.31.6
·
1 row entry
·
6 columns
Uses the microsens variant from
Command help
/opt/observium/mibs/microsens.
Walk cableTestConfigTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'G6-HARDWARE-MIB' -M '/opt/observium/mibs/microsens:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'G6-HARDWARE-MIB::cableTestConfigTable'
The cable tester allows for detection of copper cable faults and can even detect where the fault is located.
Indexes
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
|
Automatically generated
|
Integer32 Constraints: range: 0-24 |
.1.3.6.1.4.1.3181.10.6.1.31.6.1.1 |
||||||
|
When enabled a cable test is performed each time the link goes down. The test is only performed for copper ports or dual media ports in copper mode.
|
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.3181.10.6.1.31.6.1.2 |
||||||
|
When the cable termination status changes an event can be raised.
|
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.3181.10.6.1.31.6.1.3 |
||||||
|
Select a value up to 508 which is used to decide between a connected cable and a remotely disconnected cable. With actively terminated data ports, the detection is difficult and precise setup is required. Please refer t…
|
Integer32r/w Constraints: range: 0-65535 |
.1.3.6.1.4.1.3181.10.6.1.31.6.1.4 |
||||||
|
Choose value to prevent oscillation when reflection value is slightly shifting.
|
Integer32r/w Constraints: range: 0-65535 |
.1.3.6.1.4.1.3181.10.6.1.31.6.1.5 |
||||||
|
May be used to manually start a cable test. ATTENTION: If the port is in link up status it will be forced to link down first. This will disrupt the current data traffic. Therefore, type start_test_now = CONFIRM.
|
SNMPv2-TCDisplayStringr/w Type Constraints: range: 0..255Description: Represents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of c… |
.1.3.6.1.4.1.3181.10.6.1.31.6.1.6 |
ioSignalConfigTable
table.1.3.6.1.4.1.3181.10.6.1.31.7
·
1 row entry
·
10 columns
Uses the microsens variant from
Command help
/opt/observium/mibs/microsens.
Walk ioSignalConfigTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'G6-HARDWARE-MIB' -M '/opt/observium/mibs/microsens:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'G6-HARDWARE-MIB::ioSignalConfigTable'
Indexes
| Column | Syntax | OID | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Automatically generated
|
Integer32 Constraints: range: 0-0 |
.1.3.6.1.4.1.3181.10.6.1.31.7.1.1 |
||||||||||||
|
Permit setting of io signal LEDs and relays to static or blink blink mode for increased visualization.
|
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.3181.10.6.1.31.7.1.2 |
||||||||||||
|
When this function is activated the external alarm input 1 is monitored. Note: alarm inputs are not available in all product versions.
|
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.3181.10.6.1.31.7.1.3 |
||||||||||||
|
A customer specific name can be specified for input 1. This name will appear in the associated event messages.
|
SNMPv2-TCDisplayStringr/w Type Constraints: range: 0..255Description: Represents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of c… |
.1.3.6.1.4.1.3181.10.6.1.31.7.1.4 |
||||||||||||
|
When this function is activated the external alarm input 2 is monitored. Note: alarm inputs are not available in all product versions.
|
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.3181.10.6.1.31.7.1.5 |
||||||||||||
|
A customer specific name can be specified for input 2. This name will appear in the associated event messages.
|
SNMPv2-TCDisplayStringr/w Type Constraints: range: 0..255Description: Represents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of c… |
.1.3.6.1.4.1.3181.10.6.1.31.7.1.6 |
||||||||||||
|
Defines on which condition the alarm relay 1 is activated. Note: alarm relays are not available in all product versions.
|
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.3181.10.6.1.31.7.1.7 |
||||||||||||
|
A customer specific name can be specified for alarm output 1. This name will appear in the associated event messages.
|
SNMPv2-TCDisplayStringr/w Type Constraints: range: 0..255Description: Represents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of c… |
.1.3.6.1.4.1.3181.10.6.1.31.7.1.8 |
||||||||||||
|
Defines on which condition the alarm relay 2 is activated. Note: alarm relays are not available in all product versions.
|
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.3181.10.6.1.31.7.1.9 |
||||||||||||
|
A customer specific name can be specified for alarm output 2. This name will appear in the associated event messages.
|
SNMPv2-TCDisplayStringr/w Type Constraints: range: 0..255Description: Represents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of c… |
.1.3.6.1.4.1.3181.10.6.1.31.7.1.10 |
moduleInfoTable
table.1.3.6.1.4.1.3181.10.6.1.31.109
·
1 row entry
·
8 columns
Uses the microsens variant from
Command help
/opt/observium/mibs/microsens.
Walk moduleInfoTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'G6-HARDWARE-MIB' -M '/opt/observium/mibs/microsens:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'G6-HARDWARE-MIB::moduleInfoTable'
This section indicates which modules are inserted in the optional extension slots.
Indexes
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
|
Automatically generated
|
Integer32 Constraints: range: 0-3 |
.1.3.6.1.4.1.3181.10.6.1.31.109.1.1 |
||||||
|
Identfies the general type of module.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.3181.10.6.1.31.109.1.2 |
||||||
|
The article number of the module in this slot.
|
SNMPv2-TCDisplayString Type Constraints: range: 0..255Description: Represents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of c… |
.1.3.6.1.4.1.3181.10.6.1.31.109.1.3 |
||||||
|
The serial number of the module in this slot.
|
SNMPv2-TCDisplayString Type Constraints: range: 0..255Description: Represents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of c… |
.1.3.6.1.4.1.3181.10.6.1.31.109.1.4 |
||||||
|
This device hardware revision number.
|
SNMPv2-TCDisplayString Type Constraints: range: 0..255Description: Represents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of c… |
.1.3.6.1.4.1.3181.10.6.1.31.109.1.5 |
||||||
|
MICROSENS project number.
|
SNMPv2-TCDisplayString Type Constraints: range: 0..255Description: Represents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of c… |
.1.3.6.1.4.1.3181.10.6.1.31.109.1.6 |
||||||
|
Lists all slots contained in this module.
|
SNMPv2-TCDisplayString Type Constraints: range: 0..255Description: Represents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of c… |
.1.3.6.1.4.1.3181.10.6.1.31.109.1.7 |
||||||
|
Feature summary of the module.
|
SNMPv2-TCDisplayString Type Constraints: range: 0..255Description: Represents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of c… |
.1.3.6.1.4.1.3181.10.6.1.31.109.1.8 |
slotInfoTable
table.1.3.6.1.4.1.3181.10.6.1.31.110
·
1 row entry
·
4 columns
Uses the microsens variant from
Command help
/opt/observium/mibs/microsens.
Walk slotInfoTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'G6-HARDWARE-MIB' -M '/opt/observium/mibs/microsens:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'G6-HARDWARE-MIB::slotInfoTable'
This section indicates which modules are inserted in the optional extension slots.
Indexes
| Column | Syntax | OID | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Automatically generated
|
Integer32 Constraints: range: 0-7 |
.1.3.6.1.4.1.3181.10.6.1.31.110.1.1 |
||||||||||||||
|
General type of board function
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.3181.10.6.1.31.110.1.2 |
||||||||||||||
|
This identifies the board type for internal operation.
|
SNMPv2-SMIUnsigned32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.3181.10.6.1.31.110.1.3 |
||||||||||||||
|
Version bits from hardware or backplane.
|
Integer32 Constraints: range: 0-255 |
.1.3.6.1.4.1.3181.10.6.1.31.110.1.4 |
portInfoTable
table.1.3.6.1.4.1.3181.10.6.1.31.111
·
1 row entry
·
10 columns
Uses the microsens variant from
Command help
/opt/observium/mibs/microsens.
Walk portInfoTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'G6-HARDWARE-MIB' -M '/opt/observium/mibs/microsens:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'G6-HARDWARE-MIB::portInfoTable'
Used to map physical to logical port ids.
Indexes
| Column | Syntax | OID | ||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Automatically generated
|
Integer32 Constraints: range: 0-24 |
.1.3.6.1.4.1.3181.10.6.1.31.111.1.1 |
||||||||||||||||||||||||||
|
Describes on which system slot this port index is located.
|
Integer32 Constraints: range: 0-255 |
.1.3.6.1.4.1.3181.10.6.1.31.111.1.2 |
||||||||||||||||||||||||||
|
Describes on which switch port this port index is located.
|
Integer32 Constraints: range: 0-255 |
.1.3.6.1.4.1.3181.10.6.1.31.111.1.3 |
||||||||||||||||||||||||||
|
Slot number as seen by customer.
|
Integer32 Constraints: range: 0-255 |
.1.3.6.1.4.1.3181.10.6.1.31.111.1.4 |
||||||||||||||||||||||||||
|
Port number as seen by customer.
|
Integer32 Constraints: range: 0-255 |
.1.3.6.1.4.1.3181.10.6.1.31.111.1.5 |
||||||||||||||||||||||||||
|
Slot and port representation as used in SNMP. Formula is Slot*100 + Port.
|
Integer32 Constraints: range: 0-65535 |
.1.3.6.1.4.1.3181.10.6.1.31.111.1.6 |
||||||||||||||||||||||||||
|
Port instance counting from 0 to number of ports
|
Integer32 Constraints: range: 0-255 |
.1.3.6.1.4.1.3181.10.6.1.31.111.1.7 |
||||||||||||||||||||||||||
|
Port number as used internally. Ports may not be in sequential order.
|
Integer32 Constraints: range: 0-255 |
.1.3.6.1.4.1.3181.10.6.1.31.111.1.8 |
||||||||||||||||||||||||||
|
Identifies port as copper or optical. Also used for snmp ifType definition
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.3181.10.6.1.31.111.1.9 |
||||||||||||||||||||||||||
|
Describes which functions the port can support.
|
Bits Enumerated Values:
|
.1.3.6.1.4.1.3181.10.6.1.31.111.1.10 |
portLedsTable
table.1.3.6.1.4.1.3181.10.6.1.31.112
·
1 row entry
·
5 columns
Uses the microsens variant from
Command help
/opt/observium/mibs/microsens.
Walk portLedsTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'G6-HARDWARE-MIB' -M '/opt/observium/mibs/microsens:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'G6-HARDWARE-MIB::portLedsTable'
This section indicates the state of all port related LEDs.
Indexes
| Column | Syntax | OID | ||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Automatically generated
|
Integer32 Constraints: range: 0-31 |
.1.3.6.1.4.1.3181.10.6.1.31.112.1.1 |
||||||||||||||||||
|
Ethernet Link LED.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.3181.10.6.1.31.112.1.2 |
||||||||||||||||||
|
Ethernet Link LED.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.3181.10.6.1.31.112.1.3 |
||||||||||||||||||
|
Power over Ethernet LED. For optical ports this indicates signal detect status.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.3181.10.6.1.31.112.1.4 |
||||||||||||||||||
|
Power over Ethernet LED. For optical ports this indicates signal detect status.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.3181.10.6.1.31.112.1.5 |
deviceLedsTable
table.1.3.6.1.4.1.3181.10.6.1.31.113
·
1 row entry
·
21 columns
Uses the microsens variant from
Command help
/opt/observium/mibs/microsens.
Walk deviceLedsTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'G6-HARDWARE-MIB' -M '/opt/observium/mibs/microsens:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'G6-HARDWARE-MIB::deviceLedsTable'
This section indicates the state of all LEDs which are not port related. Please note: Not every unit offers all LEDs.
Indexes
| Column | Syntax | OID | ||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Automatically generated
|
Integer32 Constraints: range: 0-0 |
.1.3.6.1.4.1.3181.10.6.1.31.113.1.1 |
||||||||||||||||||
|
This status corresponds to 'sys' LED on some devices.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.3181.10.6.1.31.113.1.2 |
||||||||||||||||||
|
This status corresponds to 'sys' LED on some devices.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.3181.10.6.1.31.113.1.3 |
||||||||||||||||||
|
Displays external management activity.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.3181.10.6.1.31.113.1.4 |
||||||||||||||||||
|
Displays external management activity.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.3181.10.6.1.31.113.1.5 |
||||||||||||||||||
|
This status corresponds to 'on' LED on some devices.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.3181.10.6.1.31.113.1.6 |
||||||||||||||||||
|
This status corresponds to 'on' LED on some devices.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.3181.10.6.1.31.113.1.7 |
||||||||||||||||||
|
Alternative power input LED.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.3181.10.6.1.31.113.1.8 |
||||||||||||||||||
|
Alternative power input LED.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.3181.10.6.1.31.113.1.9 |
||||||||||||||||||
|
This LED is used when ring protection is enabled.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.3181.10.6.1.31.113.1.10 |
||||||||||||||||||
|
This LED is used when ring protection is enabled.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.3181.10.6.1.31.113.1.11 |
||||||||||||||||||
|
This LED is used when ring protection is enabled.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.3181.10.6.1.31.113.1.12 |
||||||||||||||||||
|
This LED is used when ring protection is enabled.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.3181.10.6.1.31.113.1.13 |
||||||||||||||||||
|
Indicates status of alarm input 1.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.3181.10.6.1.31.113.1.14 |
||||||||||||||||||
|
Indicates status of alarm input 1.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.3181.10.6.1.31.113.1.15 |
||||||||||||||||||
|
Indicates status of alarm input 2.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.3181.10.6.1.31.113.1.16 |
||||||||||||||||||
|
Indicates status of alarm input 2.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.3181.10.6.1.31.113.1.17 |
||||||||||||||||||
|
Indicates status of alarm relay output 1.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.3181.10.6.1.31.113.1.18 |
||||||||||||||||||
|
Indicates status of alarm relay output 1.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.3181.10.6.1.31.113.1.19 |
||||||||||||||||||
|
Indicates status of alarm relay output 2.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.3181.10.6.1.31.113.1.20 |
||||||||||||||||||
|
Indicates status of alarm relay output 2.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.3181.10.6.1.31.113.1.21 |
cableTestStatusTable
table.1.3.6.1.4.1.3181.10.6.1.31.114
·
1 row entry
·
12 columns
Uses the microsens variant from
Command help
/opt/observium/mibs/microsens.
Walk cableTestStatusTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'G6-HARDWARE-MIB' -M '/opt/observium/mibs/microsens:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'G6-HARDWARE-MIB::cableTestStatusTable'
This table display the result of the last cable test. Values are only available for copper ports while a link is down and if the cable test function is enabled.
Indexes
| Column | Syntax | OID | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Automatically generated
|
Integer32 Constraints: range: 0-24 |
.1.3.6.1.4.1.3181.10.6.1.31.114.1.1 |
||||||||||||||
|
Indicates the time when this record was last updated.
|
SNMPv2-TCDisplayString Type Constraints: range: 0..255Description: Represents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of c… |
.1.3.6.1.4.1.3181.10.6.1.31.114.1.2 |
||||||||||||||
|
Indicates line termination test results for wire pair 0 (Pins 1/2)
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.3181.10.6.1.31.114.1.3 |
||||||||||||||
|
Distance to fault on wire pair 0 in centimeters. Indicates 0 when no fault is detected or the function is unused.
|
Integer32 Constraints: range: 0-65535 |
.1.3.6.1.4.1.3181.10.6.1.31.114.1.4 |
||||||||||||||
|
Indicates line termination test results for wire pair 1 (Pins 3/6)
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.3181.10.6.1.31.114.1.5 |
||||||||||||||
|
Distance to fault on wire pair 1 in centimeters. Indicates 0 when no fault is detected or the function is unused.
|
Integer32 Constraints: range: 0-65535 |
.1.3.6.1.4.1.3181.10.6.1.31.114.1.6 |
||||||||||||||
|
Indicates line termination test results for wire pair 2 (Pins 4/5)
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.3181.10.6.1.31.114.1.7 |
||||||||||||||
|
Distance to fault on wire pair 2 in centimeters. Indicates 0 when no fault is detected or the function is unused.
|
Integer32 Constraints: range: 0-65535 |
.1.3.6.1.4.1.3181.10.6.1.31.114.1.8 |
||||||||||||||
|
Indicates line termination test results for wire pair 3 (Pins 7/8)
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.3181.10.6.1.31.114.1.9 |
||||||||||||||
|
Distance to fault on wire pair 3 in centimeters. Indicates 0 when no fault is detected or the function is unused.
|
Integer32 Constraints: range: 0-65535 |
.1.3.6.1.4.1.3181.10.6.1.31.114.1.10 |
||||||||||||||
|
A unitless value that indicates a measure of reflection level. For difficult to detect actively terminated devices perform a measurement with remotely plugged-in and then unplugged cable. Note the reflection values an c…
|
Integer32 Constraints: range: 0-65535 |
.1.3.6.1.4.1.3181.10.6.1.31.114.1.11 |
||||||||||||||
|
Indicates the concluded status summary.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.3181.10.6.1.31.114.1.12 |
ioSignalStatusTable
table.1.3.6.1.4.1.3181.10.6.1.31.115
·
1 row entry
·
5 columns
Uses the microsens variant from
Command help
/opt/observium/mibs/microsens.
Walk ioSignalStatusTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'G6-HARDWARE-MIB' -M '/opt/observium/mibs/microsens:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'G6-HARDWARE-MIB::ioSignalStatusTable'
This section is only used for devices which offer external signal inputs and outputs.
Indexes
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
Automatically generated
|
Integer32 Constraints: range: 0-0 |
.1.3.6.1.4.1.3181.10.6.1.31.115.1.1 |
||||
|
Indicates true when the input 1 is logically active.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.3181.10.6.1.31.115.1.2 |
||||
|
Indicates true when the input 2 is logically active.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.3181.10.6.1.31.115.1.3 |
||||
|
Indicates true when the output 1 relay is activated.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.3181.10.6.1.31.115.1.4 |
||||
|
Indicates true when the output 2 relay is activated.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.3181.10.6.1.31.115.1.5 |
tcamStatusTable
table.1.3.6.1.4.1.3181.10.6.1.31.116
·
1 row entry
·
3 columns
Uses the microsens variant from
Command help
/opt/observium/mibs/microsens.
Walk tcamStatusTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'G6-HARDWARE-MIB' -M '/opt/observium/mibs/microsens:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'G6-HARDWARE-MIB::tcamStatusTable'
The TCAM is a programmable wire speed packet filter. The filter is controlled by the system automatically. This table indicates which filters have been set.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
Automatically generated
|
Integer32 Constraints: range: 0-255 |
.1.3.6.1.4.1.3181.10.6.1.31.116.1.1 |
|
Reflects the name of the control file associated with this tcam entry.
|
SNMPv2-TCDisplayString Type Constraints: range: 0..255Description: Represents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of c… |
.1.3.6.1.4.1.3181.10.6.1.31.116.1.2 |
|
Descriptive text what explains what this tcam entry will do.
|
SNMPv2-TCDisplayString Type Constraints: range: 0..255Description: Represents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of c… |
.1.3.6.1.4.1.3181.10.6.1.31.116.1.3 |