This MIB module defines the portion of the SNMP enterprise MIBs under Enterasys Networks' enterprise OID pertaining to the Flow Limiting feature. |
etsysModules | ENTERASYS-MIB-NAMES |
etsysMultiAuthStationAddr, etsysMultiAuthStationAddrType | ENTERASYS-MULTI-AUTH-MIB |
ifName, ifIndex | IF-MIB |
EnabledStatus | P-BRIDGE-MIB |
MODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP | SNMPv2-CONF |
MODULE-IDENTITY, Gauge32, TimeTicks, Unsigned32, NOTIFICATION-TYPE, OBJECT-TYPE | SNMPv2-SMI |
TruthValue, TEXTUAL-CONVENTION | SNMPv2-TC |
Name | Base Type | Values/Constraints |
---|---|---|
generateNotification(0), dropExcessFlows(1), createDiscardFlows(2), disableInterface(3) | ||
userPort(1), serverPort(2), aggregatedUserPort(3), interSwitchLink(4), unspecified(5) | ||
none(1), l2(2), l3(3), l4(4) |
![]() | .1.3.6.1.4.1.5624.1.2.43 | |
![]() | .1.3.6.1.4.1.5624.1.2.43.1 | |
![]() | .1.3.6.1.4.1.5624.1.2.43.1.0 | |
![]() | .1.3.6.1.4.1.5624.1.2.43.1.1 | |
![]() | .1.3.6.1.4.1.5624.1.2.43.1.1.1 | |
![]() | .1.3.6.1.4.1.5624.1.2.43.1.1.2 | |
![]() | .1.3.6.1.4.1.5624.1.2.43.1.1.3 | |
![]() | .1.3.6.1.4.1.5624.1.2.43.1.1.4 | |
![]() | .1.3.6.1.4.1.5624.1.2.43.1.1.5 | |
![]() | .1.3.6.1.4.1.5624.1.2.43.1.1.6 | |
![]() | .1.3.6.1.4.1.5624.1.2.43.1.1.7 | |
![]() | .1.3.6.1.4.1.5624.1.2.43.1.2 | |
![]() | .1.3.6.1.4.1.5624.1.2.43.1.2.1 | |
![]() | .1.3.6.1.4.1.5624.1.2.43.1.2.1.1 | |
![]() | .1.3.6.1.4.1.5624.1.2.43.1.2.1.1.1 | |
![]() | .1.3.6.1.4.1.5624.1.2.43.1.2.1.1.2 | |
![]() | .1.3.6.1.4.1.5624.1.2.43.1.2.1.1.3 | |
![]() | .1.3.6.1.4.1.5624.1.2.43.1.2.1.1.4 | |
![]() | .1.3.6.1.4.1.5624.1.2.43.1.2.1.1.5 | |
![]() | .1.3.6.1.4.1.5624.1.2.43.1.2.1.1.6 | |
![]() | .1.3.6.1.4.1.5624.1.2.43.1.2.1.1.7 | |
![]() | .1.3.6.1.4.1.5624.1.2.43.1.2.1.1.8 | |
![]() | .1.3.6.1.4.1.5624.1.2.43.1.3 | |
![]() | .1.3.6.1.4.1.5624.1.2.43.1.3.1 | |
![]() | .1.3.6.1.4.1.5624.1.2.43.1.3.1.1 | |
![]() | .1.3.6.1.4.1.5624.1.2.43.1.3.1.1.1 | |
![]() | .1.3.6.1.4.1.5624.1.2.43.1.3.1.1.10 | |
![]() | .1.3.6.1.4.1.5624.1.2.43.1.3.1.1.11 | |
![]() | .1.3.6.1.4.1.5624.1.2.43.1.3.1.1.12 | |
![]() | .1.3.6.1.4.1.5624.1.2.43.1.3.1.1.13 | |
![]() | .1.3.6.1.4.1.5624.1.2.43.1.3.1.1.14 | |
![]() | .1.3.6.1.4.1.5624.1.2.43.1.3.1.1.2 | |
![]() | .1.3.6.1.4.1.5624.1.2.43.1.3.1.1.3 | |
![]() | .1.3.6.1.4.1.5624.1.2.43.1.3.1.1.4 | |
![]() | .1.3.6.1.4.1.5624.1.2.43.1.3.1.1.5 | |
![]() | .1.3.6.1.4.1.5624.1.2.43.1.3.1.1.6 | |
![]() | .1.3.6.1.4.1.5624.1.2.43.1.3.1.1.7 | |
![]() | .1.3.6.1.4.1.5624.1.2.43.1.3.1.1.8 | |
![]() | .1.3.6.1.4.1.5624.1.2.43.1.3.1.1.9 | |
![]() | .1.3.6.1.4.1.5624.1.2.43.1.4 | |
![]() | .1.3.6.1.4.1.5624.1.2.43.1.4.1 | |
![]() | .1.3.6.1.4.1.5624.1.2.43.1.4.1.1 | |
![]() | .1.3.6.1.4.1.5624.1.2.43.1.4.1.1.1 | |
![]() | .1.3.6.1.4.1.5624.1.2.43.1.4.1.1.2 | |
![]() | .1.3.6.1.4.1.5624.1.2.43.1.4.1.1.3 | |
![]() | .1.3.6.1.4.1.5624.1.2.43.1.4.1.1.4 | |
![]() | .1.3.6.1.4.1.5624.1.2.43.1.4.1.1.5 | |
![]() | .1.3.6.1.4.1.5624.1.2.43.1.4.1.1.6 | |
![]() | .1.3.6.1.4.1.5624.1.2.43.1.4.1.1.7 | |
![]() | .1.3.6.1.4.1.5624.1.2.43.2 | |
![]() | .1.3.6.1.4.1.5624.1.2.43.2.1 | |
![]() | .1.3.6.1.4.1.5624.1.2.43.2.2 |
Name | OID | Description |
---|---|---|
.1.3.6.1.4.1.5624.1.2.43.1.0.1 | An etsysFlowlimitingFlowCountActionLimit1 notification indicates that the number of flows on the interface has exceeded the currently configured limit in the associated etsysFlowLimitingClassFlowCountActionLimit1 for the interface. | |
.1.3.6.1.4.1.5624.1.2.43.1.0.10 | An etsysFlowlimitingFlowCountLimit2User notification indicates that the number of flows for the user has exceeded the currently configured limit in the associated etsysFlowLimitingClassFlowCountActionLimit2 for the user. | |
.1.3.6.1.4.1.5624.1.2.43.1.0.2 | An etsysFlowlimitingFlowCountActionLimit2 notification indicates that the number of flows on the interface has exceeded the currently configured limit in the associated etsysFlowLimitingClassFlowCountActionLimit2 for the interface. | |
.1.3.6.1.4.1.5624.1.2.43.1.0.3 | An etsysFlowLimitingSetupRateNotifyLimit notification indicates that the flow setup rate on the interface has exceeded the currently configured limit for generating a notification. | |
.1.3.6.1.4.1.5624.1.2.43.1.0.4 | An etsysFlowLimitingSetupRateExceeded notification indicates that the flow setup rate on the interface has exceeded the currently configured limit for taking an action. | |
.1.3.6.1.4.1.5624.1.2.43.1.0.5 | An etsysFlowlimitingFlowCountActionLimit1 notification indicates that the number of flows on the interface has exceeded the currently configured limit in the associated etsysFlowLimitingClassFlowCountActionLimit1 for the interface. | |
.1.3.6.1.4.1.5624.1.2.43.1.0.6 | An etsysFlowlimitingFlowCountActionLimit2 notification indicates that the number of flows on the interface has exceeded the currently configured limit in the associated etsysFlowLimitingClassFlowCountActionLimit2 for the interface. | |
.1.3.6.1.4.1.5624.1.2.43.1.0.7 | An etsysFlowLimitingSetupRateNotifyLimit notification indicates that the flow setup rate on the interface has exceeded the currently configured limit for generating a notification. | |
.1.3.6.1.4.1.5624.1.2.43.1.0.8 | An etsysFlowLimitingSetupRateExceeded notification indicates that the flow setup rate on the interface has exceeded the currently configured limit for taking an action. | |
.1.3.6.1.4.1.5624.1.2.43.1.0.9 | An etsysFlowlimitingFlowCountLimit1User notification indicates that the number of flows for the user has exceeded the currently configured limit in the associated etsysFlowLimitingClassFlowCountActionLimit1 for the user. |