ENERGY-OBJECT-MIB Table View

Table-centric layout grouping table, row, and column objects.

Tables
5
Rows
5
Columns
33
.1.3.6.1.2.1.229.1.1 · 1 row entry · 1 columns
Uses the rfc variant from /opt/observium/mibs/rfc.
Command help
Walk eoMeterCapabilitiesTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'ENERGY-OBJECT-MIB' -M '/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ENERGY-OBJECT-MIB::eoMeterCapabilitiesTable'
This table is useful for helping applications determine
the monitoring capabilities supported by the local
management agents.  It is possible for applications to
know which tables are usable without going through a
trial-and-error process.
eoMeterCapabilitiesEntry row .1.3.6.1.2.1.229.1.1.1
An entry describes the metering capability of an Energy
Object.
Column Syntax OID
An indication of the energy-monitoring capabilities
supported by this agent. This object use a BITS syntax
and indicates the MIB groups supported by the probe. By
reading the value of this object, it is possible to
de…
Bits
Enumerated Values:
0none
1powermetering
2energymetering
3powerattributes
.1.3.6.1.2.1.229.1.1.1.1

eoPowerTable

table
.1.3.6.1.2.1.229.1.2 · 1 row entry · 10 columns
Uses the rfc variant from /opt/observium/mibs/rfc.
Command help
Walk eoPowerTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'ENERGY-OBJECT-MIB' -M '/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ENERGY-OBJECT-MIB::eoPowerTable'
This table lists Energy Objects.
eoPowerEntry row .1.3.6.1.2.1.229.1.2.1
An entry describes the power usage of an Energy Object.
Column Syntax OID
This object indicates the power measured for the Energy
Object. For alternating current, this value is obtained
as an average over fixed number of AC cycles. This value
is specified in SI units of watts with the magni…
wattsSNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.2.1.229.1.2.1.1
This object indicates the rated maximum consumption for
the fully populated Energy Object. The nameplate power
requirements are the maximum power numbers given in SI
watts and, in almost all cases, are well above the
e…
wattsSNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.229.1.2.1.2
The magnitude of watts for the usage value in eoPower
and eoPowerNameplate.
UnitMultiplier
Type Values:
-24yocto
-21zepto
-18atto
-15femto
-12pico
-9nano
-6micro
-3milli
0units
3kilo
6mega
9giga
12tera
15peta
18exa
21zetta
24yotta
.1.3.6.1.2.1.229.1.2.1.3
This object indicates a percentage value, in hundredths of a
percent, representing the assumed accuracy of the usage
reported by eoPower. For example, the value 1010 means
the reported usage is accurate to +/- 10.1 per…
hundredths of percentInteger32
Constraints:
range: 0-10000
.1.3.6.1.2.1.229.1.2.1.4
This object specifies how the usage value reported by
eoPower was obtained:

- unavailable(1): Indicates that the usage is not
available. In such a case, the eoPower value must be 0
for devices that canno…
Enumeration
Enumerated Values:
1unavailable
2unknown
3actual
4estimated
5static
.1.3.6.1.2.1.229.1.2.1.5
This object indicates whether the eoPower for the
Energy Object reports alternating current 'ac', direct
current 'dc', or that the current type is unknown.
Enumeration
Enumerated Values:
1ac
2dc
3unknown
.1.3.6.1.2.1.229.1.2.1.6
This object indicates the source of power measurement
and can be useful when modeling the power usage of

attached devices. The power measurement can be performed
by the entity itself or the power measure…
SNMPv2-TCTruthValue
Type Values:
1true
2false
Description:
Represents a boolean value.
.1.3.6.1.2.1.229.1.2.1.7
This object specifies the desired Power State and the
Power State Set for the Energy Object. Note that other(0)
is not a Power State Set and unknown(255) is not a Power
State as such, but simply an indication that the …
IANAPowerStateSet-MIBPowerStateSetr/w
Type Values:
0other
255unknown
256ieee1621
257ieee1621Off
258ieee1621Sleep
259ieee1621On
512dmtf
513dmtfOn
514dmtfSleepLight
515dmtfSleepDeep
516dmtfOffHard
517dmtfOffSoft
518dmtfHibernate
519dmtfPowerOffSoft
520dmtfPowerOffHard
521dmtfMasterBusReset
522dmtfDiagnosticInterrapt
523dmtfOffSoftGraceful
524dmtfOffHardGraceful
525dmtfMasterBusResetGraceful
526dmtfPowerCycleOffSoftGraceful
527dmtfPowerCycleHardGraceful
1024eman
1025emanMechOff
1026emanSoftOff
1027emanHibernate
1028emanSleep
1029emanStandby
1030emanReady
1031emanLowMinus
1032emanLow
1033emanMediumMinus
1034emanMedium
1035emanHighMinus
1036emanHigh
.1.3.6.1.2.1.229.1.2.1.8
This object specifies the current operational Power
State and the Power State Set for the Energy Object.
other(0) is not a Power State Set and unknown(255) is not
a Power State as such, but simply an indication that the…
IANAPowerStateSet-MIBPowerStateSet
Type Values:
0other
255unknown
256ieee1621
257ieee1621Off
258ieee1621Sleep
259ieee1621On
512dmtf
513dmtfOn
514dmtfSleepLight
515dmtfSleepDeep
516dmtfOffHard
517dmtfOffSoft
518dmtfHibernate
519dmtfPowerOffSoft
520dmtfPowerOffHard
521dmtfMasterBusReset
522dmtfDiagnosticInterrapt
523dmtfOffSoftGraceful
524dmtfOffHardGraceful
525dmtfMasterBusResetGraceful
526dmtfPowerCycleOffSoftGraceful
527dmtfPowerCycleHardGraceful
1024eman
1025emanMechOff
1026emanSoftOff
1027emanHibernate
1028emanSleep
1029emanStandby
1030emanReady
1031emanLowMinus
1032emanLow
1033emanMediumMinus
1034emanMedium
1035emanHighMinus
1036emanHigh
.1.3.6.1.2.1.229.1.2.1.9
This string object describes the reason for the

eoPowerAdminState transition. Alternatively, this string
may contain with the entity that configured this Energy
Object to this Power State.
RMON-MIBOwnerStringr/w
Type Constraints:
range: 0..127
.1.3.6.1.2.1.229.1.2.1.10
.1.3.6.1.2.1.229.1.3 · 1 row entry · 5 columns
Uses the rfc variant from /opt/observium/mibs/rfc.
Command help
Walk eoPowerStateTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'ENERGY-OBJECT-MIB' -M '/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ENERGY-OBJECT-MIB::eoPowerStateTable'
This table enumerates the maximum power usage, in watts,
for every single supported Power State of each Energy
Object.
          
This table has cross-reference with the eoPowerTable,
containing rows describing each Power State for the
corresponding Energy Object.  For every Energy Object in
the eoPowerTable, there is a corresponding entry in this
table.
eoPowerStateEntry row .1.3.6.1.2.1.229.1.3.1
A eoPowerStateEntry extends a corresponding
eoPowerEntry. This entry displays max usage values at
every single possible Power State supported by the Energy
Object.
For example, given the values of a Energy Object
corre…
Column Syntax OID
This object specifies the index of the Power State of
the Energy Object within a Power State Set. The semantics
of the specific Power State can be obtained from the
Power State Set definition.
IANAPowerStateSet-MIBPowerStateSet
Type Values:
0other
255unknown
256ieee1621
257ieee1621Off
258ieee1621Sleep
259ieee1621On
512dmtf
513dmtfOn
514dmtfSleepLight
515dmtfSleepDeep
516dmtfOffHard
517dmtfOffSoft
518dmtfHibernate
519dmtfPowerOffSoft
520dmtfPowerOffHard
521dmtfMasterBusReset
522dmtfDiagnosticInterrapt
523dmtfOffSoftGraceful
524dmtfOffHardGraceful
525dmtfMasterBusResetGraceful
526dmtfPowerCycleOffSoftGraceful
527dmtfPowerCycleHardGraceful
1024eman
1025emanMechOff
1026emanSoftOff
1027emanHibernate
1028emanSleep
1029emanStandby
1030emanReady
1031emanLowMinus
1032emanLow
1033emanMediumMinus
1034emanMedium
1035emanHighMinus
1036emanHigh
.1.3.6.1.2.1.229.1.3.1.1
This object indicates the maximum power for the Energy
Object at the particular Power State. This value is
specified in SI units of watts with the magnitude of the
units (milliwatts, kilowatts, etc.) indicated separate…
wattsSNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.2.1.229.1.3.1.2
The magnitude of watts for the usage value in
eoPowerStateMaxPower.
UnitMultiplier
Type Values:
-24yocto
-21zepto
-18atto
-15femto
-12pico
-9nano
-6micro
-3milli
0units
3kilo
6mega
9giga
12tera
15peta
18exa
21zetta
24yotta
.1.3.6.1.2.1.229.1.3.1.3
This object indicates the total time in hundredths
of a second that the Energy Object has been in this power
state since the last reset, as specified in the
sysUpTime.
SNMPv2-SMITimeTicks
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.229.1.3.1.4
This object indicates how often the Energy Object has
entered this power state, since the last reset of the
device as specified in the sysUpTime.
SNMPv2-SMICounter32
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.229.1.3.1.5
.1.3.6.1.2.1.229.1.4 · 1 row entry · 8 columns
Uses the rfc variant from /opt/observium/mibs/rfc.
Command help
Walk eoEnergyParametersTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'ENERGY-OBJECT-MIB' -M '/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ENERGY-OBJECT-MIB::eoEnergyParametersTable'
This table is used to configure the parameters for
energy measurement collection in the table eoEnergyTable.
This table allows the configuration of different
measurement settings on the same Energy Object.
Implementation of this table only makes sense for Energy
Objects that an eoPowerMeasurementCaliber of actual.
eoEnergyParametersEntry row .1.3.6.1.2.1.229.1.4.1
An entry controls an energy measurement in
eoEnergyTable.
Column Syntax OID
This object specifies the index of the Energy Parameters
setting for collection of energy measurements for an
Energy Object. An Energy Object can have multiple
eoEnergyParametersIndex, depending on the capabilities of
Integer32
Constraints:
range: 1-2147483647
.1.3.6.1.2.1.229.1.4.1.2
This object indicates the length of time in hundredths
of a second over which to compute the average
eoEnergyConsumed measurement in the eoEnergyTable table.
The computation is based on the Energy Object's internal
samp…
SNMPv2-TCTimeIntervalr/w
Type Constraints:
range: 0..2147483647
Description:
A period of time, measured in units of 0.01 seconds.
.1.3.6.1.2.1.229.1.4.1.3
The number of intervals maintained in the eoEnergyTable.
Each interval is characterized by a specific
eoEnergyCollectionStartTime, used as an index to the
table eoEnergyTable. Whenever the maximum number of
entries is …
SNMPv2-SMIUnsigned32r/w
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.229.1.4.1.4
A control object to define the mode of interval
calculation for the computation of the average
eoEnergyConsumed or eoEnergyProvided measurement in the
eoEnergyTable table.

A mode of period(1) specifies no…
Enumerationr/w
Enumerated Values:
1period
2sliding
3total
.1.3.6.1.2.1.229.1.4.1.5
The length of the duration window between the starting
time of one sliding window and the next starting time in
hundredths of seconds, used to compute the average of
eoEnergyConsumed, eoEnergyProvided measurements in th…
SNMPv2-TCTimeIntervalr/w
Type Constraints:
range: 0..2147483647
Description:
A period of time, measured in units of 0.01 seconds.
.1.3.6.1.2.1.229.1.4.1.6
The sampling rate, in milliseconds, at which the Energy
Object should poll power usage in order to compute the
average eoEnergyConsumed, eoEnergyProvided measurements
in the table eoEnergyTable. The Energy Object shoul…
MillisecondsSNMPv2-SMIUnsigned32r/w
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.229.1.4.1.7
This variable indicates the storage type for this row.
SNMPv2-TCStorageTyper/w
Type Values:
1other
2volatile
3nonVolatile
4permanent
5readOnly
Description:
Describes the memory realization of a conceptual row. A
row which is volatile(2) is lost upon reboot. A row which
is either nonVolatile(3), permanent(4) or readOnly(5), is
backed up by stable storage. A row which is …
.1.3.6.1.2.1.229.1.4.1.8
The status of this row. The eoEnergyParametersStatus is
used to start or stop energy usage logging. An entry
status may not be active(1) unless all objects in the
entry have an appropriate value. If this object is no…
SNMPv2-TCRowStatusr/w
Type Values:
1active
2notInService
3notReady
4createAndGo
5createAndWait
6destroy
Description:
The RowStatus textual convention is used to manage the
creation and deletion of conceptual rows, and is used as the
value of the SYNTAX clause for the status column of a
conceptual row (as described in Section 7.7.1 of …
.1.3.6.1.2.1.229.1.4.1.9
.1.3.6.1.2.1.229.1.5 · 1 row entry · 9 columns
Uses the rfc variant from /opt/observium/mibs/rfc.
Command help
Walk eoEnergyTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'ENERGY-OBJECT-MIB' -M '/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ENERGY-OBJECT-MIB::eoEnergyTable'
This table lists Energy Object energy measurements.
Entries in this table are only created if the
corresponding value of object eoPowerMeasurementCaliber
is active(3), i.e., if the power is actually metered.
eoEnergyEntry row .1.3.6.1.2.1.229.1.5.1
An entry describing energy measurements.
Column Syntax OID
The time (in hundredths of a second) since the
network management portion of the system was last
re-initialized, as specified in the sysUpTime RFC 3418.
This object specifies the start time of the energy
measurement sam…
hundredths of a secondSNMPv2-SMITimeTicks
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.229.1.5.1.1
This object indicates the energy consumed in units of
watt-hours for the Energy Object over the defined
interval. This value is specified in the common billing
units of watt-hours with the magnitude of watt-hours
kWh, …
Watt-hoursSNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.229.1.5.1.2
This object indicates the energy produced in units of
watt-hours for the Energy Object over the defined
interval.

This value is specified in the common billing units of
watt-hours with the magnitude of wa…
Watt-hoursSNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.229.1.5.1.3
This object indicates the difference of the energy
consumed and energy produced for an Energy Object in
units of watt-hours for the Energy Object over the
defined interval. This value is specified in the common
billing…
Watt-hoursSNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.229.1.5.1.4
This object is the magnitude of watt-hours for the
energy field in eoEnergyConsumed, eoEnergyProvided,
eoEnergyStored, eoEnergyMaxConsumed, and
eoEnergyMaxProduced.
UnitMultiplier
Type Values:
-24yocto
-21zepto
-18atto
-15femto
-12pico
-9nano
-6micro
-3milli
0units
3kilo
6mega
9giga
12tera
15peta
18exa
21zetta
24yotta
.1.3.6.1.2.1.229.1.5.1.5
This object indicates a percentage accuracy, in hundredths
of a percent, of Energy usage reporting. eoEnergyAccuracy
is applicable to all Energy measurements in the
eoEnergyTable.

For example, 1010 means…
hundredths of percentInteger32
Constraints:
range: 0-10000
.1.3.6.1.2.1.229.1.5.1.6
This object is the maximum energy observed in
eoEnergyConsumed since the monitoring started or was
reinitialized. This value is specified in the common
billing units of watt-hours with the magnitude of
watt-hours (kWh,…
Watt-hoursSNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.229.1.5.1.7
This object is the maximum energy ever observed in
eoEnergyEnergyProduced since the monitoring started. This
value is specified in the units of watt-hours with the
magnitude of watt-hours (kWh, MWh, etc.) indicated
sep…
Watt-hoursSNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.229.1.5.1.8
The value of sysUpTime RFC 3418 on the most recent
occasion at which any one or more of this entity's energy
counters in this table suffered a discontinuity:
eoEnergyConsumed, eoEnergyProvided or eoEnergyStored. If
no …
SNMPv2-TCTimeStamp
Based On: SNMPv2-SMITimeTicks
Description:
The value of the sysUpTime object at which a specific
occurrence happened. The specific occurrence must be

defined in the description of any object defined using this
type.

If sysUpTime is reset t…