Rack name has changed.
This trap signifies that an agent or utility has changed the name
of the rack. Each of the server blades in each of the enclosure
within the rack will be updated to reflect the new rack name.
It may take several minutes for the rack name change to be
propagated throughout the entire rack.
User Action: None.
cpqRackEnclosureNameChanged
.1.3.6.1.4.1.232.0.22002
The enclosure name has changed.
This trap signifies that an agent or utility has changed the name
of an enclosure within the rack. Each of the components
within the rack will be updated to reflect the new enclosure name.
It may take several minutes for the enclosure name change to be
propagated throughout the entire enclosure.
User Action: None.
cpqRackEnclosureRemoved
.1.3.6.1.4.1.232.0.22003
The enclosure has been removed.
This trap signifies that an enclosure has been removed from
the rack.
User Action: None.
cpqRackEnclosureInserted
.1.3.6.1.4.1.232.0.22004
The enclosure has been inserted.
This trap signifies that an enclosure has been inserted into
the rack.
User Action: None.
cpqRackEnclosureTempFailed
.1.3.6.1.4.1.232.0.22005
The enclosure temperature status has been set to failed.
This trap signifies that a enclosure temperature sensor has
been tripped indicating an overheat condition.
User Action: Shutdown the enclosure and possibly the rack
as soon as possible. Ensure all fans are working properly and
that air flow in the rack has not been blocked.
cpqRackEnclosureTempDegraded
.1.3.6.1.4.1.232.0.22006
The enclosure temperature status has been set to degraded.
This trap signifies that an enclosure temperature sensor has
been tripped indicating a possible overheat condition.
User Action: Shutdown the enclosure and possibly the rack
as soon as possible. Ensure all fans are working properly and
that air flow in the rack has not been blocked.
cpqRackEnclosureTempOk
.1.3.6.1.4.1.232.0.22007
The enclosure temperature status has been set to ok.
This trap signifies that an enclosure temperature sensor has
returned to normal.
User Action: None.
cpqRackEnclosureFanFailed
.1.3.6.1.4.1.232.0.22008
The enclosure fan status has been set to failed.
This trap signifies that an enclosure fan has failed and
no other fans in the redundant fan group are operating.
This may result in overheating of the enclosure.
User Action: Replace the fan as soon as possible.
cpqRackEnclosureFanDegraded
.1.3.6.1.4.1.232.0.22009
The enclosure fan status has been set to degraded.
This trap signifies that an enclosure fan has failed but
other fans in the redundant fan group are still operating.
This may result in overheating of the enclosure.
User Action: Replace the fan as soon as possible.
cpqRackEnclosureFanOk
.1.3.6.1.4.1.232.0.22010
The enclosure fan status has been set to ok.
This trap signifies that an enclosure fan has returned
to normal operation.
User Action: None.
cpqRackEnclosureFanRemoved
.1.3.6.1.4.1.232.0.22011
The enclosure fan has been removed.
User Action: None.
cpqRackEnclosureFanInserted
.1.3.6.1.4.1.232.0.22012
The enclosure fan has been inserted.
User Action: None.
cpqRackPowerSupplyFailed
.1.3.6.1.4.1.232.0.22013
The power supply status has been set to failed.
This trap signifies that a power supply has failed.
User Action: Replace the power supply as soon as possible.
cpqRackPowerSupplyDegraded
.1.3.6.1.4.1.232.0.22014
The power supply status has been set to degraded.
This trap signifies that a power supply has degraded.
User Action: Replace the power supply as soon as possible.
cpqRackPowerSupplyOk
.1.3.6.1.4.1.232.0.22015
The power supply status has been set to ok.
This trap signifies that a power supply has returned to normal
operation.
User Action: None.
cpqRackPowerSupplyRemoved
.1.3.6.1.4.1.232.0.22016
The power supply has been removed.
User Action: None.
cpqRackPowerSupplyInserted
.1.3.6.1.4.1.232.0.22017
The power supply has been inserted.
User Action: None.
cpqRackPowerSubsystemNotRedundant
.1.3.6.1.4.1.232.0.22018
The rack power subsystem is no longer in a redundant state.
User Action: Replace any failed power supplies as soon as possible
to return the system to a redundant state.
cpqRackPowerSubsystemLineVoltageProblem
.1.3.6.1.4.1.232.0.22019
The rack power supply detected an input line voltage problem.
User Action: Check the power input for the power supply or replace
any failed power supplies as soon as possible.
cpqRackPowerSubsystemOverloadCondition
.1.3.6.1.4.1.232.0.22020
The rack power subsystem overload condition.
User Action: Replace any failed power supplies as soon as possible
to return the system to a redundant state.
cpqRackPowerShedAutoShutdown
.1.3.6.1.4.1.232.0.22021
Server shutdown due to power shedding.
The server blade was shutdown due to a lack of power.
User Action: Check power connections or add power supplies.
cpqRackServerPowerOnFailedNotRedundant
.1.3.6.1.4.1.232.0.22022
Server power on prevented to preserve redundancy.
There is not enough power to power on the server blade and
maintain redundancy for the other blades in the enclosure.
User Action: Check power connections or add power supplies.
cpqRackServerPowerOnFailedNotEnoughPower
.1.3.6.1.4.1.232.0.22023
Inadequate power to power on.
There is not enough power to power on the server blade.
User Action: Check power connections or add power supplies.
cpqRackServerPowerOnFailedEnclosureNotFound
.1.3.6.1.4.1.232.0.22024
Inadequate power to power on.
There is not enough power to power on the server blade. The
server enclosure micro-controller was not found.
User Action: Check server enclosure connections or add power supplies.
cpqRackServerPowerOnFailedPowerChassisNotFound
.1.3.6.1.4.1.232.0.22025
Inadequate power to power on.
There is not enough power to power on the server blade. The
power enclosure micro-controller was not found.
User Action: Check power enclosure connections or add power supplies.
cpqRackServerPowerOnManualOverride
.1.3.6.1.4.1.232.0.22026
Server power on via manual override.
The server blade was powered on by a manual override.
User Action: None.
cpqRackFuseOpen
.1.3.6.1.4.1.232.0.22027
Fuse open.
The fuse has been tripped.
User Action: Check enclosure and / or blade power connections and
reset the fuse.
cpqRackServerBladeRemoved
.1.3.6.1.4.1.232.0.22028
Server blade removed.
The server blade has been removed from the enclosure.
User Action: None.
cpqRackServerBladeInserted
.1.3.6.1.4.1.232.0.22029
Server blade inserted.
The server blade has been inserted into the enclosure.
User Action: None.
cpqRackPowerChassisNotLoadBalanced
.1.3.6.1.4.1.232.0.22030
Power subsystem not load balanced.
The power subsystem is out of balance for this power enclosure.
User Action: Check the power enclosure and power supplies. Replace
any failed or degraded power supplies. Add additional power supplies
if needed.
cpqRackPowerChassisDcPowerProblem
.1.3.6.1.4.1.232.0.22031
Power subsystem DC power problem.
There is a power subsystem DC power problem for this power enclosure.
User Action: Check the power enclosure and power supplies. Replace
any failed or degraded power supplies.
cpqRackPowerChassisAcFacilityPowerExceeded
.1.3.6.1.4.1.232.0.22032
Power subsystem AC facility input power exceeded.
There is a power subsystem Power subsystem AC facility input power
exceeded for this power enclosure.
User Action: Check the power enclosure and power supplies. Replace
any failed or degraded power supplies.
cpqRackPowerUnknownPowerConsumption
.1.3.6.1.4.1.232.0.22033
Unknown power consumption.
There is an unknown power consumer drawing power.
User Action: Check the power enclosure and power supplies. Replace
any failed or degraded power supplies.
cpqRackPowerChassisLoadBalancingWireMissing
.1.3.6.1.4.1.232.0.22034
Power subsystem load balancing wire missing.
The power subsystem load balancing wire missing.
User Action: Connect the load balancing wire.
cpqRackPowerChassisTooManyPowerChassis
.1.3.6.1.4.1.232.0.22035
Power subsystem has too may power enclosures.
The maximum number of power enclosures has been exceeded.
User Action: Remove the extra power enclosure.
cpqRackPowerChassisConfigError
.1.3.6.1.4.1.232.0.22036
Power subsystem improperly configured.
The power subsystem has been improperly configured.
User Action: Check the cabling of the power enclosure.
cpqRackEnclosureManagerDegraded
.1.3.6.1.4.1.232.0.22037
The Onboard Administrator or other management processor status has been set to degraded.
This trap signifies that either the Onboard Administrator(s) or its component(s) has degraded/failed,
their firmware versions are mismatched, or one or more management processors is in a non-optimal operating state.
User Action: For C-Class enclosures, please refer to the Onboard Administrator SYSLOG.
For all the others please refer to product documentation for possible corrective actions
cpqRackEnclosureManagerOk
.1.3.6.1.4.1.232.0.22038
The Onboard Administrator or other management processor's status has been set to ok.
This trap signifies that an Onboard Administrator or other management processor has returned
to normal operation.
User Action: None.
cpqRackEnclosureManagerRemoved
.1.3.6.1.4.1.232.0.22039
The Onboard Administrator has been removed.
User Action: None.
cpqRackEnclosureManagerInserted
.1.3.6.1.4.1.232.0.22040
The Onboard Administrator or other management processor has been inserted.
User Action: None.
cpqRackManagerPrimaryRole
.1.3.6.1.4.1.232.0.22041
The Onboard Administrator or other management processor has taken the role of primary.
User Action: None.
cpqRackServerBladeEKeyingFailed
.1.3.6.1.4.1.232.0.22042
The server blade e-keying has failed.
This trap signifies that a server blade e-keying has failed and
there is a port mapping problem between a server mezz card
and the interconnect.
User Action: Reconfigure server blade mezz cards.
cpqRackServerBladeEKeyingOK
.1.3.6.1.4.1.232.0.22043
The server blade e-keying is ok.
This trap signifies that a server blade e-keying has returned to
normal operation.
User Action: None.
cpqRackNetConnectorRemoved
.1.3.6.1.4.1.232.0.22044
Interconnect removed.
The interconnect has been removed from the enclosure.
User Action: None.
cpqRackNetConnectorInserted
.1.3.6.1.4.1.232.0.22045
Interconnect inserted.
The interconnect has been inserted into the enclosure.
User Action: None.
cpqRackNetConnectorFailed
.1.3.6.1.4.1.232.0.22046
The interconnect status has been set to failed.
This trap signifies that a interconnect has failed.
User Action: Replace the interconnect as soon as possible.
cpqRackNetConnectorDegraded
.1.3.6.1.4.1.232.0.22047
The interconnect status has been set to degraded.
This trap signifies that a interconnect has degraded.
User Action: Refer to the OA and the status diagnostics reported for the interconnect.
cpqRackNetConnectorOk
.1.3.6.1.4.1.232.0.22048
The interconnect status has been set to ok.
This trap signifies that a interconnect has returned to
normal operation.
User Action: None.
cpqRackServerBladeToLowPower
.1.3.6.1.4.1.232.0.22049
The server blade requested to low power.
User Action: None.
cpqRackServerBladeRemoved2
.1.3.6.1.4.1.232.0.22050
Server blade removed.
The server blade has been removed from the enclosure.
User Action: None.
cpqRackServerBladeInserted2
.1.3.6.1.4.1.232.0.22051
Server blade inserted.
The server blade has been inserted into the enclosure.
User Action: None.
cpqRackServerBladeStatusRepaired
.1.3.6.1.4.1.232.0.22052
Server blade repaired.
The server blade status has changed to OK.
User Action: None.
cpqRackServerBladeStatusDegraded
.1.3.6.1.4.1.232.0.22053
Server blade health status Degraded.
The server blade health status has changed to Degraded.
User Action: Check blade server and enclosure SYSLOG.
cpqRackServerBladeStatusCritical
.1.3.6.1.4.1.232.0.22054
Server blade health status Critical.
The server blade health status has changed to Critical.
User Action: Check blade server and enclosure SYSLOG.
cpqRackServerBladeGrpCapTimeout
.1.3.6.1.4.1.232.0.22055
The server blade is not responding to the group capper.
The server blade is not responding to capping requests from the enclosure group capper
User Action: Reset the iLO management processor.
cpqRackServerBladeUnexpectedShutdown
.1.3.6.1.4.1.232.0.22056
Server blade shutdown unexpectadly.
An unexpected shutdown event has occurred for this server blade.
User Action: Check blade server and enclosure SYSLOG.
Server blade's management controller firmware updating.
This server blade's management controller has started updating it's firmware.
User Action: None.
Server blade's management controller firmware update has completed.
This server blade's management controller has finished updating it's firmware.
User Action: None.
cpqRackServerBladeSystemBIOSFirmwareUpdating
.1.3.6.1.4.1.232.0.22059
Server blade's system BIOS firmware updating.
This server blade's system BIOS has started updating.
User Action: None.
Server blade's system BIOS firmware update complete.
This server blade's system BIOS has completed updating.
User Action: None.
cpqRackServerBladeFrontIOBlankingActive
.1.3.6.1.4.1.232.0.22061
Server blade has disabled front IO ports.
Front IO blanking status has changed to active for this server blade.
User Action: None.
cpqRackServerBladeRemoteFrontIOBlankingInactive
.1.3.6.1.4.1.232.0.22062
Server blade has front IO blanking mode now inactive.
Front IO blanking status has changed to inactive for this server blade.
User Action: None.
cpqRackServerBladeDiagnosticAdaptorInserted
.1.3.6.1.4.1.232.0.22063
Server blade diagnostic adaptor inserted.
Blade diagnostic adaptor status has changed to inserted for this server blade.
User Action: None.
cpqRackServerBladeDiagnosticAdaptorRemoved
.1.3.6.1.4.1.232.0.22064
Server blade diagnostic adaptor removed.
Blade diagnostic adaptor status has changed to removed for this server blade.
User Action: None.
cpqRackServerBladeEnteredPXEBootMode
.1.3.6.1.4.1.232.0.22065
Server blade has entered PXE Boot Mode.
Server blade Pre-Boot-eXecution (PXE) Mode started.
User Action: None.
cpqRackServerBladeExitedPXEBootMode
.1.3.6.1.4.1.232.0.22066
Server blade has exited PXE Boot Mode.
Server blade Pre-Boot-eXecution (PXE) Mode exited.
User Action: None.
cpqRackServerBladeWarmReset
.1.3.6.1.4.1.232.0.22067
Server blade has been warm reset.
Server blade has experienced a warm reset.
User Action: None.
cpqRackServerBladePOSTCompleted
.1.3.6.1.4.1.232.0.22068
Server blade system BIOS POST complete.
Server blade has completed system BIOS Power-On-Self-Test (POST).
User Action: None.
cpqRackServerBladePoweredOn
.1.3.6.1.4.1.232.0.22069
Server blade has powered on.
User Action: None.
cpqRackServerBladePoweredOff
.1.3.6.1.4.1.232.0.22070
Server blade has powered off.
User Action: None.
cpqRackInformationalEAETrap
.1.3.6.1.4.1.232.0.22071
EAE Informational trap
cpqRackMinorEAETrap
.1.3.6.1.4.1.232.0.22072
EAE Minor trap
cpqRackMajorEAETrap
.1.3.6.1.4.1.232.0.22073
EAE Major trap
cpqRackCriticalEAETrap
.1.3.6.1.4.1.232.0.22074
EAE Critical trap
cpqRackPowerMinorEAETrap
.1.3.6.1.4.1.232.0.22075
FlexFabric Cmdr Power Subsystem Minor trap.
User Action: For FlexFabric Cmdr, please refer to product documentation for
possible corrective actions.
cpqRackPowerMajorEAETrap
.1.3.6.1.4.1.232.0.22076
FlexFabric Cmdr Power Subsystem Major trap.
User Action: For FlexFabric Cmdr, please refer to product documentation for
possible corrective actions.
cpqRackPowerCriticalEAETrap
.1.3.6.1.4.1.232.0.22077
FlexFabric Cmdr Power Subsystem Critical trap.
User Action: For FlexFabric Cmdr, please refer to product documentation for
possible corrective actions.
cpqRackServerBladePartitionChange
.1.3.6.1.4.1.232.0.22078
Server Blade Partition Changed trap.
The server blade is part of a conjoined blade and its partition has changed.
User Action: None.
cpqRackInformationalWSMANTrap
.1.3.6.1.4.1.232.0.22079
WSMAN Informational trap
cpqRackMinorWSMANTrap
.1.3.6.1.4.1.232.0.22080
WSMAN Minor trap
cpqRackMajorWSMANTrap
.1.3.6.1.4.1.232.0.22081
WSMAN Major trap
cpqRackCriticalWSMANTrap
.1.3.6.1.4.1.232.0.22082
WSMAN Critical trap
cpqRackEnclosureManagerLinkDown
.1.3.6.1.4.1.232.0.22083
The Onboard Administrator Network Link is Down.
The Onboard Administrator firmware has detected the loss of network link.
User Action: Check network connection and configurations for the Onboard Administrator.
cpqRackEnclosureManagerLinkUp
.1.3.6.1.4.1.232.0.22084
The Onboard Administrator Network Link is Up.
The Onboard Administrator firmware has detected the presence of network link.
User Action: None.
cpqRackErsCommFailure
.1.3.6.1.4.1.232.0.22085
The Onboard Administrator to Insight Remote Support or Insight Online communication failed.
User Action: Please check the connectivity to Insight Remote Support or Insight Online.
cpqRackPowerSubsystemOverloadConditionRepaired
.1.3.6.1.4.1.232.0.22086
The rack power subsystem overload condition repaired.
cpqRackPowerSubsystemRedundancyOk
.1.3.6.1.4.1.232.0.22087
The rack power subsystem is now redundant.
This trap signifies that the enclosure power subsystem redundancy is now restored.
User Action : None.
cpqRackNetConnectorTempDegraded
.1.3.6.1.4.1.232.0.22088
The Interconnect temperature status has been set to degraded.
This trap signifies that an interconnect temperature sensor has
been tripped indicating a possible overheat condition.
User Action: Refer to the OA and the status diagnostics reported for the interconnect.
cpqRackNetConnectorTempOk
.1.3.6.1.4.1.232.0.22089
The interconnect temperature status has been set to ok.
This trap signifies that an interconnect temperature sensor has
returned to normal.
User Action: None.
cpqRackEnvironmentalLeakDetected
.1.3.6.1.4.1.232.0.22090
A leak was detected by one or more leak detect sensors in the rack